Refine Results
- Product Category
- Application & Industry Category
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
-
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
An ultrasensitive method has been developed for simultaneous determination of perfluorooctane sulfonates (PFOS) and perfluorooctanoic acid (PFOA) in food
- Publication Part Number: 5991-1948EN
- Created: May 26, 2016
- File Size: 398 KB
- English
| Publication Part Number | 5991-1948EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
The fast and reproducible sample preparation capability of Agilent Captiva ND Lipids plates is shown in an analysis of plant polyphenols.
- Publication Part Number: 5991-1999EN
- Created: August 15, 2015
- File Size: 167 KB
- English
| Publication Part Number | 5991-1999EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Steroidal saponins in two species of yams are characterized by high resolution accurate mass measurement MS/MS and the MS is used to differentiate the two species.
- Publication Part Number: 5991-4540EN
- Created: December 17, 2014
- File Size: 600 KB
- English
| Publication Part Number | 5991-4540EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Demostration that stringent sensitivity requirements for the detection of potentially harmful primary aromatic amines can be fulfilled.
- Publication Part Number: 5990-9751EN
- Created: September 15, 2014
- File Size: 487 KB
- English
| Publication Part Number | 5990-9751EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
The sensitivity of UHPLC/MS method on an 6150 Series Single Quadrupole LC/MS was demonstrated for the application of cleaning verification studies of highly potent drugs.
- Publication Part Number: 5991-4509EN
- Created: June 1, 2014
- File Size: 1 MB
- English
| Publication Part Number | 5991-4509EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
This Application Note describes the analysis of hydrophilic phenolic compounds in olive oil samples, using both HPLC and UHPLC with ternary gradients on the Agilent 1260 Infin
- Publication Part Number: 5991-3801EN
- Created: May 1, 2014
- File Size: 836 KB
- English
| Publication Part Number | 5991-3801EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
A method and workflow by combination of Agilent UHPLC-ESI/Q-TOF MS and MPP software has been presented for metabolomics profiling of wines produced from France and China.
- Publication Part Number: 5991-3335EN
- Created: March 20, 2014
- File Size: 995 KB
- English
| Publication Part Number | 5991-3335EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
A method on simultaneous determination of eight mycotoxins in wines has been developed based on QQQ6460 LCMS platform with high sensitivity and accuracy.
- Publication Part Number: 5991-3337EN
- Created: November 26, 2013
- File Size: 208 KB
- English
| Publication Part Number | 5991-3337EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Peptide mapping is the common analytical technique for characterizing biologic therapeutic proteins.
- Publication Part Number: 5991-3600EN
- Created: November 22, 2013
- File Size: 1 MB
- English
| Publication Part Number | 5991-3600EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Successful validation of a highly sensitive and accurate method for the quantitation of mycotoxins regulated in Europe for cereal based food products by UHPLC/MS/MS
- Publication Part Number: 5991-2808EN
- Created: October 14, 2013
- File Size: 283 KB
- English
| Publication Part Number | 5991-2808EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Determination of nonregulated herbicide metabolites in water with a customized Agilent 1200 Infinity Series Online SPE System.
- Publication Part Number: 5991-2776EN
- Created: September 1, 2013
- File Size: 2 MB
- English
| Publication Part Number | 5991-2776EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Development of analysis method for phthalates using the Agilent 1290 Infinity Method Development Solution with a phenyl-hexyl column.
- Publication Part Number: 5991-2784EN
- Created: September 1, 2013
- File Size: 2 MB
- English
| Publication Part Number | 5991-2784EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
Analysis of squalene in olive oil samples with HPLC and UHPLC methods using the Agilent 1220 Infinity Mobile LC Solution.
- Publication Part Number: 5991-2774EN
- Created: August 1, 2013
- File Size: 322 KB
- English
| Publication Part Number | 5991-2774EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
A comparison of the separation and sequence coverage of glycoproteins by reversed-phase and HILIC demonstrates the utility of HILIC.
- Publication Part Number: 5991-2085EN
- Created: May 10, 2013
- File Size: 407 KB
- English
| Publication Part Number | 5991-2085EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Korean (Korea) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Using the 1290 Infinity LC System coupled with the ZORBAX Eclipse Plus 3 × 100 mm, 1.8 μm column not only reduces solvent consumption, but allows for greater peak resolution.
- Publication Part Number: 5991-1971EN
- Created: May 6, 2013
- File Size: 1 MB
- English
| Publication Part Number | 5991-1971EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Development and validation of a target MS/MS method for the screening, verification and quantitation of pesticides in fruit and vegetables by UHPLC and 6540 UHD QTOF LC/MS.
- Publication Part Number: 5991-2227EN
- Created: April 24, 2013
- File Size: 2 MB
- English
| Publication Part Number | 5991-2227EN | |||||
|---|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||||
| Instrument |
|
|||||
| Analytical Technique | Technique |
|
||||
| Injection |
|
|||||
| Detection |
|
|||||
| Sample | Chemical Group |
|
||||
| Sample Matrix |
|
Analysis of counterfeit antidiabetic sulfonylurea-class drugs using Agilent 1220 Infinity Gradient LC with diode array detector.
- Publication Part Number: 5991-2177EN
- Created: April 1, 2013
- File Size: 693 KB
- English
| Publication Part Number | 5991-2177EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
Complementary SFC and UHPLC analysis of antioxidants in vegetable oil samples using the 1260 Infinity Hybrid SFC/UHPLC System with mass spectrometry detection.
- Publication Part Number: 5991-1546EN
- Created: February 15, 2013
- File Size: 2 MB
- English
| Publication Part Number | 5991-1546EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
A UHPLC method was developed for the simultaneous determination in nine minutes of nine preservatives often used in food and beverages using a Poroshell 120 EC-C18 column.
- Publication Part Number: 5991-1898EN
- Created: February 15, 2013
- File Size: 1 MB
- English
| Publication Part Number | 5991-1898EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This Application Note describes the conversion of the USP normal-phase HPLC method for cholecalciferol assay to an SFC method using serially coupled columns.
- Publication Part Number: 5991-1456EN
- Created: December 1, 2012
- File Size: 751 KB
- English
| Publication Part Number | 5991-1456EN | ||||
|---|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|||
| Instrument |
|
||||
| Analytical Technique | Technique |
|
|||
| Injection |
|
||||
| Detection |
|
||||
| Sample | Chemical Group |
|
|||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|