Refine Results
- Product Category
- Application & Industry Category
-
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Features of the MP Expert software
- Publication Part Number: 5990-8975EN
- Created: September 1, 2016
- File Size: 2 MB
- English
| Publication Part Number | 5990-8975EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
Application note for Determination of metals in wine using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer
- Publication Part Number: 5991-1586EN
- Created: March 11, 2015
- File Size: 578 KB
- English
| Publication Part Number | 5991-1586EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Spanish (Spain) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
Determination of silicon in diesel and biodiesel by Microwave Plasma-Atomic Emission Spectrometry
- Publication Part Number: 5991-0490EN
- Created: February 14, 2014
- File Size: 73 KB
- English
| Publication Part Number | 5991-0490EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Portuguese (United States) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
Application note for the analysis of Chinese herbal medicines by microwave plasma-atomic emission spectrometry (MP-AES)
- Publication Part Number: 5990-9791EN
- Created: February 13, 2014
- File Size: 160 KB
- English
| Publication Part Number | 5990-9791EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Portuguese (Brazil) | Complete (PDF) |
|---|---|
| Russian (Russia) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
Application note for the analysis of diesel
- Publication Part Number: 5990-9005EN
- Created: February 12, 2014
- File Size: 184 KB
- English
| Publication Part Number | 5990-9005EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for the analysis of wear metals and contaminants in engine oils
- Publication Part Number: 5990-8753EN
- Created: February 12, 2014
- File Size: 133 KB
- English
| Publication Part Number | 5990-8753EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for new methodology for determination of gold and precious metals
- Publication Part Number: 5990-8597EN
- Created: February 12, 2014
- File Size: 392 KB
- English
| Publication Part Number | 5990-8597EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for Analysis of major elements in fruit juices using the Agilent 4200 MP-AES with the Agilent 4107 Nitrogen Generator
- Publication Part Number: 5991-3613EN
- Created: January 6, 2014
- File Size: 610 KB
- English
| Publication Part Number | 5991-3613EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for Determination of major and minor elements in geological samples using the 4200 MP-AES
- Publication Part Number: 5991-3772EN
- Created: January 5, 2014
- File Size: 2 MB
- English
| Publication Part Number | 5991-3772EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note for Analysis of aluminum in beverages using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer (MP-AES)
- Publication Part Number: 5991-2094EN
- Created: August 5, 2013
- File Size: 945 KB
- English
| Publication Part Number | 5991-2094EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
Application note for Direct analysis of milk using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer (MP-AES)
- Publication Part Number: 5991-2071EN
- Created: July 8, 2013
- File Size: 450 KB
- English
| Publication Part Number | 5991-2071EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer
- Publication Part Number: 5991-0048EN
- Created: April 17, 2013
- File Size: 720 KB
- English
| Publication Part Number | 5991-0048EN | |||
|---|---|---|---|---|
| Analysis | Analysed with Part No. |
|
||
| Instrument |
|
|||
| Analytical Technique | Technique |
|
||
| Injection |
|
|||
| Detection |
|
|||
| Sample | Chemical Group |
|
||
| Sample Matrix |
|
This application note describes a new method for the measurement of additives in lubricating oils.
- Publication Part Number: 5990-8925EN
- Created: October 11, 2012
- File Size: 785 KB
- English
| Publication Part Number | 5990-8925EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
Application note explaining a technique for determining the concentration of base metals in mining ores.
- Publication Part Number: 5990-9014EN
- Created: September 26, 2012
- File Size: 122 KB
- English
| Publication Part Number | 5990-9014EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Detailing techniques for the determination of metals in industrial wastewaters by microwave plasma-atomic emission spectrometry.
- Publication Part Number: 5990-8673EN
- Created: September 26, 2012
- File Size: 280 KB
- English
| Publication Part Number | 5990-8673EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Japanese (Japan) | Complete (PDF) |
|---|---|
| Chinese (Simplified) (China) | Complete (PDF) |
Application note for Direct analysis of Cr, Ni, Pb and V in ethanol fuel by Microwave Plasma-Atomic Emission Spectrometry
- Publication Part Number: 5991-0771EN
- Created: August 3, 2012
- File Size: 152 KB
- English
| Publication Part Number | 5991-0771EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Portuguese (Brazil) | Complete (PDF) |
|---|---|
| Japanese (Japan) | Complete (PDF) |
| Chinese (Simplified) (China) | Complete (PDF) |
- Publication Part Number: 5990-8975EN
- Created: November 16, 2011
- File Size: 402 KB
- English
| Publication Part Number | 5990-8975EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
4200 微波等离子体原子发射光谱仪 (MP-AES) 测定米粉中的常量、微量和痕量元素
- Publication Part Number: 5991-3777CHCN
- Created: April 21, 2014
- File Size: 437 KB
- Chinese (Simplified)
| Publication Part Number | 5991-3777EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
- Publication Part Number: 5990-8685JAJP
- Created: November 9, 2011
- File Size: 610 KB
- Japanese
| Publication Part Number | 5990-8685EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|
| Chinese (Simplified) (China) | Complete (PDF) |
|---|
- Publication Part Number: 5990-8914JAJP
- Created: November 9, 2011
- File Size: 802 KB
- Japanese
| Publication Part Number | 5990-8914EN | ||
|---|---|---|---|
| Analysis | Analysed with Part No. |
|
|
| Instrument |
|
||
| Analytical Technique | Technique |
|
|
| Injection |
|
||
| Detection |
|
||
| Sample | Chemical Group |
|
|
| Sample Matrix |
|