GC Column Cross Reference

Upgrade to an Agilent J&W GC Column

If you are using a Supelco GC column and would like to upgrade to an Agilent J&W column, this GC column cross-reference guide will make your conversion easy. Each section of this guide lists, by phase selection, the suggested Agilent J&W upgrade from Supelco's columns. 

This is not, however, a complete listing, but represents only the most frequently used columns. If you do not find the column you are currently using and would like to upgrade to an Agilent J&W column, call our Technical Support staff, free of charge, for assistance at 800-227-9770 or outside of North America call 916-985-7888 or e:mail us.

Tip: To find the Agilent upgrade  for the Supelco phase or part number you are currently using, select the "Find" function from your internet browser "Edit" menu.

Supelco Phase Supelco P/N Length (m) I.D. (mm) Film (Ám)

Agilent J&W Equivalent

Agilent J&W P/N

Notes

b-DEX 110 24301 30 0.25 0.25

Cyclodex-B

112-2532 Same chiral selector embedded in a cyanopropylphenyl phase
b-DEX 110 24302 60 0.25 0.25 Cyclodex-B 112-2562 Same chiral selector embedded in a cyanopropylphenyl phase
b-DEX 120 24304 30 0.25 0.25 HP-Chiral 20B 19091G-B233  
b-DEX 325 24308 30 0.25 0.25 CycloSil-B  112-6632 Same chiral selector embedded in a cyanopropylphenyl phase
Carbowax Amine 25352 15 0.53 1.00 CAM 115-2112  
Carbowax Amine 25353 30 0.53 1.00 CAM 115-2132  
Carbowax Amine 25354 60 0.53 1.00 CAM 115-2162  
Carboxen-1006 PLOT 25461 30 0.53 NA GS-CarbonPLOT 115-3133  
Carboxen-1006 PLOT 24241-U 30 0.32 NA GS-CarbonPLOT 113-3132  
Carboxen-1010 PLOT 24246 30 0.32 NA GS-CarbonPLOT 113-3132  
Carboxen-1010 PLOT 25467 30 0.53 NA GS-CarbonPLOT 115-3133  
Deactivated Guard Column for OVI-G43  25339 5 0.53 N/A Deactivated F.S. Tubing 160-2535-5  
HT-5 25002 12 0.32 0.10 DB-5ht 123-5711 Slightly different dimensions
HT-5 25003 25 0.32 0.10 DB-5ht 123-5731 Slightly different dimensions
MDN-1 24258 30 0.25 0.25 DB-1ms 122-0132  
MDN-1 24259 30 0.25 1.00 DB-1 122-1033  
MDN-1 24299 30 0.32 0.25 DB-1ms 123-0132  
MDN-1 24300-U 30 0.32 1.00 DB-1 123-1033  
MDN-5 24096 30 0.25 0.25 DB-5
HP-5
122-5032
19091J-433
 
MDN-5 24097 30 0.32 0.25 DB-5
HP-5
123-5032
19091J-413
 
MDN-5 24203 30 0.32 0.32 DB-5
HP-5
100-2000
100-2000
 
MDN-5 24204-U 30 0.32 1.00 DB-5
HP-5
123-5033
19091J-213
 
MDN-5S 24378 30 0.25 0.10 DB-5ms 122-5531  
MDN-5S 24377-U 15 0.25 0.25 DB-5ms 122-5512  
MDN-5S 24384 30 0.25 0.25 DB-5ms 122-5532  
MDN-5S 24392 60 0.25 0.25 DB-5ms 122-5562  
MDN-5S 24379 30 0.25 0.50 DB-5ms 122-5536  
MDN-5S 24385-U 30 0.25 1.00 DB-5ms 122-5533  
MDN-5S 24386 30 0.32 0.25 DB-5ms 122-5532  
MDN-5S 24394 60 0.32 0.25 DB-5ms 123-5562  
MDN-5S 24393 30 0.32 0.50 DB-5ms 122-5536  
MDN-5S 24387-U 30 0.32 1.00 DB-5ms 123-5533  
MDN-5S 25474 30 0.53 1.50 DB-5ms 125-5532  
MDN-12 24388 30 0.25 0.25 DB-XLB 122-1232  
MDN-12 24396 60 0.25 0.25 DB-XLB 122-1262  
MDN-12  24395 30 0.25 0.50 DB-XLB 122-1236  
MDN-12 24389 30 0.25 1.00 DB-XLB 122-1233  
MDN-12 24390-U  30 0.32 0.25 DB-XLB 123-1232  
MDN-12 24398 60 0.32 0.25 DB-XLB 123-1262  
MDN-12  24397 30 0.32 0.50 DB-XLB  123-1236  
MDN-12 24391 30 0.32 1.00 DB-XLB 123-1233  
MDN-35  24382-U 30 0.25  0.25 DB-35ms 122-3832  
MDN-35 24383-U 30 0.32 0.25 DB-35ms 123-3832  
MET-1 25473 15 0.53 1.50 DB-PS1 145-1012  
MET-1 25477 30 0.53 0.50 DB-PS1 145-1037  
MET-1 25478 30 0.53 3.00 DB-PS1 145-1034  
MET-1 25487 15 0.53 0.50 DB-PS1 145-1017  
MET-1 25488 30 0.53 1.50 DB-PS1 145-1032  
MET-1 25489 30 0.53 5.00 DB-PS1 145-1035  
MET-5 25482 30 0.53 1.50 DB-PS5 145-5032  
MET-WAX 25484 15 0.53 1.00 DB-PSWAX 145-7012  
MET-WAX 25485 30 0.53 1.00 DB-PSWAX 145-7032  
Mol Sieve 5A PLOT 24243 30 0.32 NA HP-PLOT MoleSieve 19091P-MS4  
Mol Sieve 5A PLOT 25463 30 0.53 NA HP-PLOT MoleSieve 19095P-MS6  
NUKOL 24107 30 0.25 0.25 DB-FFAP
HP-FFAP
122-3232
19091F-433
 
NUKOL 24108 60 0.25 0.25 DB-FFAP 122-3262  
NUKOL 24130 15 0.32 0.25 DB-FFAP
HP-FFAP
123-3212
19091F-411
 
NUKOL 24131 30 0.32 0.25 DB-FFAP
HP-FFAP
123-3232
19091F-413
 
NUKOL 24132 60 0.32 0.25 DB-FFAP 123-3262  
NUKOL 24207 30 0.32 1.00 DB-FFAP 123-3234  
NUKOL 24208 60 0.32 1.00 DB-FFAP 123-3264  
NUKOL 25326 15 0.53 0.50 DB-FFAP 125-3217  
NUKOL 25327 30 0.53 0.50 DB-FFAP 125-3237  
NUKOL 25386 60 0.53 0.50 DB-FFAP 100-2000  
NUKOL 24106-U 15 0.25 0.25 DB-FFAP
HP-FFAP
122-3212
19091F-431
 
NUKOL 24206-U 15 0.32 1.00 DB-FFAP 123-3214  
Omegawax 250 24136 30 0.25 0.25 DB-WAXetr
HP-INNOWax
122-7332  19091N-133  
Omegawax 320 24152 30 0.32  0.25 DB-WAXetr
HP-INNOWax
123-7332  19091N-113  
Omegawax 530 25374 30 0.53 0.50 DB-WAXetr 100-2000  
Petrocol DH 50.2  24133-U 50  0.20  0.50 DB-Petro50
HP-PONA
128-1056
19091S-001
 
Petrocol DH 24160-U 100 0.25 0.50 DB-Petro100
HP-1
122-10A6  19091Z-530  
Petrocol 2887 25323 5 0.53 0.50 DB-HTSimDis 145-1001  
PTA-5  24277 30 0.25 0.50  DB-5 122-503E  
PTA-5  24330 30  0.25 1.00  DB-5 122-5033  
PTA-5 24331 30 0.32  0.50  DB-5 123-503E  
PTA-5  24332 30  0.32 1.00  DB-5 123-5033  
PTA-5  24333 30  0.32 1.50  DB-5 123-503B  
PTA-5  25437 30  0.53 0.50  DB-5 125-5037  
PTA-5  25438  30  0.53  1.50  DB-5 125-5032  
PTA-5 25439 30 0.53 3.00  DB-5 125-5034  
PTE-5 24135-U 30 0.25 0.25 DB-5ms
HP-5ms
122-5532  19091S-433  
PTE-5 24143  30 0.32 0.25 DB-5ms
HP-5ms
123-5532  19091S-413  
PTE-5 24159 30 0.32 1.00 DB-5ms
HP-5ms
123-5533  19091S-213  
PTE-5QTM 25355 15  0.53 0.50 DB-5ms 125-5017  
SE-30 24004-U 30 0.25 0.25 SE30 112-3032  
SE-54 24001 30 0.25 0.25 SE-54 112-5432  
SP-2250 24009 15 0.25 0.20 DB-17
HP-50+
122-1712
19091L-431
Bonded phase instead of non-bonded, 0.25um instead of 0.20um
SP-2250 24010 30 0.25 0.20 DB-17
HP-50+
122-1732
19091L-433
Bonded phase instead of non-bonded, 0.25um instead of 0.20um
SP-2250 24011-U 60 0.25 0.20 DB-17
HP-50+
122-1762
19091L-436
Bonded phase instead of non-bonded, 0.25um instead of 0.20um
SP-2250 24147 15 0.32 0.20 DB-17
HP-50+
123-1712
19091L-411
Bonded phase instead of non-bonded, 0.25um instead of 0.20um
SP-2250 24148 30 0.32 0.20 DB-17
HP-50+
122-1732
19091L-413
Bonded phase instead of non-bonded, 0.25um instead of 0.20um
SP-2331 24257 30 0.25  0.20 DB-Dioxin 100-2000  
SP-2331 24104-U 60 0.25 0.20 DB-Dioxin 122-2462  
SP-2331 24105 60 0.32  0.20 DB-Dioxin 123-2461  
SPB-608 24103-U 30  0.25 0.25 DB-608 122-6832  
SPB-608 25312 30 0.53 0.50 DB-608 125-6837  
SPB-624 24255 30 0.25 1.40 DB-624 122-1334  
SPB-624 24256 60 0.25 1.40 DB-624 122-1364  
SPB-624 24251 60 0.32 1.80 DB-624 123-1364  
SPB-624 25430 30  0.53 3.00 DB-624 125-1334  
SPB-624 25432 75  0.53 3.00 DB-624 125-1374  
SPB-HAP 25020-U 60  0.32 4.00 DB-1 100-2000  
SAC-5  24151 15 0.25  0.25 DB-5ms
HP-5ms
122-5512  19091S-431  
SAC-5 24156 30 0.25 0.25 DB-5ms
HP-5ms
122-5532  19091S-433  
SPB-1 Sulfur 24158 30 0.32 4.00  HP-1 19091Z-613  
OVI-G43 25396 30 0.53 3.00 DB-624 125-1334  
SPB-5 25339 30 0.53 5.00 DB-5
HP-5
125-5035  19095J-623  
SPB-1 25360 15 0.53 0.10 DB-1 125-1011 Slightly different dimensions
SPB-1 24338 15 0.10 0.10 DB-1 127-1022 Slightly different dimensions
SPB-1 24162 15 0.20 0.20 DB-1 128-10H7  
SPB-1 24299-U 12 0.20  0.33 DB-1
 HP-1
 128-1012 19091-60312  
SPB-1 24230-U 25 0.20 0.33 DB-1
HP-1
128-1022
19091Z-331
 
SPB-1 24261 30 0.25 0.10 DB-1
HP-1
122-1031  19091Z-333  
SPB-1 24026 15 0.25 0.25 DB-1
HP-1
122-1012  19091Z-431  
SPB-1 24028 30 0.25 0.25 DB-1
HP-1
122-1032  19091Z-433  
SPB-1 24030-U 60 0.25  0.25 DB-1
HP-1
122-1062  19091Z-436  
SPB-1 24198 100 0.25 0.25 DB-1 100-2000  
SPB-1 24027 15 0.25 1.00 DB-1
HP-1
122-1013  19091Z-231  
SPB-1 24029 30 0.25 1.00 DB-1
HP-1
122-1033  19091Z-233  
SPB-1 24031 60 0.25 1.00 DB-1
HP-1
122-1063  19091Z-236  
SPB-1 24220-U 100 0.25  1.00 DB-1 100-2000  
SPB-1 24290 30 0.32 0.10 DB-1
HP-1
123-1031  19091Z-313  
SPB-1 24099 15 0.32 0.25 DB-1
HP-1
123-1012 19091Z-411  
SPB-1 24044 30 0.32 0.25 DB-1
HP-1
123-1032  19091Z-413  
SPB-1 24046 60 0.32 0.25 DB-1
HP-1
123-1062  19091Z-416  
SPB-1 24228-U 100 0.32 0.25 DB-1 100-2000  
SPB-1 24098-U 15 0.32 1.00 DB-1
HP-1
 123-1013  19091Z-211  
SPB-1 24045-U 30 0.32 1.00  DB-1
HP-1
123-1033 19091Z-213  
SPB-1 24047 60 0.32 1.00 DB-1
HP-1
123-1063  19091Z-216  
SPB-1 24213-U 100 0.32  1.00 DB-1 100-2000  
SPB-1 24215-U 30 0.32 2.00 DB-1 123-103G  
SPB-1 24216-U 60 0.32 2.00 DB-1 123-106G  
SPB-1 24296 30 0.32 5.00 DB-1
HP-1
123-1035  19091Z-713  
SPB-1 24297 60 0.32  5.00 DB-1
HP-1
123-1065 19091Z-716  
SPB-1 25361 30 0.53 0.10 DB-1 125-1039  
SPB-1 25314 15 0.53 0.20 DB-1 100-2000  
SPB-1 25315 30 0.53  0.20 DB-1 100-2000  
SPB-1 25382 60 0.53 0.20 DB-1 100-2000  
SPB-1 25416 15 0.53 1.00 DB-1  125-101J  
SPB-1 25417 30 0.53 1.00 DB-1 125-103J  
SPB-1 25302-U 15   0.53 1.50 DB-1
HP-1
125-1012  19095Z-321  
SPB-1 25303 30 0.53  1.50 DB-1
HP-1
125-1032  19095Z-323  
SPB-1 25388 60 0.53 1.50 DB-1   125-1062  
SPB-1 25340 15 0.53 3.00 DB-1
HP-1
125-1014 19095Z-421  
SPB-1 25341-U 30 0.53 3.00 DB-1
HP-1
125-1034 19095Z-423  
SPB-1 25348 60 0.53 3.00 DB-1  125-1064  
SPB-1 25344 15 0.53 5.00 DB-1
HP-1
125-1015 19095Z-621  
SPB-1 25345-U 30 0.53 5.00 DB-1
HP-1
 125-1035  19095Z-623  
SPB-1 25349 60 0.53 5.00 DB-1
HP-1
125-1065  19095Z-626  
SPB-5 24165-U 15 0.20 0.20  DB-5  128-50H7  
SPB-5 24166 30 0.20 0.20 DB-5 100-2000  
SPB-5   12 0.20 0.33 DB-5
HP-5
128-5012  19091J-101  
SPB-5 24032 15 0.25 0.25 DB-5
HP-5
122-5012 19091J-431  
SPB-5 24034 30 0.25 0.25 DB-5
HP-5
 122-5032 19091J-433  
SPB-5 24036 60 0.25 0.25 DB-5
HP-5
 122-5062 19091J-436  
SPB-5 24033 15 0.25 1.00 DB-5
HP-5
 122-5013 19091J-231  
SPB-5 24035 30 0.25 1.00  DB-5
HP-5
122-5033  19091J-233  
SPB-5 24037 60 0.25 1.00 DB-5
HP-5
 122-5063 19091J-236  
SPB-5   15 0.32 0.25 DB-5
HP-5
123-5012 19091J-411  
SPB-5 24048 30 0.32  0.25 DB-5
HP-5
123-5032 19091J-413  
SPB-5 24050 60 0.32 0.25 DB-5
HP-5
122-5062  19091J-416  
SPB-5 24360 30 0.32 0.50 DB-5
HP-5
123-503E  19091J-113  
SPB-5   15 0.32 1.00 DB-5
HP-5
123-5013 19091J-211  
SPB-5 24049 30 0.32  1.00 DB-5
HP-5
123-5032 19091J-213  
SPB-5 24051 60 0.32 1.00 DB-5
HP-5
123-5063  19091J-216  
SPB-5 25304 15 0.53 1.50 DB-5
HP-5
125-5012  19095J-321  
SPB-5 25316 15 0.53 0.50 DB-5   125-5017  
SPB-5 25317 30 0.53 0.50 DB-5  125-5037  
SPB-5 24341 15 0.10 0.10 DB-5 127-5022 Slightly different dimensions
SPB-5  25342 15 0.53 3.00 DB-5  100-2000  
SPB-5 25343 30 0.53 3.00 DB-5 125-5034  
SPB-5 25346 15 0.53 5.00 DB-5
HP-5
125-5015  19095J-621  
SPB-5  25347 30 0.53 5.00 DB-5
HP-5
 125-5035  19095J-623  
SPB-5 25350 60 0.53 3.00 DB-5  100-2000  
SPB-5 25351 60 0.53 5.00 DB-5 125-5065  
SPB-5 25383 60 0.53 0.50 DB-5  100-2000  
SPB-5   30 0.53 1.00 DB-5 125-503J  
SPB-5   30 0.53 1.50 DB-5
HP-5
125-5032  19095J-323  
SPB-5 25389 60 0.53 1.50 DB-5  125-5062  
SPB-17 24376 30 0.32 0.50 DB-17
HP-50+
123-1733
19091L-113
 
SPB-17 24381 30 0.32 0.25 DB-17
HP-50+
123-1732
19091L-413
 
SPB-17 25472 15 0.53 1.00 DB-17
HP-50+
125-1712
19095L-021
 
SPB-17 24374-U 15 0.25 0.25 DB-17
HP-50+
122-1712
19091L-431
 
SPB-17 24380-U 30 0.25 0.25 DB-17
HP-50+
122-1732
19091L-433
 
SPB-35 24092 30 0.25 0.25 DB-35
HP-35
122-1932  19091G-133  
SPB-35 24094 30  0.32 0.25 DB-35
HP-35
  123-1932  19091G-113  
SPB-35 25331 30 0.53 0.50 DB-35
HP-35
125-1937 19095G-523  
SPB-35 25335 30 0.53  1.00 DB-35
HP-35
125-1932 19095G-123  
SPB-50 24181 30 0.25 0.25 DB-17
HP-50+
122-1732 19091L-433  
SPB-50 24187 30 0.32 0.25 DB-17
HP-50+
123-1732  19091L-413  
SPB-50 25363 30 0.53  0.50 DB-17
HP-50+
125-1737  19095L-523  
SPB-225 24334 30 0.25 0.15 DB-225 122-2231  
SPB-225 24335 30 0.25 0.25 DB-225 122-2232  
SPB-225 24336 30 0.32 0.15 DB-225 123-2231  
SPB-225 24337 30 032 0.25 DB-225 123-2232  
SPB-1000 24313 30 0.25 0.25 DB-FFAP
HP-FFAP
122-3232
19091F-433
 
SPB-1000 24315 30 0.32 0.25 DB-FFAP
HP-FFAP
123-3232
19091F-413
 
SPB-1000 25445 30 0.53 0.50 DB-FFAP 125-3237  
SPB-1701 24112 15 0.25 0.25 DB-1701 122-0712  
SPB-1701 24113 30 0.25  0.25 DB-1701 122-0732  
SPB-1701 24114 60 0.25 0.25 DB-1701 122-0762  
SPB-1701 24183 15 0.32 0.25 DB-1701 123-0712  
SPB-1701 24184 30 0.32 0.25 DB-1701 123-0732  
SPB-1701 24185 60 0.32 0.25 DB-1701 123-0762  
SPB-1701 25368 15 0.53 0.50 DB-1701 125-0717  
SPB-1701 25369 30 0.53 0.50 DB-1701 125-0737  
SPB-1701 25366 15  0.53 1.00 DB-1701  125-0712  
SPB-1701 25367 30 0.53 1.00 DB-1701 125-0732  
SUPELCOWAX 10 24077 15 0.25 0.25 DB-WAXetr
HP-INNOWax
122-7312  19091N-131  
SUPELCOWAX 10 24078 15 0.32 0.25 DB-WAXetr
HP-INNOWax
123-7312
19091N-111
 
SUPELCOWAX 10 24079 30 0.25 0.25 DB-WAXetr
HP-INNOWax
122-7332  19091N-133  
SUPELCOWAX 10 24081 60 0.25 0.25 DB-WAXetr
HP-INNOWax
122-7362
19091N-136
 
SUPELCOWAX 10 24082 60 0.32 0.25 DB-WAXetr
HP-INNOWax
122-7362
19091N-116
 
SUPELCOWAX 10 24083 15 0.32 0.50 DB-WAXetr
HP-INNOWax
123-7313
19091N-211
 
SUPELCOWAX 10 24084 30 0.32 0.50 DB-WAXetr
HP-INNOWax
123-7333
19091N-213
 
SUPELCOWAX 10 24169 30 0.20 0.20 DB-WAXetr
HP-INNOWax
100-2000
19091N-102
Different dimensions
SUPELCOWAX 10 24170 60 0.20 0.20 DB-WAXetr
HP-INNOWax
100-2000
19091N-105
Different dimensions
SUPELCOWAX 10 24211 30 0.32 1.00 DB-WAXetr 123-7334  
SUPELCOWAX 10 24212 60 0.32 1.00 DB-WAXetr 123-7364  
SUPELCOWAX 10 24284 30 0.25 0.50 DB-WAXetr
HP-INNOWax
122-7333
 19091N-233
 
SUPELCOWAX 10 25324 15 0.53 0.50 DB-WAXetr 100-2000  
SUPELCOWAX 10 25325 30 0.53 0.50 DB-WAXetr 100-2000  
SUPELCOWAX 10 24343 15 0.10 0.10 DB-WAXetr 100-2000  
SUPELCOWAX 10 25376 60 0.53 2.00 DB-WAXetr 100-2000  
SUPELCOWAX 10 25385 60 0.53 0.50 DB-WAXetr 100-2000  
SUPELCOWAX 10 25391 60 0.53 1.00 DB-WAXetr
HP-INNOWax
125-7362
19095N-126
 
SUPELCOWAX 10 24080-U 30 0.32 0.25 DB-WAXetr
HP-INNOWax
123-7332
19091N-113
 
SUPELCOWAX 10 24085-U 60 0.32 0.50 DB-WAXetr
HP-INNOWax
123-7363
19091N-216
 
SUPELCOWAX 10 25025-U 5 0.10 0.10 DB-WAXetr 100-2000  
SUPELCOWAX 10 25026-U 10 0.10 0.10 DB-WAXetr 100-2000  
SUPELCOWAX 10 25300-U 15 0.53 1.00 DB-WAXetr
HP-INNOWax
125-7312
19095N-121
 
SUPELCOWAX 10 25301-U 30 0.53 1.00 DB-WAXetr
HP-INNOWax
125-7332
19095N-121
 
SUPELCOWAX 10 25375-U 30 0.53 2.00 DB-WAXetr 125-7334  
SUPEL-Q PLOT 24242 30 0.32 NA HP-PLOT Q 19091P-Q04  
SUPEL-Q PLOT 25462 30 0.53 NA HP-PLOT Q 19095P-Q04  
VOCOL 24127-U 60 0.32 1.80 DB-VRX
HP-VOC
123-1564
19091R-316
Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 24129-U 10 0.20 1.20 DB-VRX 121-1524 Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 24205-U 30 0.25 1.50 DB-VRX 122-1534 Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 25320-U 30 0.53 3.00 DB-VRX 124-1534 Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 24154 60 0.25 1.50 DB-VRX 122-1564 Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 24157 60 0.32 3.00 DB-VRX 123-1564 Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 25381 60 0.53 3.00 DB-VRX 124-1574 Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.
VOCOL 25358 105 0.53 3.00 DB-VRX
HP-VOC
124-1574
19095R-420
Different polymer but the DB-VRX is excellent for VOCs and is widely accepted and established.