<%flg="B"%>
 

GC Column Cross Reference

Upgrade to an Agilent J&W GC Column

If you are using a Chrompack/Varian GC column and would like to upgrade to an Agilent J&W column, this GC column cross-reference guide will make your conversion easy. Each section of this guide lists, by phase selection, the suggested Agilent J&W upgrade from Chrompack/Varian's columns. 

This is not, however, a complete listing, but represents only the most frequently used columns. If you do not find the column you are currently using and would like to upgrade to an Agilent J&W column, call our Technical Support staff, free of charge, for assistance at 800-227-9770 or outside of North America call 916-985-7888 or e:mail us

Tip: To find the Agilent upgrade  for the Chrompack/Varian phase or part number you are currently using, select the "Find" function from your internet browser "Edit" menu.

Varian Description Varian P/N Length (m) I.D. (mm) Film (Ám) Agilent J&W Phase Agilent J&W P/N Notes
CP-Sil 5 CB CP7125 10 0.53 0.50 DB-PS1 145-1017 Slightly different dimensions.
CP-Sil 5 CB CP7135 25 0.53 0.50 DB-PS1 145-1037 Slightly different dimensions.
CP-Sil 5 CB CP7300 5 0.10 0.12 DB-1 127-100A
CP-Sil 5 CB CP7441 25 0.25 0.25 DB-1 122-1022
CP-Sil 5 CB CP7442 25 0.32 0.25 DB-1 123-1022
CP-Sil 5 CB CP7443 50 0.25 0.25 DB-1 122-1052
CP-Sil 5 CB CP7444 50 0.32 0.25 DB-1 123-1052
CP-Sil 5 CB CP7625 10 0.53 1.00 DB-1 125-101J Slightly different dimensions.
CP-Sil 5 CB CP7635 25 0.53 1.00 DB-1 125-102J
CP-Sil 5 CB CP7645 10 0.53 5.00 DB-1 125-10H5
CP-Sil 5 CB CP7670 25 0.25 1.20 DB-1 122-1033
CP-Sil 5 CB CP7675 25 0.53 5.00 DB-1 125-1025
CP-Sil 5 CB CP7680 25 0.32 5.00 DB-1 123-1035
CP-Sil 5 CB CP7685 50 0.53 5.00 DB-1 125-1055
CP-Sil 5 CB CP7700 10 0.25 0.12 HP-1 19091Z-331 Slightly different dimensions.
CP-Sil 5 CB CP7740 25 0.32 0.12 DB-1 123-1027
CP-Sil 5 CB CP7758 10 0.32 1.20 DB-1 123-1013 Slightly different dimensions.
CP-Sil 5 CB CP7760 25 0.32 1.20 DB-1 123-1033
CP-Sil 5 CB CP7770 50 0.32 1.20 DB-1 123-105C
CP-Sil 5 CB CP8430 25 0.32 0.52 DB-1
HP-1
123-1026
19091Z-112
CP-Sil 5 CB CP8510 15 0.25 0.25 DB-1
HP-1
122-1012
19091Z-431
CP-Sil 5 CB CP8520 15 0.25 1.00 DB-1
HP-1
122-1013
19091Z-231
CP-Sil 5 CB CP8530 15 0.32 0.25 DB-1
HP-1
123-1012
19091Z-411
CP-Sil 5 CB CP8540 15 0.32 1.00 DB-1
HP-1
123-1013
19091Z-211
CP-Sil 5 CB CP8550 15 0.32 3.00 DB-1 123-1014
CP-Sil 5 CB CP8560 15 0.32 5.00 DB-1 123-1015
CP-Sil 5 CB CP8673 15 0.53 0.15 DB-1 125-1011
CP-Sil 5 CB CP8675 15 0.53 3.00 DB-1
HP-1
125-1014
19095Z-421
CP-Sil 5 CB CP8677 30 0.53 3.00 DB-1
HP-1
125-1034
19095Z-423
CP-Sil 5 CB CP8685 60 0.53 5.00 DB-1
HP-1
125-1065
19095Z-626
CP-Sil 5 CB CP8687 30 0.32 3.00 DB-1
HP-1
123-1034
19091Z-513
CP-Sil 5 CB CP8689 60 0.32 3.00 DB-1 123-1064
CP-Sil 5 CB CP8740 30 0.32 0.10 DB-1
HP-1
123-1031
19091Z-313
CP-Sil 5 CB CP8743 60 0.25 0.25 DB-1
HP-1
122-1062
19091Z-436
CP-Sil 5 CB CP8780 60 0.25 1.00 DB-1
HP-1
122-1063
19091Z-236
CP-Sil 5 CB CP8799 60 0.53 1.50 DB-1 125-1062
CP-Sil 5 CB CP8870 60 0.32 1.00 DB-1
HP-1
123-1063
19091Z-216
CP-Sil 5 CB CP8760 30 0.32 1.00 DB-1
HP-1
123-1033
19091Z-213
CP-Sil 5 CB CP8710 30 0.25 0.10 DB-1
HP-1
122-1031
19091Z-333
CP-Sil 5 CB CP8690 60 0.32 5.00 DB-1
HP-1
123-1065
19091Z-716
CP-Sil 5 CB CP8688 30 0.32 5.00 DB-1
HP-1
123-1035
19091Z-713
CP-Sil 5 CB CP8775 30 0.53 5.00 DB-1
HP-1
125-1035
19095Z-623
CP-Sil 5 CB CP8770 30 0.25 1.00 DB-1
HP-1
122-1033
19091Z-233
CP-Sil 5 CB CP8676 15 0.53 5.00 DB-1
HP-1
125-1015
19095Z-621
CP-Sil 5 CB CP8735 30 0.53 1.50 DB-1
HP-1
125-1032
19095Z-323
CP-Sil 5 CB CP8674 15 0.53 1.50 DB-1
HP-1
125-1012
19095Z-321
CP-Sil 5 CB CP8744 60 0.32 0.25 DB-1
HP-1
123-1062
19091Z-416
CP-Sil 5 CB CP8742 30 0.32 0.25 DB-1
HP-1
123-1032
19091Z-413
CP-Sil 5 CB CP8741 30 0.25 0.25 DB-1
HP-1
122-1032
19091Z-433
CP-Sil 5 CB CP7310 10 0.10 0.12 DB-1 127-101A
CP-Sil 5 CB-LowBleed/MS CP7842 25 0.25 0.25 DB-1 122-1022
CP-Sil 5 CB-LowBleed/MS CP7843 50 0.25 0.25 DB-1 122-1052
CP-Sil 5 CB-LowBleed/MS CP7846 25 0.32 0.12 DB-1 123-1027
CP-Sil 5 CB-LowBleed/MS CP7848 25 0.32 0.25 DB-1 123-1022
CP-Sil 5 CB-LowBleed/MS CP7849 50 0.32 0.25 DB-1 123-1052
CP-Sil 5 CB-LowBleed/MS CP7853 50 0.32 1.20 DB-1 123-105C
CP-Sil 5 CB-LowBleed/MS CP7854 25 0.32 0.52 DB-1
HP-1ms
123-1026
19091S-612
CP-Sil 5 CB-LowBleed/MS CP7866 60 0.32 1.00 DB-1
HP-1
123-1063
19091Z-216
CP-Sil 5 CB-LowBleed/MS CP7865 30 0.32 1.00 DB-1
HP-1ms
123-1033
19091S-713
CP-Sil 5 CB-LowBleed/MS CP7864 60 0.32 0.25 DB-1
HP-1ms
123-1062
19091S-916
CP-Sil 5 CB-LowBleed/MS CP7863 30 0.32 0.25 DB-1ms
HP-1ms
123-1032
19091S-913
CP-Sil 5 CB-LowBleed/MS CP7862 30 0.25 1.00 DB-1
HP-1ms
122-1033
19091S-733
CP-Sil 5 CB-LowBleed/MS CP7861 60 0.25 0.25 DB-1ms
HP-1ms
122-1062
19091S-936
CP-Sil 5 CB-LowBleed/MS CP7860 30 0.25 0.25 DB-1ms
HP-1ms
122-1032
19091S-933
CP-Sil 5 CB-LowBleed/MS CP7857 60 0.25 1.00 DB-1
HP-1
122-1063
19091Z-236
CP-Sil 5 CB-LowBleed/MS CP7856 60 0.32 0.10 DB-1 123-1061
CP-Sil 5 CB-LowBleed/MS CP7855 30 0.32 0.10 DB-1ms
HP-1ms
123-1031
19091S-813
CP-Sil 5 CB-LowBleed/MS CP7818 60 0.25 0.10 DB-1 122-1061
CP-Sil 5 CB-LowBleed/MS CP7817 30 0.25 0.10 DB-1ms
HP-1ms
122-1031
19091S-833
CP-Sil 5 CB-LowBleed/MS CP7815 15 0.32 0.25 DB-1ms
HP-1ms
123-1012
19091S-911
CP-Sil 5 CB-LowBleed/MS CP7814 15 0.32 0.10 DB-1 123-1011
CP-Sil 5 CB-LowBleed/MS CP7812 15 0.25 1.00 DB-1
HP-1
122-1013
19091Z-231
CP-Sil 5 CB-LowBleed/MS CP7811 15 0.25 0.25 DB-1ms
HP-1ms
122-1012
19091S-931
CP-Sil 5 CB-LowBleed/MS CP7810 15 0.25 0.10 DB-1
HP-1
122-1011
19091Z-331
CP-Sil 8 CB CP7451 25 0.25 0.25 DB-5 122-5022
CP-Sil 8 CB CP7452 25 0.32 0.25 DB-5 123-5022
CP-Sil 8 CB CP7454 50 0.32 0.25 DB-5 123-5052
CP-Sil 8 CB CP7621 10 0.53 2.00 DB-5 125-50H3
CP-Sil 8 CB CP7626 10 0.53 1.00 DB-5 125-501J
CP-Sil 8 CB CP7631 25 0.53 2.00 DB-5 125-5032
CP-Sil 8 CB CP7636 25 0.53 1.00 DB-5 125-503J Slightly different dimensions.
CP-Sil 8 CB CP7646 10 0.53 5.00 DB-5 125-50H5
CP-Sil 8 CB CP7656 25 0.53 5.00 DB-5 125-5025
CP-Sil 8 CB CP7671 25 0.25 1.20 DB-5 122-502C
CP-Sil 8 CB CP7696 50 0.53 1.00 DB-5 125-505J
CP-Sil 8 CB CP7721 50 0.25 0.12 DB-5 122-5061
CP-Sil 8 CB CP7731 10 0.32 0.12 DB-5 123-5011
CP-Sil 8 CB CP7741 25 0.32 0.12 DB-5
HP-5
123-5031
19091J-012
CP-Sil 8 CB CP7751 50 0.32 0.12 DB-5
HP-5
123-505D
19091J-015
CP-Sil 8 CB CP7759 25 0.25 0.40 DB-5 122-503E
CP-Sil 8 CB CP7761 25 0.32 1.20 DB-5 123-5033
CP-Sil 8 CB CP7771 50 0.32 1.20 DB-5 123-5053
CP-Sil 8 CB CP7779 25 0.32 0.40 DB-5 123-503E
CP-Sil 8 CB CP7885 10 0.15 1.20 DB-5 12A-5015
CP-Sil 8 CB CP8431 25 0.32 0.52 DB-5 12A-5015
CP-Sil 8 CB CP8511 15 0.25 0.25 DB-5
HP-5
122-5012
19091J-431
CP-Sil 8 CB CP8521 15 0.25 1.00 DB-5
HP-5
122-5013
19091J-231
CP-Sil 8 CB CP8531 15 0.32 0.25 DB-5
HP-5
123-5012
19091J-411
CP-Sil 8 CB CP8541 15 0.32 1.00 DB-5
HP-5
123-5013
19091J-211
CP-Sil 8 CB CP8716 30 0.53 0.50 DB-5 125-5037
CP-Sil 8 CB CP8753 60 0.25 0.25 DB-5
HP-5
122-5062
19091J-436
CP-Sil 8 CB CP8763 30 0.53 1.50 DB-5
HP-5
125-5032
19095J-323
CP-Sil 8 CB C8781 60 0.25 1.00 DB-5
HP-5
122-5063
19091J-236
CP-Sil 8 CB CP8791 30 0.32 0.12 HP-5 19091J-313 Slightly different dimensions.
CP-Sil 8 CB CP8796 60 0.53 1.50 DB-5 125-5062
CP-Sil 8 CB CP8754 60 0.32 0.25 DB-5
HP-5
123-5062
19091J-416
CP-Sil 8 CB CP8752 30 0.32 0.25 DB-5
HP-5
123-5032
19091J-413
CP-Sil 8 CB CP8871 60 0.32 1.00 DB-5
HP-5
123-5063
19091J-216
CP-Sil 8 CB CP7769 50 0.25 0.40 DB-5 122-506E
CP-Sil 8 CB CP8761 30 0.32 1.00 DB-5
HP-5
123-5033
19091J-213
CP-Sil 8 CB CP8751 30 0.25 0.25 DB-5
HP-5
122-5032
19091J-433
CP-Sil 8 CB CP7711 25 0.25 0.12 DB-5 122-5031
CP-Sil 8 CB CP8771 30 0.25 1.00 DB-5
HP-5
122-5033
19091J-233
CP-Sil 8 CB CP8756 30 0.53 5.00 DB-5
HP-5
125-5035
19095J-623
CP-Sil 8 CB CP8678 15 0.53 1.50 DB-5
HP-5
125-5012
19095J-321
CP-Sil 8 CB CP7453 50 0.25 0.25 DB-5 122-5052
CP-Sil 8 CB CP7315 10 0.10 0.12 DB-5 127-5012
CP-Sil 8 CB for Amines CP7596 50 0.32 1.00 DB-5 123-5053
CP-Sil 8 CB for Amines CP7597 50 0.53 1.00 DB-5 125-505J
CP-Sil 8 CB for Amines CP7598 50 0.25 0.25 DB-5 122-5052
CP-Sil 8 CB for PCB CP7482 50 0.25 0.25 DB-5 122-5052
CP-Sil 8 CB-LowBleed/MS CP5840 25 0.25 0.12 DB-5ms 122-5531
CP-Sil 8 CB-LowBleed/MS CP5842 25 0.25 0.25 DB-5ms 122-5522
CP-Sil 8 CB-LowBleed/MS CP5843 50 0.25 0.25 DB-5ms 122-5552
CP-Sil 8 CB-LowBleed/MS CP5844 25 0.25 0.40 DB-5ms 122-552A
CP-Sil 8 CB-LowBleed/MS CP5846 25 0.32 0.12 DB-5ms 123-5531
CP-Sil 8 CB-LowBleed/MS CP5848 25 0.32 0.25 DB-5ms 123-5532
CP-Sil 8 CB-LowBleed/MS CP5849 50 0.32 0.25 DB-5ms 123-5552
CP-Sil 8 CB-LowBleed/MS CP5850 25 0.32 0.40 DB-5ms 123-5536
CP-Sil 8 CB-LowBleed/MS CP5852 25 0.32 1.20 DB-5ms 123-5533
CP-Sil 8 CB-LowBleed/MS CP5853 50 0.32 1.20 DB-5ms 123-5553
CP-Sil 8 CB-LowBleed/MS CP5869 15 0.25 1.00 DB-5ms
HP-5ms
122-5513
19091S-231
CP-Sil 8 CB-LowBleed/MS CP5870 30 0.25 0.10 DB-5ms
HP-5ms
122-5531
19091S-333
CP-Sil 8 CB-LowBleed/MS CP5871 30 0.25 0.50 DB-5ms
HP-5ms
122-5536
19091S-133
CP-Sil 8 CB-LowBleed/MS CP5874 15 0.32 0.25 DB-5ms
HP-5ms
123-5512
19091S-411
CP-Sil 8 CB-LowBleed/MS CP5876 25 0.32 0.52 DB-5ms
HP-5ms
123-5526
19091S-112
CP-Sil 8 CB-LowBleed/MS CP5880 30 0.32 0.50 DB-5ms
HP-5ms
123-5536
19091S-113
CP-Sil 8 CB-LowBleed/MS CP5877 30 0.32 0.10 DB-5ms
HP-5ms
123-5531
19091S-313
CP-Sil 8 CB-LowBleed/MS CP5875 15 0.32 1.00 DB-5ms
HP-5ms
123-5513
19091S-211
CP-Sil 8 CB-LowBleed/MS CP5873 15 0.32 0.10 DB-5ms
HP-5ms
123-5511
19091S-311
CP-Sil 8 CB-LowBleed/MS CP5872 60 0.25 0.10 DB-5ms
HP-5ms
122-5561
19091S-336
CP-Sil 8 CB-LowBleed/MS CP5870 30 0.25 0.10 DB-5ms
HP-5ms
122-5531
19091S-333
CP-Sil 8 CB-LowBleed/MS CP5868 15 0.25 0.25 DB-5ms
HP-5ms
122-5512
19091S-431
CP-Sil 8 CB-LowBleed/MS CP5867 15 0.25 0.10 DB-5ms
HP-5ms
122-5511
19091S-331
CP-Sil 8 CB-LowBleed/MS CP5866 60 0.32 1.00 DB-5ms 123-5563
CP-Sil 8 CB-LowBleed/MS CP5865 30 0.32 1.00 DB-5ms
HP-5ms
123-5533
19091S-213
CP-Sil 8 CB-LowBleed/MS CP5864 60 0.32 0.25 DB-5ms
HP-5ms
123-5562
19091S-416
CP-Sil 8 CB-LowBleed/MS CP5863 30 0.32 0.25 DB-5ms
HP-5ms
123-5532
19091S-413
CP-Sil 8 CB-LowBleed/MS CP5862 30 0.25 1.00 DB-5ms
HP-5ms
122-5533
19091S-233
CP-Sil 8 CB-LowBleed/MS CP5861 60 0.25 0.25 DB-5ms
HP-5ms
122-5562
19091S-436
CP-Sil 8 CB-LowBleed/MS CP5860 30 0.25 0.25 DB-5ms
HP-5ms
122-5532
19091S-433
CP-Sil PONA CB CP7530 100 0.25 0.50 DB-Petro100
HP-1
122-10A6
19091Z-530
CP-Sil PONA CB for ASTM D5134-9 CP7531 50 0.21 0.50 DB-Petro50
HP-PONA
128-1056
19091S-001
Slightly different dimensions.
CP-Sil88 for Dioxins CP7498 50 0.25 0.10 DB-Dioxin 122-2462 Different phase, optimal solution for application
CP-Sil88 for Dioxins CP7499 60 0.32 0.13 DB-Dioxin 123-2461 Different phase, optimal solution for application
CP-Sil88 for Dioxins CP7588 50 0.25 0.20 DB-Dioxin 122-2462 Different phase, optimal solution for application
CP-SilicaPLOT CP8566 15 0.32 4.00 GS-GasPro 113-4312
CP-SilicaPLOT CP8567 30 0.32 4.00 GS-GasPro 123-4332
CP-SilicaPLOT CP8568 60 0.32 4.00 GS-GasPro 123-4362
CP-SimDist CP7522 5 0.53 0.17 DB-HTSimDis
HP-PONA
145-1001
19095Z-221
Slightly different dimensions
CP-SimDist CP7532 5 0.53 0.17 DB-HTSimDis 145-1001 Slightly different dimensions
CP-Sil 19 CB CP8502 15 0.25 0.15 DB-1701 122-0711
CP-Sil 19 CB CP8512 15 0.25 0.25 DB-1701 122-0712
CP-Sil 19 CB CP8542 15 0.32 0.25 DB-1701 123-0712
CP-Sil 19 CB CP8552 15 0.32 1.00 DB-1701 123-0713
CP-Sil 19 CB CP8562 30 0.25 1.00 DB-1701 122-0733
CP-Sil 19 CB CP8572 60 0.25 1.00 DB-1701 122-0763
CP-Sil 19 CB CP8592 60 0.25 0.15 DB-1701 122-0761
CP-Sil 19 CB CP8661 30 0.32 0.15 DB-1701 123-0731
CP-Sil 19 CB CP8722 60 0.25 0.25 DB-1701 122-0762
CP-Sil 19 CB CP8737 30 0.53 1.00 DB-1701 125-0732
CP-Sil 19 CB CP8842 30 0.32 0.25 DB-1701 123-0732
CP-Sil 19 CB CP8852 60 0.32 0.25 DB-1701 123-0762
CP-Sil 19 CB for pesticides CP7406 30 0.25 0.25 DB-1701P 122-7732
CP-Sil 19 CB for pesticides CP7408 30 0.32 0.25 DB-1701P 123-7732
CP-Sil 19 CB for pesticides CP7409 30 0.53 1.00 DB-1701P 125-7732
CP-Sil 19 CB CP8762 30 0.32 1.00 DB-1701 123-0733
CP-Sil 19 CB CP8772 60 0.32 1.00 DB-1701 123-0763
CP-Sil 19 CB CP8712 30 0.25 0.25 DB-1701 122-0732
CP-Sil 19 CB CP8663 15 0.53 0.50 DB-1701 125-0717
CP-Sil 24 CB CP7822 60 0.25 0.25 DB-17
HP-50+
122-1762
19091L-436
CP-Sil 24 CB CP7832 60 0.32 0.25 DB-17
HP-50+
123-1762
19091L-416
CP-Sil 24 CB CP7835 60 0.32 0.50 DB-17
HP-50+
123-1763
19091L-116
CP-Sil 24 CB CP7872 60 0.53 1.00 DB-17 125-1762
CP-Sil 24 CB CP7871 30 0.53 1.00 DB-17
HP-50+
125-1732
19095L-023
CP-Sil 24 CB CP7870 15 0.53 1.00 DB-17
HP-50+
125-1712
19095L-021
CP-Sil 24 CB CP7834 30 0.32 0.50 DB-17
HP-50+
123-1733
19091L-113
CP-Sil 24 CB CP7833 15 0.32 0.50 DB-17
HP-50+
123-1713
19091L-111
CP-Sil 24 CB CP7831 30 0.32 0.25 DB-17
HP-50+
123-1732
19091L-413
CP-Sil 24 CB CP7830 15 0.32 0.25 DB-17
HP-50+
123-1712
19091L-411
CP-Sil 24 CB CP7824 30 0.25 0.50 DB-17
HP-50+
122-1733
19091L-133
CP-Sil 24 CB CP7821 30 0.25 0.25 DB-17
HP-50+
122-1732
19091L-433
CP-Sil 24 CB CP7820 15 0.25 0.25 DB-17
HP-50+
122-1712
19091L-431
CP-Sil 24 CB-Low Bleed/MS CP5813 15 0.25 0.15 DB-17ms 122-4711
CP-Sil 24 CB-Low Bleed/MS CP5814 30 0.25 0.15 DB-17ms 122-4731
CP-Sil 24 CB-Low Bleed/MS CP5816 15 0.25 0.25 DB-17ms 122-4712
CP-Sil 24 CB-Low Bleed/MS CP5817 30 0.25 0.25 DB-17ms 122-4732
CP-Sil 24 CB-Low Bleed/MS CP5822 15 0.32 0.15 DB-17ms 123-4711
CP-Sil 24 CB-Low Bleed/MS CP5823 30 0.32 0.15 DB-17ms 123-4731
CP-Sil 24 CB-Low Bleed/MS CP5825 15 0.32 0.25 DB-17ms 123-4712
CP-Sil 24 CB-Low Bleed/MS CP5826 30 0.32 0.25 DB-17ms 123-4732
CP-Sil 43 CB CP7705 10 0.25 0.20 DB-225 122-2212 Slightly different dimensions.
CP-Sil 43 CB CP7715 25 0.25 0.20 DB-225 122-2232 Slightly different dimensions.
CP-Sil 43 CB CP7735 10 0.32 0.20 DB-225 123-2212 Slightly different dimensions.
CP-Sil 43 CB CP7745 25 0.32 0.20 DB-225 123-2232 Slightly different dimensions.
CP-WAX 52 CB CP7148 10 0.53 1.00 DB-WAX 145-7012 Slightly different dimensions.
CP-WAX 52 CB CP7158 25 0.53 1.00 DB-WAX 145-7032 Slightly different dimensions.
CP-WAX 52 CB CP8503 15 0.25 0.15 DB-WAX 122-7011
CP-WAX 52 CB CP8513 15 0.25 0.25 DB-WAX
HP-INNOWax
122-7012
19091N-131
CP-WAX 52 CB CP8523 15 0.25 0.50 DB-WAX
HP-INNOWax
122-7013
19091N-231
CP-WAX 52 CB CP8533 15 0.32 0.15 DB-WAX 123-7011
CP-WAX 52 CB CP8543 15 0.32 0.25 DB-WAX
HP-INNOWax
123-7012
19091N-111
CP-WAX 52 CB CP8553 15 0.32 0.50 DB-WAX
HP-INNOWax
123-7013
19091N-211
CP-WAX 52 CB CP8718 15 0.53 1.00 DB-WAX
HP-INNOWax
125-7012
19095N-121
CP-WAX 52 CB CP8745 30 0.25 0.15 DB-WAX
HP-INNOWax
122-7031
19091N-033
CP-WAX 52 CB CP8746 30 0.25 0.50 DB-WAX
HP-INNOWax
122-7033
19091N-233
CP-WAX 52 CB CP8747 60 0.25 0.15 DB-WAX
HP-INNOWax
122-7061
19091N-036
CP-WAX 52 CB CP8748 60 0.25 0.50 DB-WAX
HP-INNOWax
122-7063
19091N-236
CP-WAX 52 CB CP8757 30 0.32 0.15 DB-WAX
HP-INNOWax
123-7031
19091N-013
CP-WAX 52 CB CP8758 60 0.32 0.15 HP-INNOWax 19091N-016
CP-WAX 52 CB CP8763 30 0.32 0.50 DB-WAX
HP-INNOWax
123-7033
19091N-213
CP-WAX 52 CB CP8773 60 0.32 0.50 DB-WAX
HP-INNOWax
123-7063
19091N-216
CP-WAX 52 CB CP8798 60 0.53 1.00 DB-WAX
HP-INNOWax
125-7062
19095N-126
CP-WAX 52 CB CP8853 60 0.32 0.25 DB-WAX
HP-INNOWax
123-7062
19091N-116
CP-WAX 52 CB CP8843 30 0.32 0.25 DB-WAX
HP-INNOWax
123-7032
19091N-113
CP-WAX 52 CB CP8723 60 0.25 0.25 DB-WAX
HP-INNOWax
122-7062
19091N-136
CP-WAX 52 CB CP8713 30 0.25 0.25 DB-WAX
HP-INNOWax
122-7032
19091N-133
CP-WAX 52 CB CP8738 30 0.53 1.00 DB-WAX
HP-INNOWax
125-7032
19095N-123
CP-WAX 52 CB CP7335 10 0.10 0.20 DB-WAX 127-7013
CP-Wax 57 CB CP8120 60 0.25 0.40 DB-WAX 122-7063 Slightly different dimensions and polymer
CP-Wax 57 CB CP97638 25 0.53 1.00 DB-WAX 125-7032 Slightly different dimensions and polymer
CP-Wax 57 CB CP97713 25 0.25 0.20 DB-WAX 122-7032 Slightly different dimensions and polymer
CP-Wax 57 CB CP97723 50 0.25 0.20 DB-WAX 122-7061 Slightly different dimensions and polymer
CP-Wax 57 CB CP97753 50 0.32 0.20 DB-WAX 123-7062 Slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7614 25 0.53 1.00 DB-FFAP 125-3232 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7624 50 0.53 1.00 DB-FFAP 125-3262 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7654 25 0.53 2.00 DB-FFAP 125-3233 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7717 25 0.25 0.20 DB-FFAP 122-3232 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7727 50 0.25 0.20 DB-FFAP 122-3262 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7747 25 0.32 0.20 DB-FFAP 123-3223 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7757 50 0.32 0.20 DB-FFAP 123-3253 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7767 25 0.32 1.20 DB-FFAP 123-3234 slightly different dimensions and polymer
CP-Wax 58 (FFAP) CB CP7777 50 0.32 1.20 DB-FFAP 123-3264 slightly different dimensions and polymer
CP-Select 624 CB CP7412 30 0.25 1.40 DB-624 122-1334
CP-Select 624 CB CP7413 60 0.25 1.40 DB-624 123-1364
CP-Select 624 CB CP7414 30 0.32 1.80 DB-624 123-1334
CP-Select 624 CB CP7415 60 0.32 1.80 DB-624 123-1364
CP-Select 624 CB CP7416 30 0.53 3.00 DB-624 125-1334
CP-Select 624 CB CP7417 75 0.53 3.00 DB-624 125-1374
CP-Select CB for MTBE CP7528 50 0.25 0.25 DB-MTBE 124-0034 Different phase, optimal solution for application
CP-Sil 13 CB CP7609 10 0.53 1.00 DB-XLB 125-1212 Slightly different dimensions and polymer
CP-Sil 13 CB CP7619 25 0.53 1.00 DB-XLB 125-1232 Slightly different dimensions and polymer
CP-Sil 13 CB CP7639 10 0.53 2.00 DB-XLB 125-1212 Slightly different dimensions and polymer
CP-Sil 13 CB CP7649 25 0.53 2.00 DB-XLB 125-1232 Slightly different dimensions and polymer
CP-Sil 13 CB CP7906 25 0.25 0.20 DB-XLB 122-1232 Slightly different dimensions and polymer
CP-Sil 13 CB CP7907 50 0.25 0.20 DB-XLB 122-1262 Slightly different dimensions and polymer
CP-Sil 13 CB CP7916 25 0.25 0.40 DB-XLB 122-1236 Slightly different dimensions and polymer
CP-Sil 13 CB CP7926 25 0.32 0.20 DB-XLB 123-1232 Slightly different dimensions and polymer
CP-Sil 13 CB CP7927 50 0.32 0.20 DB-XLB 123-1262 Slightly different dimensions and polymer
CP-Sil 13 CB CP7936 25 0.32 0.40 DB-XLB 123-1236 Slightly different dimensions and polymer
CP-Sil 13 CB CP7946 25 0.32 1.20 DB-XLB 123-1233 Slightly different dimensions and polymer
CP-Sil 13 CB CP7977 25 0.25 1.20 DB-XLB 122-1233 Slightly different dimensions and polymer
CP-Sil 13 CB for halocarbons CP7508 25 0.53 2.00 DB-XLB 125-1232
CP-1301 CP8603 15 0.25 1.00 DB-1301 122-1313
CP-1301 CP8604 30 0.25 1.00 DB-1301 122-1333
CP-1301 CP8605 60 0.25 1.00 DB-1301 122-1363
CP-1301 CP8609 15 0.32 1.00 DB-1301 123-1313
CP-1301 CP8610 30 0.32 1.00 DB-1301 123-1333
CP-1301 CP8611 60 0.32 1.00 DB-1301 123-1363
CP-1301 CP8613 30 0.53 1.00 DB-1301 125-1332
CP-1301 CP8612 15 0.53 1.00 DB-1301 125-1312
CP-1301 CP8608 60 0.32 0.25 DB-1301 123-1362
CP-1301 CP8607 30 0.32 0.25 DB-1301 123-1332
CP-1301 CP8606 15 0.32 0.25 DB-1301 123-1312
CP-1301 CP8602 60 0.25 0.25 DB-1301 122-1362
CP-1301 CP8601 30 0.25 0.25 DB-1301 122-1332
CP-1301 CP8600 15 0.25 0.25 DB-1301 122-1312
CP-AI2O3/KCI CP7515 50 0.32 5.00 HP-PLOT AI2O3 19091P-M15
CP-Al2O3/KCl CP7518  -  - - HP-PLOT AI2O3 19095P-M25
CP-Al2O3/KCl CP7517  - - - HP-PLOT AI2O3 19095P-M23 Slightly different dimensions.
CP-AI2O3 PLOT/NaSO4 CP7565 50 0.32 5.00 HP-PLOT AI2O3 19091P-S15
CP-AI2O3 PLOT/NaSO4 CP7567 - - - HP-PLOT AI2O3 19095P-S23 Slightly different dimensions.
CP-AI2O3 PLOT/NaSO4 CP7568 - - - HP-PLOT AI2O3 19095P-S25
CP-AI2O3 PLOT/NaSO4 CP7586 - - - HP-PLOT AI2O3" 19091P-S33 Slightly different dimensions.
CP-CarboBOND CP7374 25 0.53 10.00 GS-CarbonPLOT 115-3133 Slightly different dimensions.
CP-CarboPLOT P7 CP7513 10 0.53 25.00 GS-CarbonPLOT 115-3113 Slightly different dimensions.
CP-CarboPLOT P7 CP7514 25 0.53 25.00 GS-CarbonPLOT 115-3133 Slightly different dimensions.
CP-Chiralsil-DEX CB CP7502 25 0.25 0.25 CycloSil-B 112-6632 Slightly different dimensions.
CP-Chiralsil-DEX CB CP7503 25 0.32 0.25 CycloSil-B 113-6632 Slightly different dimensions.
CP-FFAP CB CP7486 25 0.53 1.00 DB-FFAP
HP-FFAP
125-3232
19095F-123
Slightly different dimensions.
CP-Molsieve 5A CP7534 30 0.32 10.00 HP-PLOT Mole Sieve 19091P-MS4
CP-Molsieve 5A CP7535 10 0.32 30.00 HP-PLOT Mole Sieve 19091P-MS7
CP-Molsieve 5A CP7536 25 0.32 30.00 HP-PLOT Mole Sieve 19091P-MS8 Slightly different dimensions.
CP-Molsieve 5A CP7537 10 0.53 50.00 HP-PLOT Mole Sieve 19095P-MS9 Slightly different dimensions.
CP-Molesieve 5A CP7538 25 0.53 50.00 HP-PLOT Mole Sieve 19095P-MS0 Slightly different dimensions.
CP-PoraBOND Q CP7350 10 0.32 5.00 HP-PLOT Q 19091P-QO3 Slightly different dimensions.
CP-PoraBOND Q CP7351 25 0.32 5.00 HP-PLOT Q 19091P-QO4 Slightly different dimensions.
CP-PoraBOND Q CP7353 10 0.53 10.00 HP-PLOT Q 19095P-QO3 Slightly different dimensions.
CP-PoraBOND Q CP7354 25 0.53 10.00 HP-PLOT Q 19095P-QO4 Slightly different dimensions.
CP-PoraPLOT Q CP7550 10 0.32 10.00 HP-PLOT Q 19091P-QO3 Slightly different dimensions.
CP-PoraPLOT Q CP7551 25 0.32 10.00 HP-PLOT Q 19091P-QO4 Slightly different dimensions.
CP-PoraPLOT Q CP7553 10 0.53 20.00 HP-PLOT Q 19095P-QO3 Slightly different dimensions.
CP-PoraPLOT Q CP7554 25 0.53 20.00 HP-PLOT Q 19095P-QO4 Slightly different dimensions.
CP-PoraPLOT U CP7580 10 0.32 10.00 HP-PLOT U 19091P-UO3 Slightly different dimensions.
CP-PoraPLOT U CP7581 25 0.32 10.00 HP-PLOT U 19091P-UO4 Slightly different dimensions.
CP-PoraPLOT U CP7583 10 0.53 20.00 HP-PLOT U 19095P-UO3 Slightly different dimensions.
CP-PoraPLOT U CP7584 25 0.53 20.00 HP-PLOT U 19095P-UO4 Slightly different dimensions.