- Superior nebulization delivers more ions to the mass spectrometer
- High drying capacity improves performance
- Orthogonal nebulization simplified operation and reduces maintenance
- Dual nebulizers maximize mass accuracy
- Multiple ionization techniques to serve more application
- more...
| |
|
|
|
|
 |
 |
| Multimode source |
 |
 |
- The only ion source capable of simultaneously generating ions by electrospray (ESI) and atmospheric pressure chemical ionization (APCI)
- Identifies very diverse compounds in a single run with spectrum-to-spectrum polarity switching
- Operates in ESI-only or APCI-only mode
- more...
|
|
Electrospray (ESI) |
 |
 |
- Multiple charging and relatively low operating temperatures allow for analysis of biological macro-molecules such as proteins and peptides, as well as for smaller, more polar molecules.
- Concentration-sensitive technique: more concentrated samples improve sensitivity
- Available for Standard-flow-rate electrospray, Capillary electrospray, and nanoelectrospray
- more...
|
| Atmospheric pressure chemical ionization (APCI) |
 |
 |
- Popular complement to electrospray, generates primarily singly charged ions and operates at higher temperatures for wide range of less polar and non-polar molecules
- Mass-flow sensitive technique: more sample molecules improve performance
- Works better with larger columns and higher LC flow rates
|
| HPLC-Chip nanoelectrospray |
 |
 |
- Reusable HPLC-Chips seamlessly integrate the sample enrichment and separation nanocolumns, tubing, connections, and spray needle of a traditional nanoelectrospray LC/MS system into a biocompatible polymer chip
- Narrower, better-defined peaks due to elimination of post-column dead volumes
- Concentration-dependent technique: HPLC-Chip can dramatically improve sensitivity
- Sealed, robotic interface for fully automated handling
|
| Atmospheric pressure photoionization (APPI) |
 |
 |
- For analysis of compounds that ionize poorly by ESI and APCI
- Syagen Technology ensures that RF-resonated krypton lamp emits photons at energy levels high enough to ionize many classes of compounds with minimal ionization of air and common HPLC solvents
- Easily determines molecular weights due to minimal fragmentation
- more...
|
| Atmospheric-pressure MALDI (AP/MALDI) |
 |
 |
- Provides fast, easy and ultrasensitive analysis of 2D gel-spot digests and samples that do not need online separation with integrated pulsed dynamic focusing
- Excellent solution for high throughput screening, expression profiling studies, and protein identification and confirmation using peptide mass fingerprinting
- Available for purchase from MassTech
- Application Notes
| |
|
|
|
 |
Application of Ionization Techniques |
|
 |
 | |
 |
 |
- No ionization technique is suitable for all applications, but Agilent offers you a wide range of choices
- View application table
| |
|
|
|

 |
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
|
|
 |
|
|