Agilent Technologies LSCA - Our measure is your success
clear
white
clear
white
clear

Ordering Details - 6100 Series Quadrupole LC/MS Systems 

white
clear clear clear clear clear

grey1
Literature Library
Technical Support
Education & Events

grey1
To place an order or get more detailed ordering information including prices and availability, contact your local Agilent sales office or distributor (in the U.S. and Canada, call 1-800-227-9770; Option 2,1) or Request a Quote.

Your local Agilent sales office or distributor can assist you in defining the appropriate system configuration that best meets your research and analysis needs. Basic configurations are shown below.

Agilent 6100 Quadrupole LC/MS System Bundles
Description Product Number
Agilent 6110 Series LC/MS Electrospray System Bundle
Includes Agilent LC/MS G6110A, electrospray ion source, Agilent LC/MS ChemStation software, and ChemStation data system with PC, display, and printer. System installation and familiarization are included.
G6110AA
Agilent 6120 Series LC/MS Electrospray System Bundle
Includes Agilent LC/MS G6120A, electrospray ion source, Agilent LC/MS ChemStation software, and ChemStation data system with PC, display, and printer. System installation and familiarization are included.
G6120AA
Agilent 6130 Series LC/MS Electrospray System Bundle
Includes Agilent LC/MS G6130A, electrospray ion source, Agilent LC/MS ChemStation software, and ChemStation data system with PC, display, and printer. System installation and familiarization are included.
G6130AA
Agilent 6140 Series LC/MS Electrospray System Bundle
Includes Agilent LC/MS G6140A, electrospray ion source, Agilent LC/MS ChemStation software, and ChemStation data system with PC, display, and printer. System installation and familiarization are included.
G6140AA


Agilent 6100 Quadrupole LC/MS System Non-Bundled Instruments and Accessories
Description Product Number
Agilent 6110 Series LC/MS Quadrupole
Includes calibrant delivery system, ion optics, quadrupole mass analyzer to m/z 1500, vacuum system & electronics.
G6110A
Agilent 6120 Series LC/MS Quadrupole
Includes calibrant delivery system, ion optics, quadrupole mass analyzer to m/z 1500, POS/NEG switching, vacuum system & electronics.
G6120A
Agilent 6130 Series LC/MS Quadrupole
Includes calibrant delivery system, ion optics, quadrupole mass analyzer to m/z 3000, POS/NEG switching, multiple signal capability, vacuum system & electronics.
G6130A
Agilent 6140 Series LC/MS Quadrupole
Includes calibrant delivery system, ion optics, quadrupole mass analyzer to m/z 1350, POS/NEG switching, 10,000 u/s scan speed, multiple signal capability, vacuum system & electronics.
G6140A
Atmospheric Pressure Chemical Ionization (APCI) Source
Includes APCI spray chamber, corona discharge needle, nebulizer, APCI vaporizer, and calibration kit. Can be interchanged with other ion sources on the LC/MSD.
G1947B
Electrospray Ion Source
Includes API-electrospray spray chamber, nebulizer, and calibration kit. Can be interchanged with other ion sources on the LC/MSD.
G1948B
Atmospheric Pressure PhotoIonization Source
Includes APPI spray chamber and nebulizer. Can be interchanged with other ion sources on the LC/MSD.
G1971B
Multimode ESI/APCI Source
Includes ESI/APCI spray chamber, nebulizer, and test mix kit (August 2007 availability for G6110A).
G1978B
Multimode Source Enablement Kit
Includes parts and test mixes for moving the multimode source to a 2nd 6100 Series LC/MS system.
If 2nd instrument is ESI only, order G1978-60451 and G1947-60451.

If 2nd instrument is APCI capable, order G1978-60451.

APCI Source Enablement Kit
Includes parts and test mixes for moving the APCI source to a 2nd 6100 Series LC/MS system.
G1947-60451
Quiet Cover for E1M18 Rough Pump
Installation and familiarization included with new LC/MS orders. Customer installable for installed systems. Standard one-year warranty.
G3199A
Manual Injection for Agilent 6100 Series LC/MS Quadrupoles (All Models)
This functionality is available with the G 1328A kit.
G1328A
8-port Hub for Local Laboratory LAN
For use in controlling Agilent instruments via LAN cabling. Includes J3128A 8-port hub and one 8-meter LAN cable.
G2402A


Agilent 6100 Family LC/MS Quadrupoles and Agilent 1100 Series LC/MS System Upgrade Products
Description Product Number
Mass-Based Fraction Collection Kit for Agilent LC/MSD Systems
Includes I/O accessory module and cables for providing mass-based fraction collection capability with non-Agilent fraction collectors. Compatible with all LC/MSD models except G1946A.
Note: Not for 6100 Series.
G1967B
Mass-Based Fraction Collection Kit for Agilent LC/MSD Systems
Includes I/O accessory module and cables for providing mass-based fraction collection capability for all Agilent systems including fraction collector. Compatible with all LC/MSD models except G1946A.
Note: Now includes components required for the 6100 Series single quadrupole LC/MS
G1968C
LC/MSD LAN Upgrade Kit for G1946A LC/MSD Systems
Includes components to provide control of G1946A LC/MSD systems with ChemStation via LAN.
G2734A
LC/MSD Performance Upgrade Kit for G1946A LC/MSD Systems
Extends the operating range of the G1946A system to G1946B capabilities. Functionality includes multiple-signal data acquisition and analysis (± switching, high/low fragmentor, and SIM/scan).
G2735A
High Performance Upgrade Kit-B for G1946B LC/MSD Systems
Extends the operating range of the G1946B system to G1946D capabilities.
G2735B
High Performance Upgrade Kit-C for G1946C LC/MSD Systems
Extends the operating range of the G1946C system to G1946D capabilities. Functionality include high sensitivity enhancements, extended mass range to m/z 3000 and multiple-signal data acquisition and analysis (± switching, high/low fragmentor, and SIM/scan).
G2735C
High Performance Upgrade Kit for G1956A LC/MSD Systems
Extends the operating range of the G1956A system to G1956B capabilities. Functionality includes high sensitivity enhancements, extended mass range to m/z 3,000, and multiple signal data acquisition and analysis (± switching, high/low fragmentor, and SIM/scan).
G2735D


Agilent LC/MS ChemStation Software and Additional Application Software
Description Product Number
Agilent LC/MSD ChemStation Software
For system control, data acquisition and data evaluation of chromatographic and spectral data for one Agilent 1200 Series LC/MSD or 6100 Series Quadrupole system. Includes DAD as well as MSD spectral analysis capability. Requires, but does not include, Microsoft Windows 2000 (Service Pack 2 minimum, Service Pack 3 recommended) or Microsoft Windows XP (Service Pack 1a). Includes data browser for up to 10 users.
G2710BA
Agilent LC/MSD ChemStation add-on Software
Adds 6100 MS Series system control, data acquisition, and MS spectral data evaluation to an existing 3D LC ChemStation data system. Must have G2170BA and G2180BA Revisions on existing ChemStation. Upgrades to these products will be made automatically by G2715BA.
G2715BA
Agilent LC/MSD Deconvolution & Bioanalysis Software
Adds capability for deconvolution of mass spectra containing multiply-charged ion series produced by electrospray ionization, and for evaluation of MS data from biopolymers such as proteins, peptides, and oligonucleotides. Requires G2710AA LC/MSD ChemStationSoftware or G2715AA LC/MSD Add-on Software module to operate.
G2720BA
Agilent Easy Access Software
Simplifies and automates sample submission, sample management, and reporting. Includes installation and familiarization.
G2725AA
Agilent LC/MSD ChemStation Data Analysis-Only Software
Data analysis-only capability for off-line evaluation of chromatographic, spectral, and 6100 MS Series mass spectral data. Requires, but does not include, Microsoft Windows 2000 (Service Pack 2 minimum, Service Pack 3 recommended) or Microsoft Windows XP (Service Pack 1a).
G2730BA
Agilent ChemStore C/S Database Client Server Software
Includes Microsoft Access-based database for data organization, review, cross-sample reporting, and charting. For Agilent ChemStations for LC, 6100 MS, GC, CE, and A/D.
G2181BA
ChemStation Data Browser Software
Provides data browsing capability for 6100 MS ChemStation files. Requires LC/MSD ChemStation software Revision A.09.03 or higher. One hour of installation and familiarization is included.
G2727AA
Purification Software and Solutions
Click here for information about purification software and complete purification solutions.



 
 
grey1
related_bottom_left clear clear clear
clear
grey2