Specifications: 1200 Series Fraction Collector (AS)

Delay volume

Approximately 50 μL

Maximum system flow

10 mL/min, or up to 100 mL/min with semiprep
needle and 0.8 mm tubing

Fraction containers

  • Shallow or deep well plates up to 48 mm height
    (96 or 384 format)
  • Test tubes up to 48 mm height, or up to 75 mm
    height with semiprep needle
  • Autosampler vials (2 mL and 6 mL)
  • Eppendorf safe-lock tubes (0.5 mL, 1.5 mL , 2.5 mL)

Fraction trays

Full trays (cover complete fraction collector)

  • 4 well plates
  • 40 x 30 mL test tubes (30 mm od, 48 mm height)
  • 60 x 20mL test tubes (25 mm od, 48 mm height)
  • 126 x 8mL test tubes (16 mm od, 48 mm height)
  • 215 x 5 mL test tubes (12 mm od, 48 mm height)

  • 2 well plates + 10 x 2 mL vials ( + one possible additional half tray)
  • 2 well plates + 10 funnels for collection in external containers (+ one additional half tray)
  • 100 x 2 mL vials (+ one possible additional half tray)

Half trays (up to 3 per fraction collector)

  • 40 funnel tray
  • 15 x 6 mL vial
  • 40 x 2 ml vial

Tube plates for well plate trays

(2 or 4 per fraction collector depending on well plate tray):
Eppendorf safe-lock tubes (27 x 0.5 ml, 1.5 ml or 2.5 ml)
24 test tubes (18 mm OD)
54 x 2 ml vial
15 x 6 ml vial

Cooling

Optional

Specifications: 1200 Series Fraction Collector (PS)

Delay volume

Approximately 500 μL

Maximum system flow

100 mL/min

Fraction containers

  • 96 deep well plates up to 48 mm height
  • Test tubes, minimum 48 mm up to maximum
    100 mm height (up to 45 mL)
  • Autosampler vials (2 mL and 6 mL)

Fraction trays

Full trays

  • 4 well plates
  • 40 x 45 mL test tubes (30 mm OD, 100 mm height)
  • 60 x 32 mL test tubes (25 mm OD, 100 mm height)
  • 126 x 13 mL test tubes (16 mm OD, 100 mm height)
  • 215 x 7.5 mL test tubes (12 mm OD, 100 mm height)

  • 2 well plates + 10 x 2 mL vials (+ one possible additional half tray) 100 x 2 mL (+ one possible additional half tray)

Half trays (up to 3 per fraction collector)

15 x 6 mL vial
40 x 2 ml vial

Tube plates for well plate trays

(2 or 4 per fraction collector depending on well plate tray):
Eppendorf safe-lock tubes (27 x 0.5 ml, 1.5 ml or 2.5 ml)
24 test tubes (18 mm OD)
54 x 2 ml vial
15 x 6 ml vial

Cooling

Optional

Note: 2 ml vials are possible with PS fraction collector but not recommended

Specifications for both Fraction Collectors (AS/PS)

Trigger modes

Time slices and peak (threshold, up-/downslope, upper threshold and timetable), Boolean logic for different detector signals, combination of different modes, manual trigger (supported with 1200 Series Instant Pilot)

Trigger source

Agilent 1200 Series VWD (only for AS), MWD and DAD detectors, Agilent 6100 Series Quadrupole LC/MS, third party detectors (require UIB)

Diverter valve

3/2 valve, switching time < 100 ms

Max. pressure

6 bar

Max. capacity

3 fraction collectors connected in parallel through a 12-position/13-port selection valve

Environment

4 – 55 °C constant temperature, < 95% humidity (non-condensing)

 
 