1200 Series Detectors - Overview 

white
clear clear clear clear clear

grey1
Literature Library
Technical Support
Education & Events

grey1


The Agilent 1200 Series detectors provide high sensitivity UV-Visible, fluorescence, refractive index, and evaporative light scattering detection for all your liquid chromatography needs.

High Sensitivity UV-Vis Detection

 

Wavelength range

Number of signals

Max. sampling rate

Agilent 1290 Infinity Diode Array Detector
A new optical design based on the Max-Light cartridge cell with optofluidic waveguides offers a new level of UV-sensitivity and baseline robustness, including fast spectral acquisition at up to 160 Hz data rates.

190 – 640 nm

8 signals

160 Hz

Agilent 1200 Series Diode Array Detector SL
Detects full spectra and 8 signals with up to 80 Hz sampling rate for ultimate confidence in ultra-fast LC. New data recovery card (DRC) and radio frequency identification (RFID) technology provide new levels of data security and traceability.

190 – 600 nm

8 signals

80 Hz

Agilent 1200 Series Diode Array Detector
Provides full power of multiple wavelength detection and spectral information with high resolution and sensitivity. Patented RFID tracking technology for flow cells and UV lamp offers a new level of data traceability.

190 – 600 nm

8 signals

20 Hz

Agilent 1200 Series Multiple Wavelength Detector SL
Permits detection of up to 8 signals with up to 80 Hz sampling rate, providing uncompromised compatibility with the analysis speed delivered by ultra-fast LC. Embedded data recovery gives unique "data-never-lost insurance". New data recovery card (DRC) and radio frequency identification (RFID) technology provide new levels of data security and traceability.

190 – 600 nm

8 signals

80 Hz

Agilent 1200 Series Multiple Wavelength Detector
Allows simultaneous detection of up to eight different wavelengths without sacrificing sensitivity. Patented RFID tracking technology for flow cells and UV lamp offers a new level of data traceability.

190 – 600 nm

8 signals

20 Hz

Agilent 1200 Series Variable Wavelength Detector SL Plus
Enables high-speed UV detection with up to 160 Hz sampling rate for highest performance with minimum baseline noise and drift in ultra-fast LC applications. Electronic temperature control (ETC) for baseline stability even under fluctuating ambient temperature and humidity conditions. New data recovery card (DRC) and radio frequency identification (RFID) technology provide new levels of data security and traceability.

190 – 600 nm

1 signal

160 Hz

Agilent 1200 Series Variable Wavelength Detector (VWD)
New dimension in minimum baseline noise and drift for lowest detection limits with excellent robustness. Electronic temperature control (ETC) for baseline stability even under fluctuating ambient temperature and humidity conditions. Patented RFID tracking technology for flow cells and UV lamp offers a new level of data traceability.

190 – 600 nm

1 signal

20 Hz


Fluorescence Detection  

Agilent 1200 Series Fluorescence Detector
Comes with a unique design that provides high-speed, high sensitive, multisignal and full spectral detection without the need to reduce or stop the flow, fast method optimization by spectral 3D and contour plots, straightforward operation and maintenance, and built-in features for GLP compliance.

Refractive Index Detection 

Agilent 1200 Series Refractive Index Detector
Ideal for fast and reliable HPLC results when routinely analyzing non-UV absorbing substances such as carbohydrates, lipids and polymers. It is also the detector of choice for gel permeation chromatography and used in the Agilent 1200 Series GPC-SEC solution.

Evaporative Light Scattering Detection 

Agilent 1200 Series Evaporative Light Scattering Detector 
Detects any compound that is less volatile than the mobile phase. The ELSD provides an essentially universal measurement under isocratic and gradient conditions that does not depend on a compound´s absorbance, fluorescence, or electro-activity. Low temperature evaporation technology enables detection of semi-volatile and thermo-sensitive compounds at low levels.

 
 