Agilent 1200 HPLC-Chip/MS System

Product Description

Part Number

Notes

HPLC-Chip/MS Interface or Chip-Cube
For use with all Agilent 6000 Series Mass Spectrometers.

Includes HPLC-Chip Cube, MS installation kit, orthogonal dual electrode nanospray ion source with camera and monitor, ion source top plate with brushes for operation in chemical background reduction mode, Protein ID Chip #1 and MS calibration and diagnostic chip. IRM source top plate and chemicals are included when ordering TOF and QTOF MS systems. Also includes all parts and flow control module for air make-up to the N2 MS drying gas line when operating the HPLC-Chip ion source in chemical background reduction mode.

G4240A

Supported in Agilent ChemStation and Mass Hunter software. Requires a source of clean dry air with a pressure regulator of least 100 psi (8 bar) capacity and ¼ inch Swagelok connector for operation in chemical background reduction mode.

IRM (Internal Reference Mass) for the chip nanospray source and reference compounds are now included with G4240A HPLC-Chip/MS interface when it is ordered with TOF or QTOF MS systems.

HPLC-Chip/MS installation.

HPLC-Chip/MS familiarization at installation.

#44K

#44L

Installation and familiarization are included in selected countries. Please consult your Agilent Sales Specialist for details.


 HPLC-Chip/MS Interface Accessories

Product Description

Part Number

Notes

Chemical background reduction site preparation kit.
Provides necessary parts and flow control module for air make-up to the N2 MS drying gas line when operating the HPLC-Chip ion source in chemical background reduction mode.
Requires a source of clean dry air with a pressure regulator of least 100 psi (8 bar) capacity and ¼ inch Swagelok connector.

G1995A

For customers using liquid   Nor Ngenerators without N2 purity indicator or that are using an N2 source shared between several MS systems. Not required for G4240A HPLC-Chip/MS systems shipped after February 01, 2007.

HPLC-Chip enablement kit for Agilent TOF MS
For use with Agilent G3250AA TOF MS.

Provides required ion source upgrade parts and software for G3250AA TOF’s shipped prior to June 2006, (SN < US62400800).

G1984A

Syringe pump required to infuse reference mass compound (PN 3162-0178). Also requires capillary adaptor (P/N 9301-1201) and power cord meeting local power requirements.

Replacement top plate for HPLC-Chip nanoelectrospray source

G1982-60359

For use with G4240A HPLC-Chip/MS interface only

IRM high mass compound (HP-1221)

G1982-85001

Please consult the G4240 HPLC-Chip/MS Interface with 6510 Q-TOF or 6210 TOF Internal Reference Mass User Guide.

IRM high mass solvent (Fluorinert™ FC-70)

G1982-85002

IRM low mass compound (methyl stearate)

G1982-85003

Inline Micro filter kit.
Includes pre-assembled inline filter, 4 replacement 0.5 µm PEEK filter frit fittings, connection capillary and micro fittings. Approximate delay volume of 240 nL.

5067-1582

An in-line filter is strongly recommended for biofluid samples or samples with high levels of particulates or containing high levels of proteins, lipids or other materials. The filter is installed in-line between the autosampler and the HPLC-Chip Cube.

Replacement 0.5 µm PEEK filter frit fittings, pack of 10.

5067-1584

Replacement micro fingertight fittings,
790 µm ID, PEEK. Pack of 10.

5067-1585

Replacement connection capillary,
100 mm x 25 µm, 1/32” OD. PEEK/fused silica.

G1375-87320

Phosphochip reagent pack
Ready to use phosphopeptide elution buffer and column regeneration mix, and lyophilized conditioning/standard mix

400600

For use with Phosphochip

PEEK sample transfer capillary
(25 µm x 100 cm)

G4240-87309

Recommended for Phosphochip use or other applications for inertness or high pH operation up to pH10

PEEK capillary for use with micro inline filter (25 µm x 10 cm)

G4240-87310



HPLC Chips

Chip Name

Part Number

Notes

Original

HPLC-Chip II

Calibration & Maintenance

Calib-Chip (II)

G4240-61001*

G4240-61010***

MS calibration and diagnostic chip

FIA-Chip (II)

G4240-61002*

G4240-61015***

Dedicated infusion and flow injection chip

Chip Name

Part Number

Notes

Original

HPLC-Chip II

Proteomics

ProtID-Chip-43 (II)

G4240-62001**

G4240-62005***

Rapid Protein ID, 43mm 300 A C18 chip w/40 nL trap column

ProtID-Chip-150 (II)

G4240-62002**

G4240-62006***

Better Separation, 150mm 300 A C18 chip w/ 40 nL trap column

Large capacity Chip (II)

G4240-63001 SPQ110****

G4240-62010

High Capacity Loading, 150mm 300 A C18 chip w/ 160 nL trapp. col

Phosphochip (II)

 

--

G4240-62020

PTM analysis, 150mm 300 A C18 chip w/ RP-TiO2-RP trap col

Chip Name

Part Number

Notes

Original

HPLC-Chip II

Small Molecule Analysis

SmMol-Chip-43 (II)

G4240-65001*

G4240-65005***

Rapid analysis, 43mm 80 A C18 chip with 40 nL trap col

UHC-Chip (II)

G4240-63001 SPQ115****

G4240-65010

150 mm 80 A C18 chip with 500 nL trap col

Chip Name

Part Number

Notes

Original

HPLC-Chip II

Other Applications (carbohydrates, nucleotides, etc.)

PGC-Chip (II)

G4240-62003*

G4240-64010***

43mm porous graphitized carbon chip with 40 nL trap col

Chip Name

Part Number

Notes

Original

HPLC-Chip II

Custom Chips

Dir-Inj-Chip (II)

G4240-63001 SPQ100***

150mm 300 A C18 chip w/ 16 nL void

Protein-Chip (II)

G4240-63001 SPQ105***

43mm 300 A C8 chip w/40 nL trap column

Customizable Chip (you name it)

Special SPQ Number

Design your own chip and ask for a special quote

Instructions for custom chip quotes:

Please email chip_pdl-wadquotes@agilent.com for a special quote or any custom chip order (P/N G4240-63001). Please copy your Agilent account manager/product specialist on the email. A special SPQ (special price quote) number will be issued in the quote. A minimum 2 custom chips per order is required.

Please provide the following information:

  • Stationary phases information (most phases offered from Agilent columns will be available on chip, for special phase materials, customer may need to ship the material to Agilent in Germany)
    • Enrichment column (phase, pore size, and particle size, i.e. C18, 300 Å, and 5 µm)
    • Separation column (same as above)
  • Column sizes for enrichment column (40 nL, 160 nL or 500 nL) and separation column
    (43 mm or 150 mm)
  • Please reference SPQ numbers for each chip type in PO (purchase order)

Delivery of chips is 4-6 weeks after receipt of order.



 NOTES

Availability
*Obsolete Dec. 1st 2009;** Obsolete Mar. 1st 2010; *** Available Dec. 1st 2009;
****Obsolesced June 1st 2009.

 
 