Select a Country or Area
|
Contact Us
Products & Services
Technical Support
Solutions
Buy
About Agilent
Go to Part Number Search
Home
>
Products & Services
>
Instruments & Systems
>
Liquid Chromatography
>
1200 Series GPC-SEC Analysis System
Register
|
Login
1200 Series GPC-SEC Analysis System
Easy and reliable polymer characterization
The Agilent 1200 Series HPLC system is ideally suited to GPC-SEC analysis. The precision of its isocratic solvent delivery system provides the constant, stable flow rate that is essential to maintain the high resolution of the GPC-SEC column. The high flow precision and the excellent temperature stability of the Agilent 1200 Series thermostatted column compartment ensure highest accuracy and precision of molecular weight determinations. Column temperature stability is guaranteed from 10 °C below ambient to 80 °C or alternatively to 100°C.
Buy
Ordering Details
Request A Quote
Where To Buy
Store Home
Related Information
Literature Library
Data Sheet
Specifications
more...
Technical Support
Frequently Asked Questions
Downloads and Utilities
Parts Information
more...
Education & Events
Classroom Training Courses
Customized On-Site Training
e-Seminars
more...
Features
Provides interactive and automated GPC-SEC analysis including recalibration and GPC reporting.
Simplifies retrieval of GPC-SEC data.
Allows internal standard and detector delay corrections and includes narrow, broad, universal and integral calibration.
Complete with validation and automated instrument verification procedures and fully compliant with ISO/EN 13885 and DIN 55672 GPC standards.
An extended choice of data evaluation methods:
Automated use of fixed settings for baseline and evaluation range, based on retention time or molecular weight, automated integrator-based baseline setting, Interactive optimization of baseline settings independent of evaluation range for mass distribution.
Automatic evaluation of each peak of a multi-peak chromatogram.
Dextran evaluation according to Pharmacopeia.
Tabular slice reports, containing, for example, retention time, molar mass and the slices' contribution to the differential and cumulative molar mass distributions in ASCII format for export to calculation and reporting programs.
Extended calibration information: Curve coefficients and the least squares fit for fast check of polynomial fit. Curve slope and the percentage deviation between each calibration point and the curve for a thorough control of the polynomal fit as required by International GPC standards.
Convenient flow rate entry and automatic elution volume calculation for third-party solvent delivery.
Columns & Supplies
LC and LC/MS Columns
LC and LC/MS Consumables
Services
Compliance Services
Instrument Services
Software Services
Specialized Services
Lifecycle Services
Additional Information
1200 Series Rapid Resolution System
Announcements
Upcoming Events
NEW Podcast Series – Tips and Tricks for HPLC
More...