| Description |
Product number |
Agilent 1200 Series capillary pump Includes capillary pump with 20-µL flow sensor, solvent cabinet, four solvent bottles, solvent selection valve and 1-m CAN cable, and G1379A micro vacuum degasser |
G1382A |
Agilent 1200 Series micro well-plate sampler Includes micro well-plate autosampler with well-plate tray, electrically actuated Rheodyne micro injection valve and 0.5-m CAN cable |
G1377A |
Thermostat for 1200 Series samplers (well-plate samplers and autosamplers) Includes Peltier device to control the temperature of the Agilent 1200 Series autosampler tray |
G1330B |
High flow rate conversion kit (for flow rates up to 2.5 mL/min) Includes fused silica/PEEK: 1 ea 125 µm x 55 cm, 2 ea 100 µm x 20 cm, 1 ea 100 µm x 55 cm, 1 loop cap 0.25 m x 180 cm, SS cap: 0.17 x 90 mm, 0.17 x 380 |
5065-4495 |
Column switching valve kit micro LC Includes 6-port micro-switching valve, 4 PEEK/fused Silica capillaries, 50-µm id, 6 PEEK fittings and plugs |
5065-4447 |
Agilent 1200 Series 2-port/6-port micro valve Includes valve, mounitng parts for column organizer G1383A and accessory kit. |
G1162A |
Agilent 1200 Series 2-port/10-port micro valve Includes valve, mounting parts for column organizer G1383A and accessory kit. |
G1163A |
Agilent 1200 Series thermostatted column compartment Includes column compartment with two heat exchangers for solvent pre-heating, column identification module and CAN cable. |
G1316A |
Micro 6-port valve option Includes micro column switching valve and connection capillaries. |
G1316A#056 |
Agilent 1200 Series diode-array detector SL Provides 80 Hz data acquisition rate and 128 MB compact flash card for data recovery. Includes long-life deuterium and tungsten lamp. No flow cell included. |
G1315C |
500-nL flow cell Contains quartz flow cell with 10-mm pathlength, 500-nl volume, nickel silver steel housing, RFID tag, connecting caps. Pressure tight to 50 bar. |
G1315C#014 |
80-nL flow cell Contains quartz flow cell with 6-mm path length, 80-nl volume, nickel silver steel housing, RFID tag, connecting caps. Pressure tight to 50 bar. |
G1315C#012 |
Capillary LC/MS Nebulizer Assembly Includes replacement stainless steel needle, needle holder, tools for replacement, instructions. Connecting capillary between LC and MS nebulizer. |
G1385A |
|
|