Agilent Technologies LSCA - Our measure is your success
clear
white
clear
white
clear

GC/MS

white
clear clear clear clear clear

grey1
Literature Library
Technical Support
Education & Events

grey1
 

Agilent Triple Quad GC/MS Techniques & Operation 


3200 (USD) R1718A  Day(s) Hands-On Operation 
3700 (CAD)
Description:

Training Units   32 (US)  |  37 (CA)         What are Training Units?

This 4 day, hands-on course will give analysts the experience to develop MRM methods using the Agilent Triple Quadrupole GC/MS.  The topics include a complete look at data acquisition and scan types, MassHunter Qualitative and Quantitative Analysis software packages, reporting and routine maintenance of the instrument.

Outline:

GC-QQQ Principles
Agilent 7000A Instrumentation and Software
Tuning and Calibrating the Instrument
            • Laboratory – Tuning the Instrument
Agilent 7890 GC Essentials
            • Laboratory – Setting up the GC
Method Development I – MS1 Acquisition
            • Laboratory – Perform MS1 Acquisition and select Precursor ions
Basic Qualitative Analysis
            • Laboratory – Basic Qualitative Analysis features
Qualitative Analysis Methods
            • Laboratory – Automate qualitative analysis
Advanced Qualitative Analysis – Library Searching, Find Compounds, Deconvolution.
            • Laboratory – Add deconvolution and library searching to your data analysis methods
Basic Quantitative Analysis
            • Laboratory – Develop a quantification method and analyze the batch
Advanced Quantitative Analysis
            • Laboratory – Manipulate the batch analysis
Sequencing
Method Development II – Optimization and the Optimization Assistant
            • Laboratory – Perform product ion scans and uses the Optimization Assistant and Quantitative
              Analysis software to optimize results
Method Development III – MRM Method
            • Laboratory – Perform MRM analysis and use the Optimization Assistant and Quantitative
              Analysis software to optimize results.
            • Laboratory – Develop an MRM Quantitative Analysis method and execute.
Reporting
            • Laboratory – Generate Qualitative and Quantitative Reports and customize a report template.
Maintenance
            • Laboratory – optional – source cleaning

Prerequisites:
1 month experience using the instrument and basic mass spectrometry and gas chromatography experience.  If you have no GC or MS experience, please take H4040A before attending this course.
Equipment: Agilent 7890 and Agilent 7000A QQQ GC/MS with Mass Hunter software. 
Student Profile: An Agilent 7000A QQQ GC/MS user who has responsibility for routine sample analysis. 

Course Calendar:
GA, AlpharettaFebruary 14, 2012 - February 17, 2012
GA, AlpharettaMarch 27, 2012 - March 30, 2012
GA, AlpharettaMay 01, 2012 - May 04, 2012
GA, AlpharettaJune 05, 2012 - June 08, 2012
GA, AlpharettaAugust 07, 2012 - August 10, 2012
GA, AlpharettaSeptember 18, 2012 - September 21, 2012
GA, AlpharettaOctober 23, 2012 - October 26, 2012
GA, AlpharettaDecember 04, 2012 - December 07, 2012
GA, AlpharettaJanuary 29, 2013 - February 01, 2013

On Demand

To register your interest in a training course simply click on the relevant city / date or "On Demand" link above.


grey1
related_bottom_left clear clear clear
clear clear
grey2
Please select your country:
 
   
Registration   |  Login Benefits of Registration