Agilent 7500 Series ICP-MS Techniques and Operation with MassHunter 


2722 (USD) M8974A  Day(s) Hands-On Operation 
3228 (CAD)
Description:
The course is designed as a beginner to intermediate level class for Agilent customers and is aimed at providing a comprehensive overview of the Agilent 7500 Series ICP-MS technique and Agilent’s MassHunter Data Analysis software.  Some advanced topics (e.g., laser ablation, direct organic solvent sampling, and chromatography sample introduction) are introduced, but not covered in depth.

Outline:

Introduction
Fundamentals of ICP-MS
Agilent 7500 system Hardware Control
Plasma ignition and normal mode tuning
       • Laboratory:  Start Up and Tuning
ICP-MS Interferences
Octopole Reaction System (ORS)
       • Laboratory:  Tuning in ORS modes
Acquisition Methods and Sequences
       • Laboratory Acquire a Simple Mass Spectrum
       • Laboratory Multi-Tune Method and Sequence
Data Analysis Methods and Principles of Quantification
       • Laboratory Data Analysis Set up and Evaluation
MassHunter Analysis Capabilities
Agilent 7500 Basic Maintenance
Introduction to Hyphenated ICP-MS Techniques
ICP-MS Resources
       • Appendix:  Time Resolved Analysis
       • Appendix:  Analysis of Trace Metals in Organic Samples
       • Appendix:  Integrated Sample Introduction System
       • Appendix:  Ultra-Trace Level Ultra-High Purity Applications

Prerequisites:
None
Equipment: Agilent 7500 ICP-MS system with ChemStation and MassHunter Data Analysis software. 
Student Profile: An analyst or chemist who has responsibility for operation and maintenance of the Agilent 7500 ICP-MS for routine and non-routine samples.  (See "Additional Details" below.) 

Course Calendar:
MO, St. LouisDecember 08, 2009 - November 05, 2010
MO, St. LouisApril 13, 2010 - November 05, 2010
MO, St. LouisAugust 31, 2010 - November 05, 2010

To register your interest in a training course simply click on the relevant city / date or "On Demand" link above.


Additional Details:  
Students that gain the most from this class will minimally have some experience with (1) analytical techniques; such as ICP-OES or organic mass spectrometry, (2) have experience with ICP-MS systems but not with ChemStation software, (3) persons requiring a solid overview of the technique, e.g., lab managers, graduate students. 

For the 7700 Series ICP-MS, see R1777A.