Agilent Technologies LSCA - Our measure is your success
clear
white
clear
white
clear

Agilent 7890A GC System 

white
Agilent 7890A GC System 
All the elements for perfect chemistry. 
Adding an exciting new chapter to a 40-year history of GC leadership, Agilent’s 7890A GC gives you everything you need to take your lab to the next level of GC and GC/MS performance, including advanced separation capabilities, powerful new productivity enhancements and real-time self-monitoring instrument intelligence. Faster oven cool-down and backflushing let you get more done in less time, at a lower cost per sample. 5th-generation Electronic Pneumatics Control (EPC) and digital electronics set a new benchmark for pressure setpoint and retention time locking precision (0.001 psi) and help make the 7890A our most dependable GC ever.
Buy
 


Related Information

Features
  • Multimode inlet (MMI) includes spit/splitless, temperature ramping and large volume injection capabilities.
  • Convenient new Turn-Top design is built into each split/splitless (SSL) and Multimode inlet, allowing you to change liners in less than 30 seconds—without special tools or training
  • Breakthrough Capillary Flow Technology enables leak-free in-oven connections, enhances productivity and data integrity via backflushing and offers versatile, robust solutions for complex GC analyses.
  • Low Thermal Mass (LTM) technology provides direct rapid heating and cooling of capillary columns for extremely fast analytical cycle times and higher productivity
  • Blos NPD available for more stable operation and longer lifetime
  • Agilent 7693 Series Automatic Liquid Sampler offers for the fastest injection times of any GC autosampler, plus dual simultaneous injection, 150-vial capacity and enhanced sample preparation capabilities
  • Powerful, chromatographer-friendly GC software simplifies methods setup and system operation, and minimizes training time.  Other GC software packages including Retention Time Locking (RTL) and Lab Advisor can further boost chromatographic capabilities.
  • Built upon proven 6890 inlets, detectors and GC oven, you can transfer methods to the 7890A GC with complete confidence
  • Agilent offers a complete selection of gas chromatography accessories that let you configure the exact system to meet your lab’s needs

Announcements

clear
grey2