USP Packing Materials |
Columns |
Particle Size (µm) |
Pore Size (Å) |
|
L1 |
Octadecyl silane chemically bonded to porous silica or ceramic micro-particles, 3 to 10 µm in diameter |
ZORBAX Eclipse Plus C18 ZORBAX Eclipse XDB-C18 ZORBAX SB-C18 ZORBAX Rx-C18 ZORBAX Extend-C18 ZORBAX ODS ZORBAX ODS Classic LiChrosorb RP-18 LiChrospher RP-18 Purospher RP-18/-e Superspher RP-18/-e Nucleosil 100-5 C18 |
3.5, 5 3.5, 5 3.5, 5 3.5, 5 3, 5 5 5 5, 10 5 5 4 5 |
95 80, 300 80, 300 80, 300 120 70 70 100 100 100 100 100 |
|
L2 |
Octadecyl silane chemically bonded to silica gel of a controlled surface porosity that has been bonded to a solid spherical core, 30 to 50 µm in diameter |
N/A |
|
|
|
L3 |
Porous silica particles, 5 to 10 µm in diameter |
ZORBAX SIL ZORBAX Rx-SIL LiChrospher 60 Si |
5 3.5, 5 5 |
70 80, 300 60 |
|
L4 |
Silica gel of controlled surface porosity bonded to a solid spherical core, 30 to 50 µm in diameter |
Custom Order |
|
|
|
L5 |
Alumina of controlled surface porosity bonded to a solid spherical core, 30 to 50 µm in diameter |
N/A |
|
|
|
L6 |
Strong cation-exchange packing: sulfonated fluorocarbon polymer coated on a solid spherical core, 30 to 50 µm in diameter |
N/A |
|
|
|
L7 |
Octyl silane chemcially bonded to totally porous microsilica particles, 5 to 10 µm in diameter. |
ZORBAX C8 ZORBAX Eclipse Plus C8 ZORBAX Eclipse XDB-C8 ZORBAX SB-C8 ZORBAX Rx-C8 LiChrosorb RP-8 LiChrospher RP-8 LiChrospher RP select B |
5 3.5, 5 3.5, 5 3.5, 5 3.5, 5 5 5 5 |
70 80 80, 300 80, 300 80, 300 100 100 60 |
|
L8 |
An essentailly monomolecular layer of aminopropyl-silane chemcially boneded to totally porous silica gel support, 10 µm in diameter. |
ZORBAX NH2 LiChrospher NH2 |
5 5 |
70 100 |
|
L9 |
10 µm irregular, totally porous silica gel having a chemically bonded, strongly acidic cation-exchange coating. |
ZORBAX SCX SynChropak SCX |
5 spherical 6.5 |
300 300 |
|
L10 |
Nitrile groups chemically bonded to porous silica particles, 3 to 10 µm in diameter. |
ZORBAX CN ZORBAX SB-CN ZORBAX Eclipse XDB-CN LiChrospher CN |
5 3.5, 5 3.5, 5 5 |
70 80, 300 80 100 |
|
L11 |
Phenyl groups chemically bonded to porous silica particles, 5 to 10 µm in diameter. |
ZORBAX Phenyl ZORBAX SB-Phenyl ZORBAX Eclipse XDB Phenyl
|
5 3.5, 5 3.5, 5 |
70 80 80 |
|
L12 |
Strong anion-exchange packing made by chemically bonding a quaternary amine to a solid silica spherical core, 30 to 5 µm in diameter |
Accubond Bulk SAX, 25 g bottle |
|
|
|
L13 |
Trimethylsilane chemically bonded to porous silica particles, 3 to 10 µm in diameter. |
ZORBAX TMS
|
5 |
70 |
|
L14 |
Silica gel 10 µm in diameter having a chemically bonded, strongly basic quaternary ammonium anion-exchange coating. |
ZORBAX SAX SynChropak SAX |
5 6.5 |
70 300 |
|
L15 |
Hexyl silane chemically bonded to totally porous silica particles, 3 to 10 µm in diameter |
N/A |
|
|
|
L16 |
Dimethyl silane chemically bonded to totally porous silica particles, 3 to 10 µm in diameter. |
N/A |
|
|
|
L17 |
Strong cation exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 7 to 11 µm in diameter. |
N/A |
|
|
|
L18 |
Amino and cyano groups chemically bonded to porous silica partices 5 to 10 µm in diameter. |
N/A |
|
|
|
L19 |
Strong cation exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the calcium form, 9 µm in diameter. |
N/A |
|
|
|
L20 |
Dihydroxypropane groups chemically bonded to porous silica particles, 3 to 10 µm in diameter |
LiChrospher Diol |
5 |
100 |
|
L21 |
A rigid, spherical styrene-divinylbenzene copolymer, 5 to 10 µm in diameter. |
N/A |
|
|
|
L22 |
A cation group resin made of porous polystyrene gel with sulfonic acid groups, about 10 µm in size. |
N/A |
|
|
|
L23 |
An ion exchange resin made of porous polymethacrylate or polyacrylate gel with quaternary ammonium groups, about 10 µm in size. |
N/A |
|
|
|
L24 |
A semi-rigid hydrophilic gel consisting of vinyl polymers with numerous hydroxyl groups on the matrix surface, 32 to 63 µm in diameter. |
N/A |
|
|
|
L25 |
Packing having the capacity to separate compounds with a MW range from 100 to 5000 da (as determined by polyethylene oxide), applied to neutral, anionic and cationic water-soluable polymers. |
PL aquagel-OH |
|
|
|
L26 |
Butyl silane chemically bonded to totally porous silica particles, 5 to 10 µm in diameter. |
N/A |
|
|
|
L27 |
Porous silica particles, 30 to 50 µm diameter |
AccuBond Bulk SIL, 25 g bottle |
|
|
|
L28 |
A multifunctional support, which consists of a high purity, 100Å, spherical silica substrate that has been bonded with anionic (amine) functionality in addition to conventional reversed-phase C8 functionality. |
N/A |
|
|
|
L29 |
Gamma alumina, reversed phase, low carbon percentage by weight, alumina-based polybutadiene spherical particles, 5µm diameter with a pore diameter of 80Å. |
N/A |
|
|
|
L30 |
Ethyl silane chemically bonded to a totally porous silica particle, 3 to 10 µm in diameter |
N/A |
|
|
|
L31 |
A strong anion-exchange resin-quaternary amine bonded on latex particles attached to a core of 8.5 µm macroporous particles having a pore size of 2000Å and consisting of ethylvinylbenzene cross-linked with 55% divinylbenzene. |
N/A |
|
|
|
L32 |
A chiral ligand-exchange packing- L-proline copper complex covanlently bonded to irregularly shaped silica particles, 5 to 10 µm in diameter. |
N/A |
|
|
|
L33 |
Packing having the capacity to separate proteins by molecular size over a range of 4,000 to 400,000 daltons. It is spherical, silica-based, and processed to provide pH stability. |
ZORBAX GF-250 |
4 |
150 |
|
L34 |
Strong cation exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the lead form, 9µm in diameter. |
N/A |
|
|
|
L35 |
A zirconium-stabilized spherical silica packing with a hydrophilic (diol-type) molecular monolayer bonded phase |
ZORBAX GF-250 ZORBAX GF-450 |
4 6 |
150 300 |
|
L36 |
L-Phenylglycine-3, 5-dinitrobenzoyl on 5 µm amino propyl silica. |
N/A |
|
|
|
L37 |
Polymethacrylate gel packing having the capacity to separate proteins by molecular size over a range of 2,000–40,000Da MW |
N/A |
|
|
|
L38 |
Methacrylate-based size exclusion packing for water-solubles |
N/A |
|
|
|
L39 |
Hydrophilic polyhydroxymeth-acrylate gel of totally porous spherical resin |
N/A |
|
|
|
L40 |
Cellulose tris-3,5-dimethylphenylcarb-amate coated porous silica particles, 5 to 20 µm in diameter |
N/A |
|
|
|
L41 |
Immobilized alpha-acid glyco-protein on spherical silica particles, 5 µm in diameter |
N/A |
|
|
|
L42 |
Octlysiilane and octadecylsilane groups chemically bonded to porous silica particles |
N/A |
|
|
|
L43 |
Pentafluoropehnyl groups chemically bonded to silica particles 5 to 10 µm in diameter |
N/A |
|
|
|
L44 |
A multifunctional support, which consists of a high purity, 60Å spherical silica substrate, that has been bonded with a cationic exchanger, sulfonic acid functionality in addition to a conventional reversed phase C8 functionality. |
N/A |
|
|
|
L45 |
Beta cyclodextrin bonded to porous silica particles, 5 to 10 µm in diameter. |
ChiraDex Chiral |
5 |
|
|
L46 |
Polystyrene/divinylbenzene substrate agglomerated with quarternary amine functionalized latex beads, 10µm in diameter. |
N/A |
|
|
|
L47 |
High capacity anion exchange microporous substrate, fully functionalized with a trimethyl-amine group, 8 µm in diameter. |
N/A |
|
|
|
L48 |
Sulfonated, cross-linked polystyrene with an outer layer of submicron, porous, anion-exchange microbeads, 15 µm in diameter. |
N/A |
|
|
|
L49 |
Amylose tris-3, 5-dimethylphenyl-carabamate-coated, porous, spherical, silica particles, 5 to 10 µm in diameter. |
N/A |
|
|
|
L50 |
A strong cation exchange resin made of porous silica with sulfopropyl groups, 5 to 10 µm in diameter. |
ZORBAX 300SCX SynChropak SCX |
5 5 |
300 300 |
|
L51 |
A reversed-phase packing made by coating a thin layer of polybutadiene on to spherical porous zirconia particles, 3 to 10 µm in diameter. |
N/A |
|
|
|
L52 |
Multifunction resin with reversed-phase retention and strong anion-exchange functionalities. The resin consists of ethylvinyl-benzene, 55% cross-linked with divinylbenzene copolymer, 3 to 15 µm in diameter, and a surface of not less than 350m2/g, substrate is coated with quarternary ammonium functionalized latex particles consisting of styrene cross-linked with divinylbenzene. |
N/A |
|
|
|
L53 |
An anion-exchange resin consisting of rigid, spherical styrene-divinylbenzene copolymer with trimethylammonium groups at a loading of about 2meq per g, 3 to 29 µm in diameter. |
N/A |
|
|
|
L54 |
Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the sodium form, about 7 to 11 µm in diameter. |
N/A |
|
|
|
L55 |
Weak cation-exchange resin consisting of ethylvinylbenzene, 55% cross-linked with divinyl-benzene copolyme, 3 to 15 µm in diameter. Substrate is surface grafted with carboxylic acide and/or phosphoric acid functionalized monomers. Capacity not less than 500 µeq/column. |
N/A |
|
|
|
L56 |
Propyl silane chemically bonded to totally porous silica particles, 3 to 10 µm in diameter |
SB-C3 |
3.5, 5 |
80 |
|
L57 |
A chiral-recognition protein, ovomucoid, chemically bonded to silica particles, about 5 µm in diameter, with a pore size of 120Å |
Ultron ES-OVM |
5 |
120 |