7000B Triple Quadrupole GC/MS System 
Product Description
This product has been discontinued.

The 7000B Triple Quadrupole GC/MS System has been superseded by the 7000C Triple Quadrupole GC/MS System. Coupled with the 7890B GC, the 7000C MS works in perfect harmony to enhance productivity.

The 7000B Triple Quadrupole GC/MS System has been discontinued since: Sept. 1st, 2013 and is no longer available for purchase.

For further details please refer to:

7000C Triple Quadrupole GC/MS System

The Agilent GC/MS online store - for information on GC/MS systems, parts, accessories and software
  • High sensitivity EI source and ramped-iris for the detector improve  sensitivity across the entire mass range (demonstrated installation specification:  IDL ≤ 12 fg OFN)
  • Industry leading MRM speed at 500 transitions per second, with a minimum dwell time of 1 msec and zero cross-talk
  • A high pressure, linear collision cell with “Helium Quench Gas” to reduce neutral noise from metastable helium atoms
  • Patented hyperbolic quadrupole enhances performance up to 1050u; the unique stability of the quartz monolith allows the analyzer to be heated to 200˚C to eliminate contamination commonly seen with metal quadrupoles operated at lower temperatures
  • High-performance chromatography provided by the Agilent 7890A GC
  • Integrated Capillary Flow Technology provides reduced source maintenance, shorter analysis cycle times, and increased column lifetime
  • Small laboratory bench footprint – the mass spectrometer is only 14 inches (35 cm) wide
  • Inert ion source – programmable up to 350 ˚C – delivers enhanced response for active compounds and late eluters
  • Optional Electron Impact (EI) and Chemical Ionization (PCI and NCI) sources are available
  • Triple-Axis HED-EM Detector provides lower neutral noise
  • Differentially pumped vacuum system with a single mechanical roughing pump
  • Agilent MassHunter software, with Autotune, Batch-at-a-Glance data review, and parameter-less integrator, helps maximize productivity
  • Safe operation with hydrogen carrier gas
  • Software and Informatics
              •  
                  Partner with Agilent

                  Instrument performance and maintenance is vital to your success in the laboratory and with Agilent’s training, instrument service plans, or on-demand repair services, you will achieve reliable and accurate results with maximum instrument uptime. We understand that optimal performance is mission-critical to your productivity and you can depend on Agilent to be there when you need us. With Agilent, you can be confident that you not only have the best instrument for the job, but also the best partner for the future.

                  Relevant Links:
                  Agilent Advantage Service Plans
                  On-Demand Repair Services
                  Preventive Maintenance
                  Training & Events
                • Welcome To Agilent Technologies

                  To enhance your online experience and our partnership with you, please select your country from the lists below.This will ensure that you discover the most relevant information and services available, including local product news, events, and more.

                  Other Countries
                  Please select