400-DS Apparatus 7 
Product Description
The Agilent 400-DS Dissolution Apparatus 7 sets the performance standard for small-volume drug-release testing of medical devices such as drug eluting stents (DES). A variety of standard and custom holders are available for testing of combinatorial products, pacemaker leads, contact lenses, catheters, wound care products, extractables, leachables and more.

It is the first dissolution apparatus built specifically for small-volume dissolution testing of combination drug products that meets all compendial requirements for USP Apparatus 7. The 400-DS complies with 21 CFR Part 11 guidelines and brings an unprecedented level of convenience, throughput, and efficiency to your quality control and R&D operations.
  • Performs automated small-volume dissolution testing using as little as 3 mL media volume in either 5 or 10 mL sample cells
  • Saves time by simultaneously testing up to 13 samples, or 12 samples and a control or standard, while providing users direct visibility of each dissolution cell
  • Maintains temperature control through internal temperature probes and external heating jackets; no water bath is required
  • Minimizes evaporation through the fully closed system
  • Integrated syringe pump and autosampler save valuable bench space
  • Offers automated media addition/removal of up to 5 different types of media through a port on the bottom of the cell
  • Enables sample holder reciprocation through an externally controlled magnetic plate and supports between 1 and 35 dips per minute (DPM) to best match your requirements
  • Accommodates 12 individual sample rows with either 2 or 4 mL HPLC vials for unattended sample collection
  • Allows you to program up to 36 timepoints and five different media types into a method; software prompts for the removal and replacement of the racks during the run
  • Automates full or partial media replacement at each timepoint via a built-in fluidics module for each sample cell
  • 21 CFR Part 11 compliant software and a single PC can independently control up to four 400-DS systems
              Partner with Agilent

              Instrument performance and maintenance is vital to your success in the laboratory and with Agilent’s training, instrument service plans, or on-demand repair services, you will achieve reliable and accurate results with maximum instrument uptime. Ensure laboratory-wide productivity across your entire technology portfolio and reduce your regulatory risk with our industry-leading compliance services. We understand that optimal instrument performance is mission-critical to your operations, and you can depend on Agilent to be there when you need us. With Agilent, you can be confident that you not only have the best instrument for the job, but also the best partner for the future.

              Relevant Links:
              Agilent Advantage Service Plans
              Enterprise Edition
              On-Demand Repair Services
              Preventive Maintenance
              Training & Events

              Welcome To Agilent Technologies

              To enhance your online experience and our partnership with you, please select your country from the lists below.This will ensure that you discover the most relevant information and services available, including local product news, events, and more.

              Other Countries
              Please select