1100 Series LC and LC/MS Maintenance Videos 

white
clear clear clear clear clear

grey1
Downloads and Utilities
Education & Events
Frequently Asked Questions
DNA MicroArrays
Gas Chromatography
Lab-on-a-Chip
Life Sciences Informatics
Liquid Chromatography
Mass Spectrometry
Networked Data Systems
Proteomics
Installation and Maintenance Videos
Literature Library
Parts Information
Description, Pricing, and Availability
Illustrated Parts Breakdowns
Support Services - Finding
Warranty Status - Verifying

grey1

These innovative video clips can help you to easily perform common maintenance procedures for the Agilent's 1100 Series LC and LC/MS Modules and Systems. The videos explain each maintenance step in detail, including information about necessary tools and parts. All clips are available for download, right click on the link and choose ‘save as’).

System requirements: Windows Media Player 6.4 or above (to download the most recent version see the windows media download center) Please note: best performance for online viewing will be realized using a high-speed Internet connection (minimum 384kbs, e.g. DSL,Cable,LAN). As an alternative, you can download the video files to your hard drive first.
If you have difficulties playing the videos please contact us for help.


Currently available 1100 Series LC and LC/MS maintenance videos:

•  Isocratic Pump
•  Quaternary Pump
•  Binary Pump
•  Standard, Micro and Preparative Autosamplers
•  Well-plate Sampler and Micro Well-plate Sampler
•  Variable Wavelength Detector
•  Diode Array and Multiple Wavelength Detectors
•  Fluorescence Detector
•  LC-MSD


Isocratic Pump

Exchanging the Active Inlet Valve  - 1:56min - 3.5MB
Exchanging the Active Inlet Valve Cartridge  - 2:20min - 4.6MB
Exchanging the Outlet Ball Valve - 1:21min – 3.2 MB
Exchanging the Purge Valve Frit or the Purge Valve  - 1:27min - 3.5MB
Removing the Pump Head Assembly  - 1:43min – 4.2 MB
Exchanging the Pump Seals and Seal Wear-in Procedure - 1:05min - 2.7MB
Exchanging the Plungers  - 1:03min - 2.6MB
Reinstalling the Pump Head Assembly  - 1:45min – 4.4MB
top

Quaternary Pump

Exchanging the Active Inlet Valve  - 1:56min – 4.6MB
Exchanging the Active Inlet Valve Cartridge  - 2:20min – 5.6MB
Exchanging the Outlet Ball Valve - 1:21min – 3.2MB
Exchanging the Purge Valve Frit or the Purge Valve - 1:27min - 3.5MB
Removing the Pump Head Assembly - 1:43min – 4.2MB

Exchanging the Pump Seals and Seal Wear-in Procedure  - 1:05min - 2.7MB

Exchanging the Plungers- 1:03min - 2.6MB
Reinstalling the Pump Head Assembly - 1:45min – 4.4MB
top

Binary Pump

Exchanging the Active Inlet Valve - 1:33min - 3.6MB
Exchanging the Active Inlet Valve Cartridge - 1:55min – 4.6MB
Exchanging the Outlet Ball Valve Sieve or the Complete Valve - 2:02min – 4.4MB
Exchanging the Purge Valve Frit or the Purge Valve- 1:27min - 3.5MB
Exchanging the Solvent Selection Valve - 1:40min – 4.2MB
Removing the Pump Head Assembly- 1:57min – 4.4MB
Exchanging the Pump Seals - 1:24min – 3.4MB
Exchanging the Plungers - 0:38min - 1.6MB
Reinstalling the Pump Head Assembly - 1:44min – 4.3MB
top

Standard, Micro and Preparative Autosamplers

Needle Assembly - 2:32min – 6.2MB
Needle-Seat Assembly  - 1:37min – 4.0MB
Stator Face - 3:06min – 7.6MB
Rotor Seal - 4:03min – 10.0MB
top

Well-plate Sampler and Micro Well-plate Sampler

Removing the Needle Assembly  - 2:07min - 4.9MB
Installing the Needle Assembly  - 4:22min – 10.5MB
Removing the Needle Carrier Assembly  - 1:35min – 4.0MB
Installing the Needle Carrier Assembly  - 2:04min – 5.0MB
8A Samplers - 2:16min - 4.5MB
Stator Face - 3:13min – 7.5MB
Rotor Seal  - 3:47min – 9.1MB
Metering Seal and Plunger  - 3:36min – 8.7MB
Removing the Loop Capillary  - 3:32min - 7.1MB
Peristaltic Pump  - 1:25min - 3.5MB
top

Variable Wavelength Detector

Exchanging a Lamp - 2:05min - 4.6MB
Exchanging a Flow Cell - 1:41min – 4.1MB
Repairing the Flow Cells - 3:28min – 8.5MB
Using the Cuvette Holder - 1:23min - 3.5MB
top

Diode Array and Multiple Wavelength Detectors

Exchanging a Lamp - 1:25min – 3.4MB
Exchanging a Flow Cell - 2:02min - 4.8MB
Repairing the Standard or Semi-Micro Flow Cell - 3:00min – 7.4MB
Cleaning or Exchanging the Holmium Oxide Filter - 2:25min - 5.8MB
Cleaning or Replacing Coupling Lens Assembly - 2:32min - 6.4MB
Cleaning or Replacing Cell Support Window - 2:34min – 6.4MB
top

Fluorescence Detector

Exchanging a Flow Cell - 2:54min – 6.1MB
How to use the Cuvette - 1:13min – 3.0MB
top

LC-MSD

Opening the Analyzer - 1:25min – 3.3MB

Closing the Analyzer - 1:51min - 3.9MB

Replacing the Electron Multiplier Horn - 0:54min – 2.2MB
Cleaning the High Energy Dynode - 4:51min - 10.0MB

Checking the Foreline Pump Fluid Level - 0:41min - 1.5MB

Adding Foreline Pump Fluid - 0:50min – 2.0MB
Replacing the Foreline Pump Fluid - 1:57min - 4.7MB
Converting from Electrospray to APCI - 1:53min – 4.5MB

Converting from APCI to Electrospray - 1:59min – 4.7MB 

Cleaning the Electrospray Spray Chamber - Daily - 2:16min - 4.9MB

Cleaning the Electrospray Spray Chamber - Weekly - 3:41min – 8.6M

Replacing the Electrospray Nebulizer Needle - 6:01min – 14.8MB
Adjusting the Electrospray Nebulizer Needle - 1:34min - 3.7MB

Reinstalling the Electrospray Nebulizer - 0:55min – 2.1MB

Cleaning the APCI Spray Chamber - Daily - 2:45min – 6.1MB

Cleaning the APCI Spray Chamber - Weekly - 3:50min – 8.9MB

Replacing the APCI Nebulizer Needle - 4:43min – 11.5MB
Adjusting the APCI Nebulizer Needle - 1:37min - 3.8MB

Reinstalling the APCI Nebulizer - 0:37min - 1.4MB 

Cleaning the Corona Needle - 1:19min - 2.7MB

Replacing the Corona Needle - 1:10min - 2.7MB

Removing the Capillary - 0:47min - 1.8MB
Cleaning the Capillary - 1:55min – 4.5MB

Reinstalling the Capillary - 0:55min – 2.1MB 

Removing the Desolvation Assembly - 1:18min – 3.0MB
Cleaning Skimmer 1 - 0:34min - 1.4MB

Reinstalling the Desolvation Assembly - 1:06min - 2.8MB 

Checking Calibrant Levels - 0:24min - 0.9MB
Refilling a Calibrant Bottle - 1:25min - 2.9MB
Flushing the Calibrant Delivery System - 1:36min - 3.6MB
Checking for Leaks - 2:33min - 5.8MB
top



As always, Agilent's Technical Support Team is available to answer any questions you may have regarding installation or maintenance of Agilent products.