  • What is the Capacity Difference Between Multiple Affinity Removal LC Columns and Spin Cartridge?
      4.6 x 50 mm (5185-5984) human serum LC column capacity: Protein mass: 1.2 – 1.6 mg total serum proteins. Serum volume: 15 – 20 µL human serum. 4.6 x 100 mm (5185-5985) human serum LC column capacity: Protein mass: 2.4 – 3.2 mg total serum proteins. Serum volume: 30 – 40 µL human serum. 4.6 x 50 mm (5188-5217) mouse serum LC column capacity: Serum volume: 37 – 50 µL mouse serum (determined with Swiss Webster mouse serum; 40% less for rat serum). Mouse and rat serum protein concentrations can vary with strain, sample sizes should be adjusted accordingly. 4.6 x 100 mm (5188-5218) mouse serum LC column capacity: Serum volume: 75 – 100 µL mouse serum (determined with Swiss Webster mouse serum; 40% less for rat serum). Mouse and rat serum protein concentrations can vary with strain, sample sizes should be adjusted accordingly. 10 x 100 mm (5188-5336) ) human 6-high capacity serum LC column capacity: Protein mass: 21.0 - 28 mg total serum proteins. Serum volume: up to 350 µL human serum. 4.6 x 50 mm (5188-6409) human 7 plasma LC column capacity: Protein mass: 2.1 - 2.8 mg total serum proteins. Serum volume: 30 - 35 µL human serum. 4.6 x 100 mm (5188-6410) human 7 plasma LC column capacity: Protein mass: 4.2 - 5.6 mg total serum proteins. Serum volume: 60 - 70 µL human serum 10 x 100 mm (5188-6411) human 7 plasma LC column capacity: Protein mass: 18 - 24 mg total serum proteins. Serum volume: 250 - 300 µL human serum 0.45 mL (5188-5230) human 6 serum spin cartridge capacity: Serum volume: 7 - 10 µL human serum. 0.45 mL (5188-5341) human 6-high capacity serum spin cartridge capacity: Serum volume: 14 - 16 µL human serum. 0.45 mL (5188-6408) human 7 plasma spin cartridge capacity: Serum volume: 12 - 14 µL human serum. 4.6 x 50 mm (5188-5217) mouse serum LC column capacity: Serum volume: 37 - 50 µL mouse serum (determined with Swiss Webster mouse serum; 40% less for rat serum). Mouse and rat serum protein concentrations can vary with strain, sample sizes should be adjusted accordingly. 4.6 x 100 mm (5188-5218) mouse serum LC column capacity: Serum volume: 75 - 100 µL mouse serum (determined with Swiss Webster mouse serum; 40% less for rat serum). Mouse and rat serum protein concentrations can vary with strain, sample sizes should be adjusted accordingly. 0.45 mL (5188-5289) mouse serum spin cartridge capacity: Serum volume: 25 - 30 µL mouse serum (determined with Swiss Webster mouse serum; 40% less for rat serum). Mouse and rat serum protein concentrations can vary with strain, sample sizes should be adjusted accordingly. Note: Consult the LC column or spin cartridge certificate of analysis (included with product) to determine the capacity of the device.