Agilent Technologies LSCA - Our measure is your success
clear
white
clear
white
clear

MSD Productivity ChemStation 

white
clear clear clear clear clear

grey1
Downloads and Utilities
Education & Events
Frequently Asked Questions
DNA MicroArrays
Gas Chromatography
Lab-on-a-Chip
Life Sciences Informatics
Liquid Chromatography
Mass Spectrometry
Networked Data Systems
Proteomics
Installation and Maintenance Videos
Literature Library
Parts Information
Description, Pricing, and Availability
Illustrated Parts Breakdowns
Support Services - Finding
Warranty Status - Verifying

grey1

Agilent MSD Productivity ChemStation Software: Unless otherwise noted, Software revisions also include defect fixes and / or enhancements. Consult Software Status Bulletins (SSB) for more specific information on Release versions.

Hardware Compatibility chart can be found below the MS ChemStations table.

MSD Productivity ChemStation

Revision

Product

What's New

Localization

Operating System (Prof.)

Min. PC/

Printer

E.02.00 SP2

05/09

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

7890A GC driver update and point patches from E.02.00/SP1

7693 Support

Chinese

Win XP SP2

Win Vista

1 Ghertz 

1 Gbyte

(2GByte recommended)

Japanese

English

E.02.00 SP1

10/08

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

7890A GC driver update and point patches from E.02.00

Chinese

Win XP SP2

Win Vista

1 Ghertz 

1 Gbyte

(2GByte recommended)

Japanese

Win XP SP2

Win Vista

English

Win XP SP2

Win Vista

E.02.00

2/26/08

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

7890A GC

Chinese

Win XP SP2

Win Vista

1 Ghertz 

1 Gbyte

(2GByte recommended)

Japanese

Win XP SP2

Win Vista

English

Win XP SP2

Win Vista

E.01.00 P02

11/13/07

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

7890A GC

Chinese

Win XP SP2

1 Ghertz 

512 Mbyte

(1GByte recommended)

Japanese

Win XP SP2

English

Win XP SP2

E.01.00 P01

6/25/07

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

7890A GC

Chinese

Win XP SP2

1 Ghertz 

512 Mbyte

(1GByte recommended)

Japanese

Win XP SP2

English

Win XP SP2

E.01.00

5/25/07

 

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

7890A GC

Chinese

 

Win XP SP2

1 Ghertz 

512 Mbyte

(1GByte recommended)

Japanese

 

Win XP SP2

English

Win XP SP2

E.00.00

4/17/07

 

G1701EA

G1710EA

G1711EA

G1617EA

G1618EA

5975C

 

Chinese

Not Supported

1 Ghertz 

512 Mbyte

(1GByte recommended)

Japanese

Not Supported

English

Win XP SP2

D.03.00 SP2

11/30/07

 

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

Point Patches Updates

Chinese

Win XP SP2*

*or higher

 

          

1 Ghertz  256Mb

(512 Mbyte mini. Req.)

Japanese

Win XP SP2*

*or higher

English

Win XP SP2*

Win2KSP4 *

Year 2000

*or higher

D.03.00 SP1

9/27/06

 

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

CTC PAL support

Chinese

Win XP SP2*

*or higher

1 Ghertz  256Mb

(512 Mbyte mini. Req.)

Japanese

Win XP SP2*

*or higher

English

Win XP SP2*

Win2KSP4 *

Year 2000

*or higher

D.03.00

7/13/06

 

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

EasyICs

5975B Support

Chinese

Win XP SP2*

*or higher

1 Ghertz  256Mb

(512 Mbyte mini. Req.)

Japanese

Win XP SP2*

*or higher

English

Win XP SP2*

Win2KSP4 *

Year 2000

*or higher

D.02.00 SP1

8/1/05

 

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

Japanese and Chinese was merged

Chinese

Win XP SP2*

*or higher

1 Ghertz  256Mb

(512 Mbyte mini. Req.)

Japanese

Win XP SP2*

*or higher

English

Win XP SP2*

Win2KSP4 *

Year 2000

*or higher

D.02.00

6/1/05

 

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

Unifield Instrument Control; 5975 Support

 

Win XP SP2*

Win2KSP4 *

Year 2000

*or higher

1 Ghertz  256Mb

(512 Mbyte mini. Req.)

D.01.00 SP2

7/1/04

(D.01.02)

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

Updates/Patches to D.01.01, Fast Electronics Support

 

Win XP SP1*

Win2KSP2 *

Year 2000

*or higher

P3 -- 900 Mhertz  128Mb

 

D.01.00 SP1

11/1/03

(D.01.01)

G1701DA

G1710DA

G1711DA

G1617DA

G1618DA

Updates/Patches to D.01.00, SC3+ support

 

Win XP SP1*

Win2KSP2 *

Year 2000

*or higher

P3 -- 900 Mhertz  128Mb

 

D.01.00

09/8/03

 

G1701DA

G1710DA

G1711DA

G1617DA

ToolBar Icons, Long File Names, support for GPIB added

 

Win XP SP1*

Win2KSP2 *

Year 2000

*or higher

P3 -- 900 Mhertz  128Mb

 

D.00.01

12/1/02

 

G1701DA

G1710DA

G1711DA

G1617DA

Updates to DrugQuant

 

WinNT4.0SP6a

Win2KSP2

Year 2000

P3 -- 900 Mhertz  128Mb

LJ4000

D.00.00

11/1/01

 

G1701DA

G1710DA

G1711DA

G1617DA

Patches from CA

AutoSim Setup

Integrated IQ Seq

 

WinNT4.0SP6a

Win2KSP2

Year 2000

P3 -- 900 Mhertz  128Mb

LJ4000

C.00.01

01/12/01

G1701CA

G1710CA

G1711CA

G1617CA

C.00.00 plus all patches

 

Win NT 4.0

SP 6.0a

Year 2000

Pentium 266 mhz.  64Mb,  LJ4000, 6P

C.00.00

12/1/99

G1701CA

G1710CA

G1711CA

G1617CA

LAN

DQ Int Seq.

Closed RTL,  Validation.

 

Win NT 4.0

SP 4.0

Year 2000

Pentium 266 mhz.  64Mb,  LJ4000, 6P

B.02.00

9/1/00

G1701BA

G1710BA

G1711BA

G1617AA

B.01. plus: all patches

 

Win NT 4.0

SP 6a

Pentium 120 mhz.  48Mb,  LJ4000, 6P

B.01.00

8/15/98

G1701BA

G1710BA

G1711BA

G1617AA

B.00.01 plus: RTL, Y2K Certified, real time plot.

 

Win NT 4.0

Carries HP Year 2000.

Pentium 120 mhz.  48Mb,  LJ4000, 6P

B.00.01

M3.8

11/1/97

G1701BA

G1710BA

G1617AA

5973CI, Drug Analysis mode, Custom Reports with Graphics

 

Win NT 4.0

Carries HP Year 2000.

Pentium 120 mhz.  48Mb, LJ5,5/6L

A.03.00

M3.75

8/15/96

G1701AA

G1625A

G1710AA

5973 Support

Enhanced DA

GC DA

 

Win 95

Pentium 24M

LJ5, 5L

A.02.00

M3.72

4/96

G1701AA

G1625A

35900A/D Suppt

Win 95 Support

 

Win 95

WFW 3.11

DOS 6.2

Pentium 24M

LJ5, 5L, 4+

A.01.00

M3.71

12/95

G1701AA

G1625A

G1032C Compt.

5890 Support

 

WFW 3.11

DOS 6.2

Pentium 16M

LJ4+,  DeskJet

A.00.00

M3.65

7/95

G1701AA

6890 Support

Instrument Cntrl

GC Acquisition

 

WFW 3.11

DOS 6.2

486   16M

LJ4, DeskJet

C.03.04

M3.65

G1034C

G1620A

LCMS Support

 

Win3.1/.11

DOS 6.2

Excel 5

486   8M

LJ4, DeskJet

C.02.03

G1034C

G1620A

5989B Support

Excel 5.0

 

Win3.1

DOS 6

Excel 4

386

4M

C.01.05

G1034C

G1620A

5972 Support

Chem Structures

 

Win3.1

DOS5/Excl4

386

4M

C.00.07

G1034C

Macro Change

 

 

Win3.0

DOS5/ Excl4

386

4M

 

Hardware Compatibility

Revision

MS

Smart Card

GC/Acces.

ALS

Detectors

35900A/D

LAN/HPIB

Media

E.02.00 SP2
05/09

5975A
5975B
5975C
5975C TAD
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+

6890N
6890
6890+
6850
7890A

7683
7673
7693* (7890)
 
 
 
* No Sample Prep

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

IO Lib Vrs 15
BootP Service

CD

E.02.00 SP1
10/08

5975A
5975B
5975C
5975C TAD
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+

6890N
6890
6890+
6850
7890A

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

IO Lib Vrs 15
BootP Service

CD

E.02.00
2/26/08

5975A
5975B
5975C
5975C TAD
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+

6890N
6890
6890+
6850
7890A

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

IO Lib Vrs 15
BootP Service

CD

E.01.00 P02
11/13/07

5975A
5975B
5975C
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+

6890N
6890
6890+
6850
7890A

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
BootP Service

CD

E.01.00 P01
6/25/07

5975A
5975B
5975C
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+

6890N
6890
6890+
6850
7890A

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
BootP Service

CD

E.01.00
5/25/07
 

5975A
5975B
5975C
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+

6890N
6890
6890+
6850
7890A

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
BootP Service

CD

E.00.00
4/17/07
 

5975A
5975B
5975C
5973 Inert/*
5973N/*
 
* Fast Elect.

SCIII+
SCIII+
SCIII+
SCIII,III+
SCIII,III+
 

6890N
6890
6890+
6850
 
 

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
BootP Service

CD

D.03.00 SP2
11/30/07
 

5975A
5975B
5973 Inert/*
5973N/*
5973A
 
* Fast Elect.

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+
6850

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
SICL GPIB–M01.01
BootP Service

CD

D.03.00 SP1
9/27/06
 

5975A
5975B
5973 Inert/*
5973N/*
5973A
 
* Fast Elect.

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+
6850

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
SICL GPIB–M01.01
BootP Service

CD

D.03.00
7/13/06
 

5975A
5975B
5973 Inert/*
5973N/*
5973A
 
* Fast Elect.

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+
6850

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
SICL GPIB–M01.01
BootP Service

CD

D.02.00 SP1
8/1/05

5975 Inert
5973 Inert/*
5973N/*
5973A
* Fast Elect.

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+
6850

7683
7673

FID, TCD, NPD, ECD, uECD,  Single Wav FPD, DFPD

None

SICL LAN– M01.01
SICL GPIB–M01.01
BootP Service

CD

D.02.00  
6/1/05

5975
5973 Inert/*
5973N/*
5973A
* Fast Elect.

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+
6850

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single and dual wavelength)

None

SICL LAN– M01.01
SICL GPIB–M01.01
BootP Service

CD

D.01.00 SP2
7/1/04
(D.01.02)

5973 Inert/*
5973N/*
5973A
* Fast Elect.

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

SICL LAN– M01.01
SICL GPIB–M01.01
BootP Service

CD

D.01.00 SP1
11/1/03
(D.01.01)

5973 Inert
5973N
5973A

SCIII,III+
SCIII,III+
SCII+

6890N
6890
6890+

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

SICL LAN–L02.01
SICL GPIB–M01.01
BootP Service

CD

D.01.00
09/8/03
 

5973 Inert
5973N
5973A

SCIII
SCIII
SCII+

6890N
6890
6890+

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

SICL LAN–L02.01
SICL GPIB–M01.01
BootP Service

CD

D.00.01
12/1/02
 

5973N
5973A(LAN)

SCIII

6890N
6890(LAN)
6890+(LAN)

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

LAN
SICL J.02.00
BootP Ver 1.2

CD

D.00.00
11/1/01
 

5973N
5973A(LAN)

SCIII

6890N
6890(LAN)
6890+(LAN)

7683
7673

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

LAN
SICL J.02.00
BootP Ver 1.2

CD

C.00.01
01/12/01

5973N
[5973A
5972A original PC hardware
]

SCIII

6890, 6890+,  
P/T (2)
HS (2)

18594B G1512A
G2612A

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

LAN  
SICL H.01.02
[82341C
SICL G.02.02]

CD

C.00.00
12/1/99

5973N
5973, 5972, 

SCIII
SCII+
SCII

6890, 6890+,  
P/T (2)
HS (2)

18594B G1512A
G2612A

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

None

LAN  
SICL G.02.02
82341C
SICL G.02.02

CD

B.02.00
9/1/00

5973, 5972,  G1800C

SCII+
SCII
SCII+

6890, 6890+, 5890II/II+
P/T (2)
HS (2)

18594B G1512A
G2612A

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

35900C/E

82350A
SICL H.01.02
 
82341C
SICL F.01.02

CD

B.01.00
8/15/98

5973, 5972,  G1800C

SCII+
SCII
SCII+

6890, 6890+, 5890II/II+
P/T (2)
HS (2)

18594B G1512A
G2612A

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

35900C/E

82341C
SICL F.01.02

CD

B.00.01
M3.8
11/1/97

5973, 5972,  G1800C

SCII+  
SCII
SCII+

6890, 6890+, 5890II/II+
P/T (2)
HS (2)

18594B G1512A
G2612A

FID, TCD, NPD, ECD, micro-ECD, FPD (single wavelength only)

35900C/E

82341C
SICL F.01.02

CD

A.03.00
M3.75
8/15/96

5973
5972
5971
5970

SCII+
SCII
SCII
SCII+ only

6890
6890/5890II
5890II/I
5890II/I

18594B
G1512A

FID, TCD, ECD

35900C/D/E

82335
82341C
SICL D.02.00,  
F.01.02 

CD

A.02.00
M3.72
4/96

5972
5971
5970

SCII
SCII
SCII + only

6890/ 5890II
5890II/I
5890II/I

18594B
G1512A

No GC Detectors

35900C/D/E

82335
 

CD

A.01.00
M3.71
12/95

5972
5971
5970

SCII
SCII
SCII + only

6890/ 5890II
5890II/I
5890II/I

18594B  
G1512A

No GC Detectors

 

82335

CD  
3.5(1)

A.00.00
M3.65
7/95

5972
opt #689

SCII

6890
 

G1512A

No GC Detectors

 

82335

CD
3.5(1)

C.03.04
M3.65

5989B  
5972  
5971/70

SCII
SCII
SCI

5890
 

 

 

 

82335

CD
3.5

C.02.03

5989B
5972
5971/70

SCII
SCII
SCI

5890

 

 

 

82335

3.5
5.25

C.01.05

5989A(3)
5972
5971/70

SCI
SCII
SCI

5890

 

 

 

82335

3.5
5.25

C.00.07

5989A
5971/70

SCI
SCI

5890

 

 

 

82335

5.25


(1) Replacement media.    (2) Support via contact closure.

For additional information on MSD Productivity ChemStation, click here.
 

grey1
related_bottom_left clear clear clear
clear clear
grey2
Please select your country:
 
   
Registration   |  Login Benefits of Registration