Agilent Life Sciences and Chemical Analysis Software Patches Download Area
The following software patches are available for download. Click on the patch you wish to download. At this point your browser will probably ask you what it should do with the file. Select "Save File" or similar option and download the patch to an empty subdirectory on your hard disk. For ZIP archives you will need PKUNZIP or similar utility to expand the ZIP file. Once the archive is expanded, follow the directions in the readme file.
Note: Only apply a patch to the particular revision of the Agilent software product for which it was intended. Applying patches to the incorrect revision of Agilent software may result in corruption of your application software and your data.
The Service Pack SP3 fixes the following defects in the Qualitative Analysis rev. B.03.01 software:
1. (#17738) Peak Filters in MS/MS Spectral Library search must apply to centroid data
2. (#18459) Find by formula numbers compounds in different order than what user had specified
3. (#18633) MFE not finding compounds
4. (#18713) MFE compounds are not delaytime adjusted
5. (#18739) Null reference exception when generating report for library search result
6. (#18498) Spectra with MFG results are displayed in spectrum result window though uncheck from the Data Navigator.
7. (#17949) Compound Summary Report reports header for each sample
8. (#18770) Customer reported problems for MFE
9. (#18747) Manual integration gives incorrect results
10. (#18119) Recalibration window: in order to use it next time start Qual, has to be closed before Qual is closed.
11. (#18300) MFE -> extract EIC sometimes results in exception
12. (#17779) Abund Match and Spacing Match do not get populated after Find By Formula and Identify Compounds by Searching the Database.
13. (#18768) Error while generating report with BioMatch hits
14. (#18773) Universal Integrator Shows 10x More Area than Other Integrator
15. (#18799) TOF ASR generation [MASSES] section Observed Mass is incorrect
16. (#18846) Problem with MSMS Library Structure In Plot
17. (#18906) CEF file export issue: same method via Qual UI vs. Qual automation (each export to CEF) produces different results.
18. (#18921) Resolved Isotope Deconvolution is not available via worklist actions
19. (#18910) .CEF file export needs to normalize Chromatogram Deconvolution peaks to 1000 base peak height
20. (#18914) .CEF export for GC/MS chromatogram deconvolution features needs to round down m/z to unit mass
21. (#18920) MFG crashes on data containing selenium compounds
22. (#18927) Hi-res support for BioConfirm
23. Newly Localized Online Help text file available
24. Updated localized dlls
Installation instructions are in the Service Note G3335AA MASSHUNTER SOFTWARE-63.