Qualitative Analysis rev. B.02.00 Service Pack 3 (SP3) 

white
clear clear clear clear clear

grey1
Downloads and Utilities
Education & Events
Frequently Asked Questions
DNA MicroArrays
Gas Chromatography
Lab-on-a-Chip
Life Sciences Informatics
Liquid Chromatography
Mass Spectrometry
Networked Data Systems
Proteomics
Installation and Maintenance Videos
Literature Library
Parts Information
Description, Pricing, and Availability
Illustrated Parts Breakdowns
Support Services - Finding
Warranty Status - Verifying

grey1

Agilent Life Sciences and Chemical Analysis Software Patches Download Area


The following software patches are available for download. Click on the patch you wish to download. At this point your browser will probably ask you what it should do with the file. Select "Save File" or similar option and download the patch to an empty subdirectory on your hard disk. For ZIP archives you will need PKUNZIP or similar utility to expand the ZIP file. Once the archive is expanded, follow the directions in the readme file.

Note: Only apply a patch to the particular revision of the Agilent software product for which it was intended. Applying patches to the incorrect revision of Agilent software may result in corruption of your application software and your data.


The Service Pack SP3 fixes the following defects in the Qualitative Analysis rev. B.02.00 software:

1.      (#03737) Plot window report not working when in Overlaid mode

2.      (#03747) Acquisition method report from Qual causes tune report to fail

3.      (#03760) Database search ignores Identity Scoring parameters

4.      (#03753) DRM chromatogram looks zig-zag

5.      (#03762) Compound Automation without Report does not create correct info.xml file

6.      (#03765) Error when ChemStation integrator used for targeted MS/MS

7.      (#03748) Error when trying to calculate system suitability values

8.      (#13310) Qual: MFE crash if run with advanced parameter "include w/o neutral mass"

9.      (#13360) Exception when doing formula generation on MFE compound with species of ""M+?"

10.     (#13387) Crash of compound database search (MFE creates bad spectrum)

11.     (#13490) Time ranges do not apply to ChemStation integrator

12.     (#3758) A4 report templates were not used

13.     (#13381,#13382,#13368,#13507) Various specific formulas cannot be found with MFG or the formula calculator

14.     (#15775) Export to MzData that requires profile->centroid conversion is too slow

15.     (#13671) Qual Extracts Chromatograms for transitions not asked for: Dynamic MRM

16.     (#15939) Exception when loading multi-digest-sequence-matched result data

17.     (#15949) Formula calculator does not honor [nnXx] syntax when Xx is not "H" or "C"

18.     (#16020) Find by Formula with MS/MS integrator does not honor EIC Peak Filters

19.     (#16133) TOF MS peak areas are needed for MALDI users

In addition, it adds the following enhancements to the G6829AA MassHunter BioConfirm Software rev. B.02.00:

1. Predicted modification - replace the "protein modification" and "sample handling artifacts" matching rules with "predicted modification"
for protein and protein digest sequence types.  User can specify a list of predicted modifications for sequence matching.

2. Variable modification - support site specific variable modification for protein and peptide sequences

3. Oligonucleotide - allow you to create oligonucleotide sequences and do sequence matching for oligonucleotides.

Installation instructions are in the Service Note G3335AA MASSHUNTER SOFTWARE-35A.