Agilent Life Sciences and Chemical Analysis Software Patches Download Area
The following software patches are available for download. Click on the patch you wish to download. At this point your browser will probably ask you what it should do with the file. Select "Save File" or similar option and download the patch to an empty subdirectory on your hard disk. For ZIP archives you will need PKUNZIP or similar utility to expand the ZIP file. Once the archive is expanded, follow the directions in the readme file.
Note: Only apply a patch to the particular revision of the Agilent software product for which it was intended. Applying patches to the incorrect revision of Agilent software may result in corruption of your application software and your data.
Service Pack 2 for MassHunter Acquisition for QQQ rev. B.02.01 is cumulative and includes the following:
Support LC 1260 devices
- Additional syringe volume choices for 4226A
- Needle Seat Back Flush using G4227A Flexible Cube is supported.
- The Carryover Reduction feature for the 1260 Chip Cube is supported.
- The Agilent 1260 Isocratic Pump (G1310B) is supported.
- The Agilent 1260 Quaternary Pump (G1311B) is supported.
- The Agilent 1260 Quaternary Pump VL (G1311C) is supported.
- The Agilent 1260 Capillary Pump (G1376A) is supported.
- The Agilent 1260 Nano Pump (G2226A) is supported.
- The Agilent 1260 Binary Pump (G1312B) is supported.
- The Agilent 1260 Binary Pump VL (G1312C) is supported.
- The Agilent 1290 Binary Pump VL (G4220B) is supported.
- The Agilent 1260 Standard Autosampler (G1329B) is supported.
- The Agilent 1260 High Performance Autosampler (G1367E) is supported.
- The Agilent 1260 Micro High Performance Autosampler (G1377A) is supported.
- The Agilent 1290 LC Injector HTC/HTS (G4277A) is supported.
- The Agilent 1290 LC Injector HTC/HTS (G4278A) is supported.
- The Agilent 1260 Variable Wavelength Detector VL (G1314B) is supported.
- The Agilent 1260 Variable Wavelength Detector SL (G1314C) is supported.
- The Agilent 1260 Variable Wavelength Detector (G1314F) is supported.
- The Agilent 1290 Variable Wavelength Detector (G1314E) is supported.
- The Agilent 1260 Diode Array Detector SL (G1315C) is supported.
- The Agilent 1260 Diode Array Detector VL (G1315D) is supported.
- The Agilent 1260 Diode Array Detector (G4212B) is supported.
- The Agilent 1260 TCC (Thermostatted Column Compartment) (G1316A) is supported.
B.03.01 SP2 Defects Fixes:
- Ejecting ChipCube and loading method later causes timetable resets on Operate.
- The "position name" information does not getting saved into method file.
- Valve method become dirty when no change is made.
- Chip valve combo box contents can be deleted
- 1290 DAD mAU Scaling is Different from ChemStation and LabAdvisor.
- 6 Port CAN Valve in B.03.01 Behaves Differently from B.02.01 or B.02.01 SP
- UV Spectrum Data Retention time
- External Valves Prevent Method/Worklist Editor from Starting (Picard Core)
PLEASE NOTE:
Service Pack 2 should only be applied to 6538/6540 UHD Q-TOF systems. It is not intended for any 6500 Series Q-TOF LC/MS systems.
NOTE: All MassHunter processes must be stopped before applying the SP2 because it updates the device driver files.