QuEChERS Dispersive SPE Kits 

white
clear clear clear clear clear

grey1
Literature Library
Technical Support
Education & Events

grey1

Step Two: Dispersive SPE Clean-Up

Select the Dispersive SPE kit suited to the type of food being analyzed and the method you are following. In this step, an aliquot of the sample extract from Step One is added to 2 mL or 15 mL centrifuge tube containing a small amount of SPE sorbent and MgSO4. The sorbent will pull out intefering matrix materials from the sample, and the MgSO4 helps remove excess water and improve analyte partitioning

 Suggested Dispersive Kits by Food Type and Method

Dispersive SPE Kits
Kit Quantity & Size/Pack AOAC 2007.01 Method European Method EN 15662
Contents & Part No.
CH - with Ceramic Homogenizers
Contents & Part No.
CH - with Ceramic Homogenizers
General Fruits and Vegetables:
Removes polar organic acids, some sugars and lipids
100 – 2 mL tubes 50 mg PSA
150 mg MgSO4
Part No. 5982-5022, 5982-5022CH
25 mg PSA
150 mg MgSO4
Part No. 5982-5021, 5982-5021CH
50 – 15 mL tubes 400 mg PSA
1200 mg MgSO4
Part No. 5982-5058, 5982-5058CH
150 mg PSA
900 mg MgSO4
Part No. 5982-5056,5982-5056CH
Fruits and Vegetables with Fats and Waxes:
Removes polar organic acids, some sugars, more lipids and sterols
100 – 2 mL tubes 50 mg PSA
50 mg C18EC
150 mg MgSO4
Part No. 5982-5122, 5982-5122CH
25 mg PSA
25 mg C18EC
150 mg MgSO4
Part No. 5982-5121, 5982-5121CH
50 – 15 mL tubes 400 mg PSA
400 mg C18EC
1200 mg MgSO4
Part No. 5982-5158, 5982-5158CH
150 mg PSA
150 mg C18EC
900 mg MgSO4
Part No. 5982-5156, 5982-5156CH
Pigmented Fruits and Vegetables:
Removes polar organic acids, some sugars and lipids, and carotinoides and chlorophyll; not for use with planar pesticides
100 – 2 mL tubes 50 mg PSA
50 mg GCB
150 mg MgSO4
Part No. 5982-5222, 5982-5222CH
25 mg PSA
2.5 mg GCB
150 mg MgSO4
Part No. 5982-5221, 5982-5221CH
50 – 15 mL tubes 400 mg PSA
400 mg GCB
1200 mg MgSO4
Part No. 5982-5258
150 mg PSA
15 mg GCB
885 mg MgSO4
Part No. 5982-5256, 5982-5256CH
Highly Pigmented Fruits and Vegetables:
Removes polar organic acids, some sugars and lipids, plus high levels of carotinoides and chlorophyll; not for use with planar pesticides
100 – 2 mL tubes 25 mg PSA
7.5 mg GCB
150 mg MgSO4
Part No. 5982-5321, 5982-5321CH
50 – 15 mL tubes 150 mg PSA
45 mg GCB
855 mg MgSO4
Part No. 5982-5356, 5982-5356CH
Fruits and Vegetables with Pigments and Fats:
Removes polar organic acids, some sugars and lipids, plus carotinoides and chlorophyll; not for use with planar pesticides
100 – 2 mL tubes 50 mg PSA
50 mg GCB
150 mg MgSO4
50 mg C18EC
Part No. 5982-5421
5982-5421CH
50 – 15 mL tubes 400 mg PSA
400 mg GCB
1200 mg MgSO4
400 mg C18EC
Part No. 5982-5456
5982-5456CH
Other Food Methods:
Removes biological matrix interferences,
including hydrophobic substances
(fats, lipids) and proteins
100 – 2 mL tubes 25 mg C18
150 mg MgSO4
Part No. 5982-4921
5982-4921CH
50 – 15 mL tubes 150 mg C18
900 mg MgSO4
Part No. 5982-4956
5982-4956CH
PSA = Primary Secondary Amine; GCB = Graphitized Carbon Black; C18EC = Octadecysilane, end-capped (For this step, the AOAC method specifies 1 mL or 6 mL aliquot samples; the EN method recommends 1 mL or 8 mL aliquot samples. Kits are assembled based on these specifications).
Dispersive SPE Kits
Kit Quantity & Size/Pack Contents & Part No.
CH - with Ceramic Homogenizers
Universal kits for fruits and vegetables:
Removes virtually all matrix interfering materials including: polar organic acids, lipids, sugars, proteins, carotinoids and chlorophyll.
100- 2ml 50 mg PSA
50 mg C18
7.5 mg GCB
150 mg MgSO4
Part no. 5982-0028
5982-0028CH
Universal kits for fruits and vegetables:
Removes virtually all matrix interfering materials including: polar organic acids, lipids, sugars, proteins, carotinoids and chlorophyll.
50/bx 400mg PSA
400mgC18
45mgGCB
1200mg MgSO4
Part no. 5982-0029
5982-0029CH

Agilent now offers custom QuEChERS dispersive kits to meet your specific needs. Complete this form for a custom quote. QuEChERS Kit Brochure

 
 