LC/MS System Compatibility
In general, most Agilent LC/MS ion sources work with most Agilent LC/MS instruments. However, there are some combinations of ionization technique and mass spectrometer that have little analytical utility. There are also some combinations that, for physical or software reasons, are not supported.
Compatibility of Agilent ion sources and LC/MS systems
|
|
Mass Spectrometer |
|
Ion Source |
6100 Series Quadrupole |
6200 Series TOF |
6300 Series Ion Trap |
6400 Series Triple Quad |
6500 Series Q-TOF |
|
Electrospray (ESI) |
X |
X1 |
X |
X |
X1 |
|
Atmospheric pressure chemical ionization (APCI) |
X |
X2 |
X |
X |
X2 |
|
Multimode source |
X |
X2 |
X |
X |
X2 |
|
HPLC-Chip nanoelectrospray |
X |
X2 |
X |
X |
X2 |
|
Atmospheric pressure photoionization (APPI) |
X |
X2 |
X |
X |
X2 |
|
1 -Dual nebulizer version available for TOF and Q-TOF instruments 2 -Requires reference mass solution to be introduced into the LC eluent for maximum mass accuracy |
Your Agilent sales representative or service representative can provide more specific information about compatibility between your specific model of mass spectrometer and the various Agilent ion sources. Contact an Agilent representative.
Application of Ionization Techniques
No ionization technique is suitable for all applications. Agilent offers you a wide range of choices. The Agilent ion sources are described in more detail in the following table, which provides some general compatibility guidelines. These are only general guidelines; your Agilent customer team can help you choose the best solution for your specific applications and samples. Contact an Agilent representative.
View by:
Significant Compound Classes l Functional Groups l Chemical/Physical Properties l LC Solvents l LC Flow Rate
General guidelines for applicability of ionization techniques
|
excellent |
= best match with highest chance of success |
|
good |
= generally works well or can be made to work with minor method adjustments |
|
limited |
= unlikely to provide best results, but may work for some samples or with significant method adjustments |
|
poor |
= poor match with little chance of success, or not applicable |
|
|
Ionization Technique |
|
|
Electrospray |
APCI |
Multimode |
APPI |
|
Significant Compound Classes |
|
DNA |
good |
poor |
good |
poor |
|
Proteins |
excellent |
poor |
good |
poor |
|
Peptides |
excellent |
poor |
good |
poor |
|
Amino Acids |
good |
limited |
good |
limited |
|
Polymers |
good |
limited |
good |
poor |
|
Carbohydrates |
good |
excellent |
excellent |
excellent |
|
Triglycerides |
limited |
excellent |
excellent |
excellent |
|
Aromatic hydrocarbons |
poor |
limited |
limited |
excellent |
|
Aliphatic hydrocarbons |
poor |
limited |
limited |
good |
|
|
Electrospray |
APCI |
Multimode |
APPI |
|
Functional Groups |
|
Acids |
excellent |
good |
excellent |
good |
|
Alcohols |
limited |
good |
good |
good |
|
Aldehydes and Ketones |
limited |
good |
good |
good |
|
Alkanes |
poor |
limited |
limited |
good |
|
Alkynes |
poor |
good |
good |
excellent |
|
Amines |
excellent |
excellent |
excellent |
excellent |
|
Carbonyls |
limited |
good |
good |
good |
|
Esters |
good |
excellent |
excellent |
excellent |
|
Ethers |
limited |
good |
good |
good |
|
Phenols |
good |
excellent |
excellent |
excellent |
|
|
Electrospray |
APCI |
Multimode |
APPI |
|
Chemical/Physical Properties |
|
Polar |
excellent |
good |
excellent |
good |
|
Non-polar |
poor |
good |
good |
excellent |
|
Volatile |
excellent |
excellent |
excellent |
excellent |
|
Non-volatile |
excellent |
poor |
excellent |
poor |
|
Thermally stable |
excellent |
excellent |
excellent |
excellent |
|
Thermally unstable |
excellent |
poor |
limited |
poor |
|
Susceptible to ion suppression |
poor |
good |
good |
good |
|
|
Electrospray |
APCI |
Multimode |
APPI |
|
LC Solvents |
|
Polar solvents |
excellent |
excellent |
excellent |
excellent |
|
Non-polar solvents |
poor |
excellent |
excellent |
excellent |
|
Salts and buffers |
limited |
good |
good |
good |
|
Ion pairing agents |
limited |
good |
good |
limited |
|
Volatile modifiers |
excellent |
excellent |
excellent |
excellent |
|
|
Electrospray |
APCI |
Multimode |
APPI |
|
LC Flow Rate |
|
Greater than 1 mL/min |
limited |
excellent |
excellent |
excellent |
|
500 – 1000 µL/min |
good |
excellent |
excellent |
excellent |
|
100 – 500 µL/min |
excellent |
good |
excellent |
good |
|
1 – 100 µL/min |
excellent |
limited |
good |
limited |
|
Less than 1 µL/min |
excellent |
poor |
poor |
poor |
|