State of the art performance - 6300 Series Ion Trap LC/MS Systems 

white
clear clear clear clear clear

grey1
Literature Library
Technical Support
Education & Events

grey1
The Agilent 6300 Series Ion Trap LC/MS systems combine exceptional performance with versatility and reliability. There is a performance level to match every need and budget.

Unsurpassed sensitivity

Each of the 6300 Series ion traps offers a different performance level. You pay for only the performance you need.

Sensitivity
6310 6320 6330 6340
Quantity (reserpine) 5 pg 1 pg 250 fg TBD*
Signal-to-Noise Ratio (full scan MS/MS) 25:1 50:1 50:1 TBD*
* To be determined

Even greater sensitivity can be achieve with the lower-flow capillary and orthogonal nanoESI sources and the PDF-MALDI ion source. Click here for more information about ion source alternatives.

Superior combinations of mass accuracy, mass resolution, and scan speed

Thanks to patented multipole, non-linear ion trap technology, the 6300 Series ion traps offer superior combinations of mass range, mass resolution, and scan speed.

Mass range, mass resolution, and scan speed
6310 6320, 6330, & 6340
Mass Range
m/z
Resolution
FWHM (u)
Scan Speed
(u/s)
Resolution
FWHM (u)
Scan Speed*
(u/s)
50 - 2200 0.6 13,000 0.6 26,000
0.45 5,500 0.35 8,100
0.35 1,650 0.25 800
200 - 4000 3 - 4 27,000 3 27,000

*Total scan cycle times for the 6330 and 6340 are approximately 1/3 the scan cycle time of the 6320, allowing the 6330 and 6340 to perform 3X as many scans at the same nominal scan speed. In the 6340, ETD and ETD+CID operating modes increase scan cycle times slightly compared to CID-only operation.

Click here for complete specifications for the 6300 Series Ion Trap LC/MS systems.


Built-in reliability

Agilent's patented orthogonal nebulization (spray) ion source design has often been imitated but never equaled. Orthogonal spray orientation keeps the capillary and ion optics cleaner. The fixed-position nebulizer requires no adjustments for flow rate or solvent composition changes.

All 6300 Series ion traps include a high-capacity drying gas system that improves spectral quality, sensitivity, and reproducibility by reducing solvent clusters and mobile phase adducts. Drying gas flow and temperature can be adjusted to match flow rate and solvent composition changes.

Together, orthogonal spray and high-capacity drying gas make Agilent's ion sources highly tolerant of non-volatile components in samples and mobile phases.



 
 