Agilent 1260 Infinity HPLC-Chip/MS System
|
HPLC-Chip/MS Interface or Chip-Cube For use with all Agilent 6000 Series Mass Spectrometersa.
Includes HPLC-Chip Cube, MS installation kit, orthogonal HPLC-Chip nanospray ion source with camera and monitor, ion source top plate with brushes for operation in chemical background reduction mode, Protein ID Chip #1 and MS calibration and diagnostic chip. IRM chemicals are included when ordering TOF and QTOF MS systems. Also includes all parts and flow control module for air make-up to the N2 MS drying gas line when operating the HPLC-Chip ion source in chemical background reduction mode.
aCompatible with Single Quad 6140 (HT version) only. |
G4240A |
Supported in Agilent ChemStation and Mass Hunter software. Requires a source of clean dry air with a pressure regulator a stable outlet pressure of at least 100 psi (8 bar) and a capacity of 10 L/min and ¼ inch Swagelok connector for operation in chemical background reduction mode.
IRM (Internal Reference Mass) components for the chip nanospray source are now included with G4240A HPLC-Chip/MS interface when it is ordered with TOF or QTOF MS systems. |
|
HPLC-Chip/MS installation. HPLC-Chip/MS familiarization at installation. |
#44K #44L |
Installation and familiarization are included in selected countries. Please consult your Agilent Sales Specialist for details. |
HPLC-Chip/MS Interface Accessories
|
Chemical background reduction site preparation kit. Provides necessary parts and flow control module for air make-up to the N2 MS drying gas line when operating the HPLC-Chip ion source in chemical background reduction mode. Requires a source of clean dry air with a pressure regulator of least 100 psi (8 bar) capacity and ¼ inch Swagelok connector. |
G1995A |
Required for the operation of the HPLC-Chip/MS system in low background mode. All G4240A HPLC-Chip/MS systems shipped after February 01, 2007 already contain this kit by default. |
|
HPLC-Chip enablement kit for Agilent TOF MS For use with Agilent G3250AA TOF MS. Provides required ion source upgrade parts and software for G3250AA TOF’s shipped prior to June 2006, (SN < US62400800). |
G1984A |
Used to enable HPLC-Chip/MS to be used on Agilent TOF MS shipped prior to June 2006. |
|
Replacement top plate for HPLC-Chip nanoelectrospray source |
G1982-60359 |
For use with G4240A HPLC-Chip/MS interface only |
|
IRM high mass compound (HP-1221) |
G1982-85001 |
To be used with Universal Internal Reference Mass (UIRM). |
|
IRM high mass solvent (Fluorinert™ FC-70) |
G1982-85002 |
|
IRM low mass compound (methyl stearate) |
G1982-85003 |
|
Inline Micro filter kit. Includes pre-assembled inline filter, 4 replacement 0.5 µm PEEK filter frit fittings, connection capillary and micro fittings. Approximate delay volume of 240 nL. |
5067-1582 |
An in-line filter is strongly recommended for biofluid samples or samples with high levels of particulates or containing high levels of proteins, lipids or other materials. The filter is installed in-line between the autosampler and the HPLC-Chip Cube. |
|
Replacement 0.5 µm PEEK filter frit fittings, pack of 10. |
5067-1584 |
|
Replacement micro fingertight fittings, 790 µm ID, PEEK. Pack of 10. |
5067-1585 |
|
Replacement connection capillary, 100 mm x 25 µm, 1/32” OD. PEEK/fused silica. |
G1375-87320 |
|
Phosphochip reagent pack Ready to use phosphopeptide elution buffer and column regeneration mix, and lyophilized conditioning/standard mix |
400600 |
For use with Phosphochip |
PEEK sample transfer capillary (25 µm x 100 cm) |
G4240-87309 |
Recommended for PhFor use with the mAb-Glyco Chiposphochip use or other applications for inertness or high pH operation up to pH10 |
| PEEK capillary for use with micro inline filter (25 µm x 10 cm) |
G4240-87310 |
| mAb-Glyco Chip Enablement Kit |
G4240-64025 |
Must be installed prior to first time use of the mAb-Glyco Chip Kit |
mAb-Glyco-Chip Reagent Pack Deglycosylation buffer and standards used with the mAb-Glyco Chip |
G4240-64022 |
For use with the mAb-Glyco Chip |
| mAb-Glyco Chip Deglycosylation buffer |
G4240-64023 |
For use with the mAb-Glyco Chip |
HPLC Chips
|
|
Original* |
HPLC-Chip II** |
|
|
Calibration & Maintenance |
|
Calib-Chip (II) |
G4240-61001 |
G4240-61010 |
MS calibration and diagnostic chip; requires a syringe pump. Agilent recommends the KDS100, Agilent PN 3162-0178 |
|
FIA-Chip (II) |
G4240-61002 |
G4240-61015 |
|
|
|
Original |
HPLC-Chip II |
|
|
Proteomics |
|
ProtID-Chip-43 (II) |
G4240-62001 |
G4240-62005 |
Rapid Protein ID, 43mm 300 A C18 chip w/40 nL trap column |
|
ProtID-Chip-150 (II) |
G4240-62002 |
G4240-62006 |
Better Separation, 150mm 300 A C18 chip w/ 40 nL trap column |
|
Large capacity Chip (II) |
G4240-63001 SPQ110 |
G4240-62010 |
High Capacity Loading, 150mm 300 A C18 chip w/ 160 nL trap column |
|
Phosphochip kit |
-- |
G4240-62020 |
For PTM analysis. Includes Phosphochip (II) (150 mm 300 A C18 chip w/ RP-TiO2-RP trap column) and Phosphochip reagent pack (P/N 400600) and PEEK Capillaries (P/N G4240-87309 and P/N G4240-87310) |
| Polaris-HR-Chip 3C18 |
-- |
G4240-62030 |
High Resolution Chip 150 mm 180A 3 µm C18 chip with 360 nL trap column 3 µm Polaris particles for improved resolutions and peak capacities mainly on peptides or proteins |
|
|
Original |
HPLC-Chip II |
|
|
Small Molecule Analysis |
|
SmMol-Chip-43 (II) |
G4240-65001 |
G4240-65005 |
Rapid analysis, 43mm 80 A C18 chip with 40 nL trap column |
|
UHC-Chip (II) |
G4240-63001 SPQ115 |
G4240-65010 |
150 mm 80 A C18 chip with 500 nL trap column |
| |
Original |
HPLC-Chip II |
|
| Biopharma |
|
|
|
mAb-Glyco Chip Kit Contains the mAb-Glyco Chip and chemicals needed for chip operation. The mAb-Glyco Chip Enablement Kit (G4240-64025) has to be installed prior to first time use. |
n/a |
G4240-64020 |
310 nL enzyme reactor (PNGase F), 43mm porous graphitized carbon chip with 40 nL trap column |
|
|
Original |
HPLC-Chip II |
|
|
Other Applications (carbohydrates, nucleotides, etc.) |
|
PGC-Chip (II) |
G4240-62003 |
G4240-64010 |
43mm porous graphitized carbon chip with 40 nL trap column |
|
|
Original |
HPLC-Chip II |
|
|
Custom Chips |
|
Dir-Inj-Chip (II) |
G4240-63001 SPQ100 |
150mm 300 A C18 chip w/ 16 nL void |
|
Protein-Chip (II) |
G4240-63001 SPQ105 |
43mm 300 A C8 chip w/40 nL trap column |
|
Customizable Chip (you name it) |
Special SPQ Number |
Design your own chip and ask for a special quote |
|
Instructions for custom chip quotes: Please email chip_pdl-wadquotes@agilent.com for a special quote or any custom chip order (P/N G4240-63001). Please copy your Agilent account manager/product specialist on the email. A special SPQ (special price quote) number will be issued in the quote. A minimum 2 custom chips per order is required. Please provide the following information:
- Stationary phases information (most phases offered from Agilent columns will be available on chip, for special phase materials, customer may need to ship the material to Agilent in Germany)
- Enrichment column (phase, pore size, and particle size, i.e. C18, 300 Å, and 5 µm)
- Separation column (same as above)
- Column sizes for enrichment column (40 nL, 160 nL or 500 nL) and separation column
(43 mm or 150 mm)
- Please reference SPQ numbers for each chip type in PO (purchase order)
Delivery of chips is 4-6 weeks after receipt of order. |
NOTES
Availability *Obsolete; ** Now Available |
|
|