Future Proof – Backwards Compatible: The Agilent 1200 Infinity Series offers a constant stream of innovations to keep your Agilent LC at the forefront of separation. Visit our technology pages to learn more about it.


New Level in Quaternary Pump Performance
The new Agilent 1290 Infinity Quaternary Pump is the only low-pressure mixing UHPLC pump offering the accuracy and precision of a high-pressure mixing binary pump. This unique combination enables the most accurate and reliable analysis, combined with the flexibility of ternary and quaternary gradients, precise buffer blending, and method development capability.
30x Wider Linear UV-Range
The Agilent 1200 Infinity Series High Dynamic Range DAD Solution computes the signals of two diode array detectors (DAD) with Max-Light flow cells of different path lengths to achieve an outstanding increase in detection linearity.
Hybrid SFC/UHPLC System
The Agilent 1260 Infinity Hybrid SFC/UHPLC System packs two orthogonal separation modes into one instrument, bringing you more information from a single automated sequence.
One-click System Emulation
The Agilent 1290 Infinity LC with Intelligent System Emulation Technology (ISET) emulates other HPLC and UHPLC instruments by a simple mouse click – for secure and comfortable instrument-to-instrument method transfer.
Plug & Play: Empower, Chromeleon, Atlas, ...
The Agilent Instrument Control Framework (ICF) allows easy, fast, secure and cost-effective integration of Agilent LC Systems into non-Agilent software.
Design-For-Supportability
The Agilent Lab Advisor is a platform independent software tool set with data sharing and reporting capability for diagnostics, maintenance and calibration of Agilent (U)HPLC & CE instruments.
Valve-based Workflow Automation
The Agilent 1200 Infinity Series Valve portfolio enables a broad range of application- and workflow-specific automation solutions like columns and solvent switching, automated method development, matrix-stripping, 2D-LC, online-SPE, and many more.
Truly Bio-inert UHPLC System
The Agilent 1260 Infinity Bio-inert Quaternary (U)HPLC System for small and large molecule analysis providing highest robustness and highest sample yield – most versatile and 100% bio-inert.
Orthogonal Separation by CE
The Agilent 7100 Capillary Electrophoresis system enables high-resolution separation, detection, and quantitation of charged compounds, offering a flexible platform and wide variety of detectors for all CE modes.
Intelligent Reporting
The Agilent OpenLAB Intelligent Reporting is a fast custom reporting application in OpenLAB CDS ChemStation and EZChrom Edition with advanced in-built calculations modules.
 
 
 