Specifications Agilent 1200 Series Valves |
| Agilent 1200 Series 2-position / 10-port valve (G1157A)(Dual sided MBBTM) |
| Liquid contacts |
Stainless steel and PEEK |
| Port size |
Accepts 10–32 male threaded fittings |
| Flow passage diameters |
Stator and stator face assembly 0.60-mm (0.024"), rotor seal 0.60-mm (0.024") |
| Volume in flow passages |
Stator (includes stator face seal)2.1-µL/hole, rotor seal- 0.7-µL/groove |
| Maximum pressure |
41 MPa (408 bar, 6000 psi) |
| Agilent 1200 Series 6-position selection valve (G1159A) |
| Liquid contacts |
Stainless steel and PEEK |
| Port size |
Accepts 10-32 male threaded fittings |
| Flow passage diameters |
Stator 0.6-mm (0.024"), stator face assembly and rotor seal 0.4-mm (0.015") |
| Volume in flow passages |
Angled ports 1, 3, 5 (15,6 µl), Radial ports 2, 4, 6 (18,8 µl) |
| Maximum pressure |
35 MPa (345 bar, 5000 psi) |
| Agilent 1200 Series 12-postion / 13-port selection valve (G1160A) |
| Liquid contacts |
Stainless steel and PEEK |
| Port size |
Accepts 10-32 male threaded fittings |
| Flow passage diameters |
1.0-mm (0.040") |
| Volume in flow passages |
Stator (includes stator face seal), 6.4-µL/hole, rotor seal 4.0-µL/groove |
| Maximum pressure |
21 MPa (207 bar, 3000 psi) |
| Agilent 1200 Series 2-position / 6-port valve (G1158A) |
| Liquid contacts |
Stainless steel, PEEK, and alumina ceramic |
| Port size |
Accepts 10-32 male threaded fittings |
| Flow passage diameters |
0.4-mm (.015") and 0.5mm (.018") |
| Volume in flow passages |
Stator (includes the stator face assembly) 0.7 µL/hole, rotor seal- 0.3 µL/groove |
| Maximum pressure |
41 MPa, 408 bar, 6000 psi |
| Agilent 1200 Series 2-postion / 6-port micro valve (G1162A) |
| Liquid contacts |
DuraLife processed stainless steel and vespel |
| Port size |
Accepts M4 male threaded fittings |
| Flow passage diameters |
0.20-mm (0.008") |
| Volume in flow passages |
70 nL port to port |
| Maximum pressure |
41 MPa (408 bar, 6000 psi) |
| Agilent 1200 Series 2-postion / 10-port micro valve (G1163A) |
| Liquid contacts |
DuraLife processed stainless steel and vespel |
| Port size |
Accepts M4 male threaded fittings |
| Flow passage diameters |
0.20-mm (0.008") |
| Volume in flow passages |
Stator (20° ports) 27.2 nL, (45 ° ports), 30.5 nL, rotor seal-25.0 nL/groove |
| Maximum pressure |
41 MPa (408 bar, 6000 psi) |
Agilent 1200 Series 2-position / 6-port valve (G1316A#055) (in 1200 Series thermostatted column compartment) |
| Liquid contacts |
Stainless steel, vespel, aluminia, ceramic |
| Port size |
Accepts 10-32 male threaded fittings |
| Flow passage diameters |
0.4-mm (0.015") and 0.5-mm (0.018") |
| Volume in flow passages |
Stator (includes stator face assembly) 0.7 µL/hole, rotor seal- 0.3 µL/groove |
| Maximum pressure |
41 MPa (408 bar, 6000 psi) |
Agilent 1200 Series 2-position / 6-port valve (G1316B#055) (in 1200 Series thermostatted column compartment SL) |
| Liquid contacts |
UltraLife processed stainless steel and Ultralife PEEK-blend |
| Port size |
Accepts 10 - 32 male threaded fittings |
| Flow passage diameters |
0.30-mm (0.012") and 0.4 mm (0.015") |
| Volume in flow passages |
Stator 0.2 µL/hole, rotor seal 0.1 µL/groove |
| Maximum pressure |
62 MPa (620 bar, 9000 psi) |
Agilent 1200 Series 2-position / 6-port micro valve (G1316A#056) (in 1200 Series thermostatted column compartment) |
| Liquid contacts |
DuraLife processed stainless steel and vespel |
| Port size |
Accepts M4 male threaded fittings |
| Flow passage diameters |
0.20-mm (0.008") |
| Volume in flow passages |
70 nL port to port |
| Maximum pressure |
41 MPa (408 bar, 6000 psi) |
Agilent 1200 Series 2-position / 10-port valve (G1316A#057) (in 1200 Series thermostatted column compartment) |
| Liquid contacts |
Stainless steel (stator) and PEEK (stator-face and rotor seal) |
| Port size |
Accepts 10-32 male threaded fittings for 1/16-inch tubing |
| Flow passage diameters |
Stator and stator face seal- 0.61 mm (.024"), rotor seal-0.46 mm (0.018") |
| Volume in flow passages |
Stator (includes stator face seal)-2.2µL/hole, rotor seal-0.4µL/groove |
| Maximum pressure |
41MPa (408 bar, 6000 psi) |
Agilent 1200 Series 2-position / 10-port micro valve (G1316B#057) (in 1200 Series thermostatted column compartment SL) |
| Liquid contacts |
UltraLife processed stainless steel and Ultralife PEEK-blend |
| Port size |
Accepts M4 male fittings |
| Flow passage diameters |
0.2 mm (0.008") |
| Volume in flow passages |
Stator 24 - 26 nL, rotor seal- 39 nL/groove |
| Maximum pressure |
62 MPa (620 bar, 9000 psi) |
| Agilent 1200 Series thermostatted column compartment (G1316A) |
| Temperature range |
10 degrees below ambient to 80 °C |
| Temperature stability |
± 0.15 °C |
| Column capacity |
Three 30-cm columns |
| Agilent 1200 Series thermostatted column compartment (G1316B) |
| Temperature range |
10 degrees below ambient to 100 °C |
| Temperature stability |
± 0.05 °C |
| Column capacity |
Three 30-cm columns |