Description

Product Number

Capillary Flow Technology QuickSwap Option
For new Agilent GC/MSD systems that include a 6850 Series II, 6890, or 7890A GC

G3440A Option 885 (7890A GC)
G1530N Option 885 (6890 GC)
G2630B Option 885 (6850 GC)

Capillary Flow Technology QuickSwap Accessory

  • QuickSwap mounts at the end of the MSD transfer line inside the GC oven
  • Includes the Capillary Flow device and consumables
  • Requires a regulated inert purge gas supply
  • Pressure control device is required. If not present, order field upgrade: auxiliary EPC (G3394B for 6850 GC, G1570A for 6890 GC) or pneumatics control module (PCM) only

G3185B

QuickSwap Restrictors

Capillary Flow Technology Deans Switch Option

  • Some Capillary Flow components (for example, mounting hardware) is factory installed, but no system verification and no column installed.
  • Any on-site Capillary Flow system verification, using columns and sample that the customer provides, must be confirmed with your Agilent service engineer and quoted separately.

G3440A Option 888(7890A GC)
G1530N Option 888(6890 GC)

Capillary Flow Technology Deans Switch Accessory
Recommended on-site installation/verification to be quoted separately.

G2855B

Capillary Flow Technology Purged Effluent Splitter Option

  • Some splitter components (e.g., mounting hardware) factory installed, but no system verification.
  • Recommended on-site installation/verification to be quoted separately.

G3440A Option 889(7890A GC)
G1530N Option 889(6890 GC)

Capillary Flow Technology Purged Effluent Splitter Accessory
Recommended on-site installation/verification to be quoted separately.

G3180B

Capillary Flow Technology 3-way Splitter with Make-up (typical application is to split column effluent to three detectors)

  • Some splitter components (e.g,. mounting hardware) factory installed, but no system verification.
  • Recommended on-site installation/verification to be quoted separately.

G3440A Option 890(7890A GC)
G1530N Option 890(6890 GC)

Capillary Flow Technology 3-Way Splitter Accessory
Recommended on-site installation/verification to be quoted separately.

G3183B

Includes:

Hardware components for Capillary Flow switch or splitter

  • Surfaces that contact the sample are deactivated to help minimize active sites
  • Flow calculator software and documentation for flow calculations and required tubing lengths (English)
  • Hardware installation instructions (English)

Requires:

  • 7890A GC or 6890 GC with EPC
  • Two detectors (monitor and analytical detectors)
  • PCM if GC has only one inlet OR Auxiliary (Aux) EPC Module (acceptable, but PCM preferred--see Note below)
  • Two columns (pre-column and analytical column)
  • Windows 2000 or NT 4.0 (Service Pack 6), minimum 1024x768 pixel screen resolution and 16-bit color for Flow Calculator Software. 7890A GC requires NT4.0 (SP6)

Note: Both PCM and Aux EPC provide real-time ambient temperature compensation for retention time (RT) repeatability and stability. However, PCM also provides real-time atmospheric pressure compensation for even more precise RT repeatability and stability.

NOTE: Individual applications will vary but most switch systems will include two flow sources while most splitter systems will include two detectors.

Recommended:  

  • If a split/splitless inlet is not used, order Solvent Vapor Exit Accessory (Agilent part number G2399A) to accomplish back flushing
  • Agilent ChemStation
  • Automated sample introduction is recommended for best performance for reproducibility

 

Description

Product Number

Capillary Flow Technology GC x GC Flow Modulator Option
For new 7890A GC systems to enable comprehensive multidimensional chromatography

G3440A Option 887

Also requires:
G3487A Checkout Kit
(order separately)

Capillary Flow Technology GC x GC Flow Modulator Checkout Kit

Includes:

  • Checkout to confirm GC x GC modulation

G3487A

Capillary Flow Technology GCxGC Flow Modulator Accessory

For installation onto an existing 7890A GC system

G3486A

Includes:
Two columns:

  • 122-5532 (30m x 0.25mm x 0.25um DB-5ms)
  • 19091N-030 (5m x 0.25mm x 0.15um INNOWAX)

    Requires:
    G3440A 7890A GC, with:

  • SSL inlet
  • FID
  • Pneumatics Control Module
  • Automatic Liquid Injector
  • G2070BA SW (Ver B.03.02)

    Not Included:

  • 2D (GC x GC) data analysis software is not provided/supported by Agilent
  • Zoex Corporation sells and supports a 2D (GCxGC) data analysis software tested with 7890A GC system
  • For more information, see www.zoex.com/software-agilent.html

    Exclusions:

  • Operation with MSD or SCD not currently supported
  • Cannot operate with other Agilent GC platforms such as 6890 GC, 6850 GC
  •  
     