Choose an RNA or DNA application that generates the appropriate data for your experimental needs

Your experimental plan will dictate the genomic technique to use or measurement to make. Agilent has optimized and supports several RNA and DNA applications for transcript RNA and/or genomic DNA, including Gene Expression, array-based CGH (comparative genomic hybridization), and array-based ChIP (chromatin immunoprecipitation). In addition to these standard techniques, we have also printed microarrays for customers studying miRNA, siRNA, alternative splicing, methylation, and more. Agilent can generally print anything you need, even if we do not provide a processing protocol or an end-to-end processing solution.


Specify the organism you are representing

Agilent has an extensive library of pre-designed probes for a number of species. This library can be searched and the resulting probes re-purposed according to your custom needs. From a probe design perspective, specifying eukaryotic versus prokaryotic organisms allows us to optimize probe design according to the differing genome base composition of these biological groups.


Design probes against your target sequence database or select from our library, and submit to Agilent

You can use Agilent probes, your own probes, or a combination of both to design your custom microarray. If you are designing your own, we will provide design guidelines and data formats that are compatible with our systems. While our standard probe length is a 60-mer, we will print any length between 25 and 60 bases. For variable length probe sets, we can design tethers to generate uniform 60-mers or print variable length probes.


Choose an array format to accommodate the number of probes you wish to print

Agilent offers a variety of microarray formats to choose from according to your application and content requirements. All of our microarrays are built on industry-standard 1 x 3 inch glass slides. Our microarray formats include 1 x 244K, 2 x 105K, 4 x 44K, and 8 x 15K.


Design the microarray yourself using eArray or engage our team's Professional Consulting Services

Customers have two options for generating their designs with Agilent. The most efficient and economical path is via eArray, our web design application that puts the power of our design and manufacturing capabilities in your hands. For conventional applications and experienced genomics data managers, eArray is a powerful tool that puts you in control of project management. For boutique applications or less experienced customers, Agilent continues to offer acomprehensive consulting service for probe design, annotation, genome assembly, and more.


Order microarrays through eArray or through your Agilent local sales representative

Custom microarrays and related designs services cannot be purchased through standard Agilent e-channels because of the nature of pricing customer specifications. For pricing information, contact your Agilent local sales representative. Once designs are complete and a valid order is opened, microarray deliveries can be requested using either eArray or by contacting you sales rep. In either case, your microarrays will be delivered in weeks, not months.

Agilent custom microarrays offer customers maximum content flexibility, state-of-the-art manufacturing and quality control, and project management value that is unsurpassed in the industry. Call us today to discuss your specific project needs and we'll get you started down the path to scientific success.

 
 
 