Help save the planet with the easy-to-use Agilent Renewable Gas Purification System

By Lindy Miller
Agilent Product Manager

An innovation that helps to increase overall productivity in a high throughput forensics or environmental lab is always good. When it also helps to protect the environment, it’s even better.

Agilent’s new Renewable Gas Purification System is just such an innovation. It removes common gas contaminants to help you attain the detection levels and efficiency you need, while also reducing the amount of potentially hazardous waste sent to landfills.

Use the Renewable Gas Purification System and you’ll discover that it is:

  • Powerful. Its high capacity allows one system to support up to 4 GCs and ensures you’ll replace cartridges less often.
  • Easy to install. The system is designed for easy setup and cartridge changes are quick and easy.
  • Easy to use. Color indicators make it easy to see purification results.
  • Easy on the environment. Simply send your used cartridges to Agilent for recycling and reduce waste.

A powerful, high-capacity solution

Our new Renewable Gas Purification System is designed to do more with less. A single renewable cartridge filters 850 cc oxygen, 12 grams H20 and 8 grams n-butane (filtration of hydrocarbons varies by type) and improves 99.995% gas purity to 99.9995%. Other purification systems may require multiple cartridges to achieve the same filtration capacity.

Not only does each cartridge do a better job of filtering more types of contaminants, it also handles more volume overall. Each single cartridge is designed to filter approximately 20 cylinders of gases. Even better, each single cartridge supports up to four GC systems.

The Renewable Gas Purification System’s high capacity means you’ll be purchasing replacement cartridges less frequently. Based on average flow rate and consumption estimates, you should need to replace your cartridge only once a year. When it is time to replace the cartridge, instead of sending it to the landfill, send it back to Agilent for regeneration. You may choose a new cartridge or a regenerated replacement cartridge. Regenerated cartridges have the same specifications and effectiveness at a lower price – saving you money while helping to save the environment.

A convenient, easy to use system

Unlike the cumbersome gas traps of the past, the Renewable Gas Purification System consists of a small wall- or bench-mountable base and a single tri-functional purification cartridge. A simple twist on/off knob and a guide rod make cartridge changes – when they are needed – quick and easy.

Dual indicators make it easy to see the purification results and to monitor use, so your recyclable cartridge can be replaced before contaminants break through and cause unscheduled downtime. Thoughtful labelling shows indicator color to make accurate reading quick and easy.

Designed to be environmentally friendly

If you’re concerned about hazardous waste materials and are looking for environmentally friendly products for your lab, the Renewable Gas Purification System is an excellent place to start. It has an environmentally friendly design that:

  • Reduces waste because the system uses less material and each cartridge is completely recyclable. Plus, the use of regenerated replacement cartridges further reduces the need for materials.
  • Prevents most adsorbent spills thanks to iterative seals which virtually eliminate cartridge breakage.
  • Increases capacity and minimizes the use of hazardous materials with an optimized length to diameter ratio.

Even your replacement cartridge is shipped in an environmentally responsible manner. The rugged nature of the cartridge housing requires less packaging materials, and only those materials that are environmentally friendly and recyclable are used.

Achieve greater productivity and create less waste.

Agilent’s Renewable Gas Purification System provides greater detection levels, power, and convenience, so you use fewer cartridges and waste fewer resources to get superior results. That’s a combination that will help you increase productivity and save money while working in an environmentally responsible way.

It’s a combination that will find favor with anyone who is productivity and environmentally minded. Learn more about the Renewable Gas Purification System and what it can do for you.

 
 