Method Page for GPA 2177-90, AC


GPA 2177-90, AC 
 
Analysis of Demethanized Hydrocarbon Liquid Mixtures Containing N2 and CO2 
Determination of nitrogen, carbon dioxide, methane, ethane, propane, isobutane, n-butane and 2,2-dimethylpropane, isopentane, n-pentane, 2,2-dimethylbutane, 2,3-dimethylbutane and 2-methylpentane, 3-methylpentane and cyclopentane, n-hexane, heptanes and heavier.
 
 
Recommended Agilent Technologies Column(s)
Part #Description
19096A-030 30 % SE-30 on Chromosorb P 80/100
19096A-002 30 % SE-30 on Chromosorb P 80/100
19096A-010 Molecular Sieve 13X 45/60


Sample Chromatogram

 
 
 
 
Product Information
Agilent 6890N GC
 
 
Contact Information
AC Analytical Controls
BV PO Box 10054, Innsbruckweg 35 3047 AG Rotterdam the Netherlands 
+31-10-462 4811    +31-10-462 6330 fax