Last  Updated: 06-Mar-08

Tested and Supported Configuration          (This web page requires Microsoft Internet Explorer)

 

The Operating System(s), MS Internet Explorer and the Oracle 9i versions with the associated Service Packs or Patch Set mentioned in the tables bellow are the recommended and fully supported versions.

The usage of other Service Packs, Security Patches, Patch Sets issued by manufacturer (e.g. Microsoft, Oracle) is supported on a best effort basis.

Software maintenance is available for defects that are reproducible in the recommended and fully supported version of the Operating System Service Pack.

 

· Rev B.04.01

· Rev B.03.03 SR2

· Rev B.03.02 SR3

· Rev B.03.01 SR2

· MS Windows Hot fixes 2008

· MS Windows Hot fixes 2007                                                                                                                             ChemStore main page

· MS Windows Hot fixes 2006                                                                                  ChemStation/ChemStore compatibility matrix

 Rev. B.04.01

ChemStore Stand-alone

ChemStore Client

Database server

Terminal server

 ChemStation     (LC, LC/MSD, GC,      

                            CE, CE/MSD, A/D)

B.03.01 SP 1 or 1.1

û

û

û

û

B.03.02

ü

ü

l

m

   Windows XP Professional

 

 

 

ü

l

 

ü

 

 

 

û

 

 

 

û

+      Service Pack

SP2

ü

 

ü

ü

 

ü

û

û

SP3

l

l

û

û

  Windows Vista

û

û

û

û

  Windows 2003 Server / Adv. Server

 

 

 

 

+      Service Pack

SP2

 l 

 l 

ü

m

+      Terminal Services

-

-

l

m

+      Clustering Services

-

-

l

l

  Windows 2003 R2 Server / Adv. Server  32 bit

 

 

 

 

+      Service Pack

SP1

 l 

 l 

 l 

 l 

SP2

 l 

 l 

ü

m

+      Terminal Services

-

-

l

m

+      Clustering Services

-

-

l

l

Windows 2003 R2 Server / Adv. Server   64 bit

 l 

 l 

 l 

 l 

   MS Internet Explorer 

6.0  SP2

ü

ü

ü

m

7.0

ü

ü

ü

m

   Internet Information Server

-

-

6.0 for W2003

6.0 for W2003

   MDAC

2.8

2.8

2.8

2.8

  Java Runtime 

1.6.0_02-b06

 l 

ü

ü

m

1.6.0 03-b07

l 

ü

ü

m

   Oracle 10g Release 2

 

 

 

 

+      RDBMS

10.2.0.1

û

û

û

û

10.2.0.2

û

û

û

û

10.2.0.3

l

l

ü1

û

6637237 (*)

 l 

 l 

ü

û

+      Client

10.2.0.3

l

ü

l

m

5699495 (#)

 l 

ü

l

m

+      OLE DB Provider

10.2.0.3

 l 

ü

l 

l 

+      Oracle Fail Safe (OFS)

-

-

l 

û

+      Oracle Transparent Failover (TAF)

-

-

û

û

+      Real Application Clustering (RAC)

-

-

û

û

Citrix Terminal Server

û

û

û

m

Citrix Metaframe XP a

Citrix Metaframe XP s

Citrix Metaframe XP e

û

û

û

m

ü

û

û

û

m

û

û

û

m

Citrix Client

û

m

û

û

Unix

û

û

ü3

û

HPUX  11.11  (11i),  32 or 64-bit

-

-

ü

û

HPUX  11.20 or higher

-

-

 l 

û

Sun Solaris

-

-

 l 

û

Notes

1 Oracle Enterprise Edition is supported with ChemStore server, however it has not been tested.

2 Oracle Standard Edition is tested and supported with ChemStore

3 ChemStore archive server service is not supported on UNIX. This service needs to be operated on a Windows operating system.

*) Oracle Critical Patch update January 2008

#) Oracle ODBC driver patch

l    Not tested

ü             Tested and fully supported

m               Currently under testing

!                  Limited support

û    Not supported