| Run
Conditions: |
| Columns: |
30
m x 0.25 mm id, 0.25 id, 0.25 mm |
| Carrier Gas: |
Helium
at 35 cm/sec, measured at 50°C |
| Oven: |
50°C
for 1 min |
| 50-100°C
at 25°/min |
| 100-300°C
at 5°/min (DB-1701 ramped to 280°C) |
| 300°C
for 5 min (DB-1701 held at 280°C for 10 min) |
|
| Alphabetical
Order By Analyte |
| Compound |
DB-5ms |
DB-XLB |
DB-35ms |
DB-17ms |
DB-1701 |
| Alachlor |
24.29 |
25.84 |
27.4 |
27.91 |
27.59 |
| Aldrin |
25.99 |
27.33 |
28.28 |
28.54 |
26.79 |
| Aspon |
25.72 |
26.69 |
28.11 |
27.55 |
28.22 |
| Atrazine |
21.11 |
22.65 |
24.82 |
24.5 |
25.12 |
| Azinphos-ethyl |
37.51 |
39.94 |
43.31 |
43.27 |
48.74 |
| Azinphos-methyl |
36.28 |
38.83 |
42.6 |
42.75 |
45.86 |
| a-BHC |
20.01 |
21.83 |
23.5 |
23.83 |
23.06 |
| ß-BHC |
21.12 |
24.95 |
26.62 |
26.7 |
24.84 |
| ÿ-BHC |
21.46 |
23.37 |
25.32 |
25.73 |
27.97 |
| ð-BHC |
22.7 |
25.98 |
27.83 |
28.08 |
28.89 |
| Bolstar |
32.16 |
33.89 |
36.25 |
35.94 |
34.96 |
| 1-Bromo-2-nitrobenzene(IS) |
11.5 |
12.73 |
14.87 |
15.66 |
14.68 |
| 2-Bromobiphenyl(SS) |
17.31 |
18.49 |
20.24 |
21.01 |
18.62 |
| Captafol |
33.91 |
36.35 |
39.46 |
40.31 |
40.4 |
| Captan |
27.98 |
30.15 |
33.2 |
34.14 |
32.25 |
| Carbophenothion |
32.56 |
34.49 |
36.69 |
36.26 |
35.48 |
| -Chlordane |
28.54 |
30.72 |
31.77 |
31.91 |
30.91 |
| -Chlordane |
29.06 |
30.9 |
32.19 |
32.43 |
31.21 |
| Chlorfenvinphos |
27.61 |
29.34 |
31.47 |
31.15 |
31.02 |
| 4-Chloro-3-nitrobenzotrifluoride
(SS) |
7.66 |
8.55 |
8.83 |
8.59 |
10 |
| Chlorobenzilate |
31.28 |
32.82 |
34.03 |
34.27 |
33.78 |
| Chloroneb |
15.53 |
16.87 |
18.68 |
19.37 |
17.92 |
| Chloropropylate |
31.28 |
32.92 |
34.48 |
34.85 |
33.98 |
| Chlorothalonil |
22.16 |
26.44 |
28.06 |
28.08 |
27.73 |
| Chlorpyrifos |
25.84 |
27.52 |
29.31 |
28.86 |
28.36 |
| Chlorpyrifos-methyl |
23.86 |
25.64 |
27.79 |
27.55 |
26.7 |
| Coumaphos |
38.74 |
41.4 |
44.01 |
43.52 |
|
| Crotoxyphos |
28.16 |
29.48 |
32.13 |
32.09 |
31.89 |
| Dacthal |
26.11 |
27.55 |
29.13 |
29.61 |
28.82 |
| p,p’-DDD |
31.62 |
33.93 |
35.6 |
35.92 |
34.6 |
| p,p’-DDE |
29.97 |
31.82 |
33.2 |
33.53 |
31.5 |
| p,p’-DDT |
33.07 |
35.12 |
36.71 |
37.05 |
35.37 |
| Demeton-O |
17.91 |
18.97 |
20.58 |
20.13 |
20.49 |
| Demeton-S |
20.52 |
21.83 |
24.03 |
23.67 |
24.05 |
| Diallate
A |
19.88 |
20.87 |
21.97 |
22.31 |
21.42 |
| Diallate
B |
20.26 |
21.35 |
22.4 |
22.71 |
22.1 |
| Diazinon |
21.99 |
23.05 |
24.59 |
24.21 |
24.16 |
| 1,2-Dibromo-3-chloropropane |
6.63 |
7.11 |
8.05 |
8.47 |
7.9 |
| ,-Dibromo-m-xylene |
16.72 |
18.27 |
20.6 |
21.4 |
19.41 |
| Dibutylchlorendate(SS) |
36.32 |
37.75 |
38.67 |
38.74 |
39.65 |
| Dichlofenthion |
23.64 |
25.07 |
26.58 |
26.02 |
26.02 |
| Dichlorvos |
9.31 |
9.93 |
11.53 |
11.39 |
12.45 |
| Dicrotophos |
19.12 |
20.58 |
23.77 |
23.98 |
24.66 |
| Dieldrin |
30.14 |
32.03 |
33.59 |
33.9 |
32.16 |
| Dimethoate |
20.52 |
22.32 |
25.8 |
26.02 |
26.7 |
| Dioxathion |
21.41 |
22.78 |
25.53 |
25.49 |
24.8 |
| Disulfoton |
22.37 |
23.68 |
25.53 |
25.09 |
24.95 |
| Endosulfan
I |
29.06 |
30.95 |
32.37 |
32.61 |
30.72 |
| Endosulfan
II |
31.39 |
34.11 |
36.04 |
36.36 |
34.97 |
| Endosulfan
sulfate |
32.88 |
35.74 |
37.84 |
38.13 |
38.91 |
| Endrin |
31 |
32.92 |
34.89 |
35.35 |
32.97 |
| Endrin
aldehyde |
31.96 |
34.57 |
37 |
37.52 |
37.01 |
| Endrin
ketone |
34.68 |
37.26 |
40.23 |
40.99 |
41.57 |
| EPN |
34.86 |
37.04 |
39.61 |
39.26 |
41.19 |
| Ethion |
31.55 |
33.09 |
35.39 |
35.11 |
34.85 |
| Ethoprop |
18.47 |
19.6 |
21.42 |
21.02 |
21.29 |
| Ethylparathion |
26.17 |
28.09 |
29.94 |
29.36 |
30.1 |
| Famphur |
32.38 |
34.38 |
37.69 |
37.72 |
39.69 |
| Fenitrothion |
25.19 |
26.96 |
29.47 |
29.22 |
29.36 |
| Fensulfothion |
31.25 |
33.31 |
36.44 |
36.36 |
37.1 |
| Fenthion |
26.02 |
27.62 |
30.25 |
30.22 |
29.07 |
| Fonofos |
21.76 |
23.19 |
25.29 |
25.03 |
24.41 |
| Heptachlor |
24.52 |
25.98 |
26.92 |
27.11 |
25.69 |
| Heptachlor
epoxide |
27.59 |
29.32 |
30.76 |
31.07 |
29.68 |
| Hexachlorobenzene |
20.12 |
22.13 |
22.91 |
23.01 |
21.03 |
| Hexachlorocyclopentadiene |
11.42 |
11.94 |
12.08 |
12.25 |
11.6 |
| Hexamethylphosphoramide |
10.25 |
11.1 |
12.74 |
12.54 |
15.46 |
| Isodrin |
27.17 |
28.71 |
30.1 |
30.48 |
28.44 |
| Kelthane |
35.37 |
37.59 |
39.54 |
39.91 |
|
| Kelthane
Decomp. Product |
26.57 |
28.71 |
30.35 |
30.68 |
|
| Leptophos |
36.17 |
38.15 |
40.73 |
40.55 |
40.94 |
| Malathion |
25.62 |
26.96 |
29.31 |
29.13 |
29.2 |
| Merphos |
30.01 |
31.47 |
32.94 |
32.22 |
31.89 |
| Methoxychlor |
35.22 |
37.05 |
39.54 |
40.31 |
38.91 |
| Methylparathion |
24.14 |
26.14 |
28.56 |
28.22 |
28.57 |
| Mevinphos |
13.5 |
14.48 |
16.72 |
16.69 |
17.56 |
| Mirex |
37.09 |
39.12 |
40.67 |
40.99 |
37.96 |
| Monocrotophos |
19.55 |
21.15 |
24.7 |
24.97 |
26.5 |
| Naled |
18.86 |
20.15 |
22.72 |
22.7 |
22.41 |
| trans-Nonachlor |
29.18 |
31.15 |
31.91 |
31.91 |
31.29 |
| Pentachloronitrobenzene
(IS) |
21.22 |
23.47 |
24.84 |
25.08 |
23.64 |
| cis-Permethrine |
38.62 |
40.27 |
42.12 |
42.53 |
42.25 |
| trans-Permethrine |
38.89 |
40.57 |
42.42 |
42.8 |
46.52 |
| Perthane |
31 |
32.67 |
34.29 |
34.68 |
32.51 |
| Phorate |
19.79 |
21.02 |
22.85 |
22.45 |
22.33 |
| Phosmet |
34.73 |
37.24 |
40.83 |
40.91 |
42.38 |
| Phosphamidon |
23.56 |
23.4 |
27.79 |
27.72 |
28.85 |
| Propachlor |
17.88 |
19.32 |
21.17 |
21.81 |
21.74 |
| Ronnel |
24.58 |
26.14 |
27.95 |
27.55 |
27.1 |
| Simazine |
20.91 |
22.65 |
25.05 |
24.87 |
25.23 |
| Stirophos |
28.66 |
30.5 |
32.94 |
32.69 |
32.27 |
| Sulfotep |
19.37 |
20.42 |
22.46 |
22.27 |
22.56 |
| TEPP |
16.76 |
17.91 |
20.69 |
20.74 |
21.98 |
| Terbufos |
21.64 |
22.78 |
24.23 |
23.67 |
23.91 |
| Terrazole |
14.17 |
15.12 |
16.6 |
17.25 |
15.86 |
| Tetrachloro-m-xylene
(SS) |
18.12 |
19.81 |
20.24 |
20.32 |
18.7 |
| Thionazin |
17.72 |
18.97 |
21.26 |
21.12 |
20.85 |
| Tokuthion |
29.55 |
31.19 |
32.83 |
32.22 |
31.67 |
| Trichloronate |
26.51 |
28.09 |
29.31 |
28.59 |
28.57 |
| Trifluralin |
19.3 |
20.35 |
19.98 |
19.47 |
22.15 |
| Tri-o-cresylphosphate |
36.64 |
38.4 |
40.93 |
40.83 |
42.62 |