A Flowmeter for Every Need!
Most are available for less than $500, including:
Agilent offers flowmeters for measuring capillary
column flows, calibrating air pumps and flow controllers, and verifying instrument gas
flows.
Setting and maintaining GC flow rates greatly affect the instrument
accuracy and sensitivity. Choosing a flowmeter for your application depends upon
measurement speed, ease of use, accuracy and flow rate range.
Agilent offers a flowmeter
recalibration and repair program. Learn
more
about this program.
Measurement
Speed
Agilent offers two types of volumetric flowmeters
bubble (Humonics Optiflow) and acoustic displacement (ADM series) and one mass
flowmeter (Humonics Veri-Flow 500).
Volumetric measurements rely upon the volume of gas
passing through the flowmeter but not the composition. Additionally, volumetric flowmeters
accurately measure from a mixed or multi-component gas stream. Mass flowmeters are
calibrated to specific gas compositions and determine the flow rate for those calibrated
gases. Mass measurements are independent of temperature and pressure.
With volumetric flowmeters, no adjustments are needed when switching
from one gas stream to a different composition stream. So, an analyst can immediately
change from measuring nitrogen from a GC detector to helium split rate from an injection
port, to methane from an anaerobic digestion vessel. If a mass flowmeter is used, the
analyst must change instrument settings and purge the flowmeter of the initial gas before
accurate readings can be taken.
Ease of
Use
When setting gas flows with many flowmeters, the analyst often needs
more than two hands to hold and start the flowmeter. With continuous flow readings, the
analyst does not have to start or stop the flowmeter with each measurement. The
Veri-Flow 500 and ADM flowmeters read flow values continuously.
Flow
Rate Range
Low flow rates? No problem (down to 0.1 mL/min). Very high flow
rates? No problem (up to 25 L/min). A wide range of flow rates? No problem (0.10-1000
mL/min using a single flowmeter).
Accuracy
Agilent accurately calibrates all flowmeters to NIST-traceable
standards.
Which flowmeter should I use?
Refer to our Flowmeter
Selection Guide for a complete guide.
| Flowmeter
Type |
Main
Feature |
Flow
Rate Range (Low) |
Flow
Rate Range (High) |
What
is Measured? |
| ADM Series |
Ease of Use |
0.1
mL/min |
1 L/min |
Noncorrosive Gases |
| Veri-Flow 500 |
Versatility |
5
mL/min |
500
mL/min |
He, H2, Air, N2,
Ar/CH4 |
| Optiflow (Digital Bubble) |
Dependability |
0.1
mL/min |
25 L/min |
All Gases |
| Liquid Flowmeter |
Liquid Flow |
1.0
mL/min |
30
mL/min |
Liquids |
.
|