LC Chromatograms Industry Listing

Click here for specific information about Agilent phases. We'll continue to add more chromatograms so keep checking back!

Life Science Listing

Chromatogram Agilent Phase Agilent Part No.
Alkyl Resin: Gel Permeation Chromatography Using Plgel Columns Plgel Columns 79911GP-501
79911GP-502
79911GP-504
Amino Acid- Standards Amino Acid (C18) 79915AA-572
Analgesics- High Speed CombiHT Isocratic Separation CombiHT SB-C18 870050-902
Analgesics: High Speed Separation ZORBAX SB-C18 833975-902
Analgesics: Non-Steroidal Anti-Inflammatory Drugs: Narrow Bore Separation ZORBAX Eclipse XDB-C8 993700-906
Anesthetics, Local: Bonded Phase Selectivity ZORBAX SB-C18
ZORBAX SB-C8
ZORBAX SB-Phenyl
ZORBAX SB-C3
ZORBAX SB-CN
883975-902
883975-906
883975-912
883975-909
883975-905
Antibodies: Fast Separation of IgM and IgG Antibodies GF-250 884973-701
Antibodies: High Speed Separation ZORBAX SB-C8 866953-906
Antibodies: Separation on ZORBAX Bio Series SAX Bio-SAX 820944-903
Antidepressants: Separation of Highly Basic Antidepressants Above Their pKa in Free Base Form Extend-C18 773450-902
Antidepressants, Tricyclic: Comparative Separation Bonus-RP 883668-901
Antifungal Medications ZORBAX Bonus-RP 883668-901
Antihistamines ZORBAX Rx
ZORBAX SB-C8
883967-901
883975-906
Aromatic Acids/Benzoic Acids - Selectivity Differences ZORBAX SB-C8
ZORBAX SB-CN
ZORBAX SB-Phenyl
880975-906
880975-905
880975-912
Aspirin and Cough Remedy ZORBAX XDB-C8 993967-906
Chromatographic Improvement at High pH Using Amines Asahipak ODP-50 79923OP-564
Separation of Small Molecule Anorectics on Bonus-RP and Traditional Alkyl Phase Bonus-RP 883668-901
b-Blocker Drugs: Silica-Based Column Aging at pH 11 XDB-C8 993967-906
Catecholamines/Biogenic Amines: Rapid Separation Using Ion Pair Reagents ZORBAX SB-C8 866953-906
Cephalosporins C8 883952-706
Chelating Agents Using Purospher Purospher RP-18 79925PU-564
Chiral Ethiazide (diuretic drug) Separation on Ultron ES-OVM Ultron ES-OVM 702111-651
Chiral Separation of Atenol on Ultron ES-Pepsin Ultron ES-Pepsin 82111631
Chiral Separation of D, L. Methadone and D, L. Norgestral ChiraDex 79925CB-584
Chiral Separation of Fluoxetine Enantiomers (Prozac) Using ES-OVM Ulton ES-OVM 702111-651
Chiral Separation of S- and R-Norfluoxetine Using Ultron ES-Pepsin Ulton ES-Pepsin 724111653
Chiral Separation of Salbutamol on Ultron ES-Pepsin Ultron ES-Pepsin 822111-631
Chiral Separation of Hexobarbitol ChiraDex 79925CB-584
Chiral Separation of Tolperison Enantiomers on Ultron ES-OVM Ultron ES-OVM 702111-651
Cocaine and Metabolites ZORBAX Rx-Sil 883975-901
Combinatorial Chemistry: Fast Gradient Analysis and Re-Equilibration Eclipse XDB-C18 933975-902
Cough Formula Mixture Eclipse SB-CN 883975-905
Dexamethasone, USP Method: Rapid Analysis ZORBAX SB-C8 880975-906
866953-906
Dextrane Characteristics Using GPC ZORBAX PSM-60
ZORBAX PSM-300
880957-801
880957-805
DHPLC of p53 Exon 8 Eclipse dsDNA 945750-902
dsDNA Restriction Digest Separations Eclipse dsDNA 993850-902
992750-902
Eclipse dsDNA Eclipse dsDNA 945750-902
Epoxy Resins: Detection Comparison Plgel Mixed-D 79911GP-MXD
USP Method: Glyburide and Internal Standard, Progesterone ZORBAX Eclipse XDB-C8 990967-906
Metramidazole: Updating USP Methods ZORBAX C8
ZORBAX Eclipse XDB-C8
ZORBAX Eclipse XDB-C8
883952-706
993967-906
963967-906
Morphine and Metabolites: Extracted Blood Plasma Sample Separation ZORBAX SB-C18 863953-902
Nucleotides: Separation of Mononucleotides SAX 880952-703
Neutraceuticals: Hypericin Separation in St. John's Wort ZORBAX Eclipse XDB-C8 993967-906
Nucleosides: Separation of Deoxy and Ribonucleosides ZORBAX SB-C3 883975-909
Nucleotides: Separation of Mononucleotides SAX 880952-703
Nucleotides: Using Rapid Separation 3.5µm Columns SB-CN 883975-905
835975-905
Oligonucleotides: Separation of 24 and 25-mer Oligo 820940-901
Oligonucleotides: Separation of Standard p(DT) Oligo 820940-901
Opiate Drugs, Basic Compounds Showing Good Peak Shape ZORBAX Rx 883967-901
883975-906
Oxindole Alkaloids ZORBAX Rx-C18 880967-902
Peptides: Aspartate Aminotransferase Tryptic Digest Vydac C18 79918O3-581
Peptides: Comparison of Mass Spectra of Angiotensin I with TFA and NH4OH Mobile Phase Extend-C18 773700-902
Peptides: Effect of TFA Concentration 300 SB-C8 883995-906
Peptide/Proteins: Effect of Elevated Temperature 300 SB-C3 883995-909
Peptide/Proteins: Equivalent Gradient Separation 300 SB-C8
300 SB-C8
883995-906
883750-906
Peptide/Proteins: Rapid Analysis Using Ion Exchange TSK 79912SP-324
Peptides: SEC Separation of Cyanogen Bromide Fragments TSK 3000SW 79912S3-197
Peptides: Separation of Angiotensins I, II, III with TFA and NH4OH3 Extend-C18 773700-902
Polybutadiene: GPC Using UV and Refractive Index Plgel Mixed-D 79911GP-MXD
Polyethylene: Separation of GPC ZORBAX PSM Bimodal Set 880957-814
Polymethacrylate - GPC Separation ZORBAX Bimodal S 880957-814
Polystyrene, Differently Processed: GPC Analysis Plgel Mixed B 79911GP-MXB
Polyurethane Resins ZORBAX PSM 60S 880957802
Procainamides and Metabolites Separated at High pH Asahipak ODB-50 79923OP-584
Proteins: Basic Proteins Separated Using Ion Exchange Synchropak S300 79919SP-754
Proteins: Calibration of Standard Proteins GF-250 GF-250 884973-901
Proteins: Effect of Bonded Phase Zorbax 300 SB-C18
Zorbax 300 SB-C8
Zorbax 300 SB-C3
Zorbax 300 SB-CN
883995-902
883995-906
883995-909
883995-905
Proteins: Effect of Bonded Phase Zorbax 300 SB-C8
Zorbax 300 SB-CN
883995-906
883995-905
Proteins: Effect of Flow Rate Zorbax GF-250 884973-901
Proteins: HIC on TSK Phenyl Column TSK Phenyl 5PW 79912PH-147
Proteins: Ion Exchange Separation of Commercial Ovalbumin Synchropak AX300 79919DE-75
Proteins: Isolation of Aspartate Aminotransferase PL 1000 SAX 79931QA-835
Proteins: SEC Characteristics Elution Profiles of Basic and Hydrophobic Proteins ZORBAX GF-250 884973-901
Proteins: SEC of Protein Standards TSK 3000SW 79912S3-197
Proteins: Separation by SEC ZORBAX GF-250 884973-901
Proteins: Separation Using Synchropak CM 300 Column Mixture Synchropak CM300 79919CM-754
Separation of Basic Peptides on Bonus-RP vs. Traditional Alkyl Phase Bonus-RP 883668-901
USP Method: Glyburide and Internal Standard, Progesterone ZORBAX Eclipse XDB-C8 990967-906
Steroids ZORBAX Eclipse XDB-Phenyl
ZORBAX Eclipse XDB-C18
963967-912
993967-902
Tetracyclines Hypersil BDS-C18 79926BD-363
Tetracyclines ZORBAX Rx-C8 883967-901
Tricyclic Antidepressants ZORBAX Eclipse XDB-C8 993967-906
Tricyclic Antidepressants and Metabolites: Effect of Pore Size ZORBAX SB-C18
ZORBAX 300SB-C18
863953-902
883995-902
Tricyclic Antidepressants, Screening Application at High pH Asahipak ODP-50 79923OP-584
Triton X-114: Decreasing Run-Time by Changing Bonded Phase ZORBAX SB-C3
ZORBAX SB-C18
883975-909
883975-902
USP Method: Triamcino and Internal Standard, Hydrocortisone ZORBAX Rx-C18
ZORBAX SB-C18
880975-902
880967-902
Ulcer Treatment Drugs at Intermediate pH ZORBAX Bonus-RP 883668-901
Urine, LSD Analysis by LC/MS ZORBAX Eclipse XDB-C8 960967-906