ZORBAX Reversed Phase HPLC Columns
ZORBAX Bonus-RP
Agilent ZORBAX Bonus-RP columns provide unique selectivity and applicability for mid pHs with its embedded amide linkage in a C14-alkyl chain. At pH 7, Bonus-RP provides excellent peak shape even for the most challenging basic compounds.. Bonus-RP is protected from hydrolysis at low pH using the same sterically protecting bulky side chains as StableBond, and also is triple-endcapped to minimize silanol interactions and improve stability at mid-pH. Bonus-RP can be used with 100% aqueous mobile phase.
Applications: pharmaceuticals (basic, acidic, and neutral compounds), peptides separted at mid pH
pH range: Recommended 3 to 8, maximum 2 to 9
Triple-endcapped Temperature limit: 60 °C
Support Particle: Available in 3.5 and 5 mm particle sizes
|
|
Product Tables |
|
Bonus-RP |
|
|
|
ZORBAX Rx-SIL
Made from highly pure (>99.995%) porous silica microspheres (pore size is the space between the solid silica microparticles. Low acidity and low metal content make ZORBAX Rx-SIL ideal for normal-phase separation of polar compounds that exhibit poor peak symmetry on more acidic silica. Useful for very hydrophilic compounds with high organic mobile phases in reversed phase mode.
Pore Size: 80A
Surface Area: 180 m2/g
Support Particle: Available in 5 and 7 mm particle sizes
|
|
Product Tables |
|
ZORBAX Rx-SIL |
|
ZORBAX NH2
Used for normal phase and weak anion-exchange, and reversed-phase HPLC of polar compounds. Propyl-amino silane phase bonded to ZORBAX SIL.
Application: Normal Phase - Vitamins A and D; Reversed-Phase - carbohydrates and sugars
Pore Size: 70A
Surface Area: 300 m2/g
Support Particle: Available in 5 and 7mm particle sizes
|
|
Product Tables |
|
ZORBAX NH2 |
|
ZORBAX StableBond
StableBond phases were developed for use with acidic mobile phases for robust, reproducible results at low pH. StableBond offers two additional tools to improve resolution: a variety of stable bonded phase chemistries and expanded temperature ranges. Manufactured from ultrapure strong ZORBAX RX-SIL particles, StableBond columns are ideal for separating acidic, neutral and basic compounds at low pH. Unique monofunctional silanes with bulky diisobutyl (C18) or diisopropyl (with C8, C3, phenyl, CN) side-chain groups sterically protect the siloxane bond from hydrolytic attack at low pH. The result is improved resolution, high column-to-column reproducibility, long column life and superb chromatography.
Applications: pharmaceuticals, proteins, peptides, agricultural chemicals, vitamins separated at low pH
pH range: SB-C18, 1.0 to 8.0, other StableBond phases, 1.8 to 8.0
Non-endcapped
Temperature limits: SB-C18, to 90 °C, other StableBond phases, to 80 °C
Support Particle: Available in 3.5, 5, and 7 mm particle size; 80 Å and 300 Å pore size
|
|
Product Tables |
|
|
|
80 SB-C18 |
|
80 SB-C8 |
|
80 SB-CN |
|
80 SB-C3 |
|
80 SB-Phenyl |
|
300 SB-C18 |
|
300 SB-C8 |
|
300 SB-CN |
|
300 SB-C3 |
|
StableBond-AQ
The ZORBAX SB-AQ provides longer retention for many polar products - more retention than many conventiaonal ODS HPLC columns and more retention than columns that claim aqueous compatibility. The SB-AQ column is just what it's name implies, exceptionally stable in low pH aqueous mobile phases. Long-term durability and reproducibility are ensured, even for the most challenging samples, because the bonded-phase is based upon the ZORBAX StableBond technology.
Applications:acidic and basic polar compounds
Support Particle: Available in 5 mm particle size; 80 Å and 300 Å pore size
|
|
Product Tables |
|
|
|
StableBond-AQ |
|
ZORBAX Eclipse XDB
Eclipse XDB columns feature eXtra Dense Bonding, a combination of dense monolayer bonding coupled with proprietary double endcapping on robust, high purity ZORBAX Rx-SIL porous silica microspheres. This minimizes unwanted interactions between analytes and surface silanols of the silica particle, providing symmetrical peak shapes for many polar and ionizable analytes including basic compounds. The silica based particles resist dissolution at mid-pH for increased column stability.
Applications: pharmaceuticals (basic, acidic, and neutral compounds) separated at mid pH
pH range: recommended 3 to 8, maximum 2 to 9
Proprietary Double Endcapping
Temperature limit: 40°C ; maximum 60 °C
Support Particle: Available in 3.5 and 5 mm particle sizes; 80 Å pore size
|
|
Product Tables |
|
Eclipse XDB-C18 |
|
Eclipse XDB-C8 |
|
Eclipse XDB-Phenyl |
|
ZORBAX Rx
ZORBAX Rx columns are used to analyze basic compounds at low pH. Based on ultrapure ZORBAX Rx silica microspheres, Rx columns yield excellent peak symmetry and reduce peak tailing for polar basic compounds. ZORBAX Rx-C18 columns are made with a monofunctional dimethyloctadecyl silane, giving a higher carbon load than StableBond C18 columns (12% vs. 10%). Rx-C8 is equivalent to StableBond C8.
Applications: antihistamines, antidepressants, antibiotics, opiates
pH range: Rx-C8: 2.0 to 8.0; Rx-C18: 1.0 to 8.0
Non-endcapped Temperature limit: 60 °C
Support Particle: Available in 5 and 7 mm particle sizes; 80 Å pore size
|
|
Product Tables |
|
Rx-C18 |
|
Rx-C8 |
|
ZORBAX Original
The first analytical HPLC column family built on the patented ZORBAX porous silica microsphere, ZORBAX Original RP columns have been time tested to provide exceptional reproducibility and durability. These columns use the original ZORBAX SIL support, monolayer silane bonding, and single endcapping for maximum deactivation of silanol groups. Agilent Technologies' continues to manufacture a reproducible and reliable supply of these materials to support the many successful methods that have been developed on ZORBAX Original RP columns.
Applications: oil soluble vitamins, steroids
pH range: 2.0 to 8.0 Single endcapping reagent
Temperature limits: 60 °C
Support Particle: Available in 5 and 7 mm particle sizes, 70 Å pore size
|
|
Product Tables |
|
Original C18 |
|
Original C8 |
|
Original CN |
|
Original Phenyl |
|
Original TMS |
|
ZORBAX CombiHT
CombiHT columns are packed with 5 micron particles in short lengths (21.2 x 50, 21.2 x 100 and 21.2 x 150 mm), providing rapid separations in the 15-50 mg range. Separations on the 50 mm column are often less than 10 minutes. Unique hardware providing finger-tight connections up to 7,000 psi are used for CombiHT columns. End-fittings are reusable and only the column barrel is replaced. Columns are available with StableBond C18 and C8, and Eclipse XDB C18 and C8 packings, providing low bleed and extended column lifetime in the low pH and mid-range pH respectively. .
|
|
Product Tables |
|
CombiHT |
|
ZORBAX Extend-C18
Agilent ZORBAX Extend-C18 columns are the newest additions to our product porfolio, and incorporate a unique patented bidentate silane, combined with a double endcapping process to protect the silica from hydrolysis at high pH - up to pH 11.5. Extend-C18 columns are best applied for separation of compounds that are: (1) basic and have little or no retention at low or middle pHs, (2) more stalbe or soluble at high pH, or (3) basic and show poor peak shape at low or intermediate pH. Extend columns are excellent for separating basic compounds in their free base form and peptides with a clean LC/MS signal.
Applications: Basic compounds at high pH, peptide separations with clean MS, compounds soluble or stable only at high pH
pH range: Recommended pH 8 to 11.5, complete range pH 2-11.5
Triple endcapping Temperature limits: 60 °C
Support Particle: Available in 3.5 and 5 mm particle sizes, 70 Å pore size
|
|
Product Tables |
|
Extend-C18 |
|
Other Reversed Phase HPLC columns
In addition to ZORBAX brand HPLC columns, Agilent packs columns with a variety of excellent reversed phase sorbents from other manufacturers. These packings have been carefully evaluated by Agilent to meet rigorous quality assurance standards. Agilent's automated and optimized column packing stations and ISO-regulated procedures guarantee high reproducibility of these columns.
Agilent offers selected HPLC columns from other column manufacturers. This very complete line of HPLC columns means that Agilent has the right packing material with the right selectivity for your separation.
Hypersil
Hypersil BDS is both base deactivated and endcapped to improve peak shapes of basic solutes by minimizing interaction with unreacted silanols. Hypersil ODS, a very popular packing, adds a monolayer of octadecyl silane (C18) to the Hypersil Silica support. The columns are endcapped to reduce silanol interaction. For less retention with similar selectivity, Hypersil MOS columns provide a monolayer of dimethyloctylsilane (C8 alkyl chain).
Agilent's Hypersil columns are offered in standard compression fitting columns and in Agilent's convenient and economical cartridge design.
Applications:
BDS - basic drugs, explosives, antibiotics
ODS - nonpolars, lipophilic compounds
Support Particle: Available in 3 and 5 mm particle sizes; pore sizes 120 Å (ODS, MOS), 130 Å (BDS)
|
|
Product Tables |
|
BDS C18 |
|
C18 |
|
C8 |
|
LiChrospher
LiChrospher silica columns are made with spherical, 'sil' type porous silica particles. LiChrospher 60RP-select B starts with 60 Å pore size silica optimized for symmetrical peak shapes of basic compounds. LiChrospher 100 is offered in both C8 and C18 as well as an endcapped C18. These columns are noted for high sample capacity and efficiency. The popular LiChrospher packings are available in Agilent's convenient and economical cartridge configuration.
Applications: pharmaceuticals, aromatics
Support Particle: Available in 5 mm particle size
|
|
Product Tables |
|
C18 |
|
C8 |
|
LiChrosorb
LiChrosorb is a widely used silica packing material manufactured by E. Merck. The irregularly shaped porous silica particles are made by grinding and sifting coarse silica particles into narrow particle size ranges. Agilent offers Lichrosorb columns in C8 and C18 phases, in both 5 and 10 mm particle sizes. These standard fitting columns are packed by Agilent using ISO-regulated, automated packing procedures to ensure high column-to-column reproducibility.
Applications: adsorption, normal phase, reversed phase chromatography
Support Particle: granular, irregular shaped silica microparticles.
Particle Size: Available in 5 and 10 mm particle sizes
|
|
Product Tables |
|
C8, C18 |
|
Inertsil ODS-2
Intersil ODS-2 is manufactured by GL Science. Starting from the purest reagents, the silica is manufactured, bonded with C-18 and endcapped. Intersil ODS-2 meets rigid quality control tests and is well suited for a wide range of applications, including basic drugs, amines and other challenging samples.
Applications: Basic drugs, amines
Pore Size: 150A
Support Particle: Available in 5 mm particle sizes
|
|
Product Tables |
|
Inertsil ODS-2 |
|
Nucleosil
Nucleosil is a spherical porous 'sil' type silica packing material from Machery/Nagel. Agilent packs Nucleosil columns using tight ISO-regulated production control procedures to guarantee consistent quality. Nucleosil 100-5, C18 is used for nonpolar to moderately polar compounds in reversed phase applications.
Applications: fatty acids, glycerides, fat soluble vitamins, antibiotics
Support Particle: Available in 5 mm particle size, 100 Å pore size
|
|
Product Tables |
|
C18 |
|
Asahipak
Asahipak ODP-50 is a microparticulate, macroporous polyvinylalcohol based polymeric packing. Designed for analysis of basic substances, Asahipak ODP-50 columns provide high separation efficiency with buffered and alkaline solutions at high pH. These polymeric columns can be used at pH 13 with a variety of solvents with minimal mechanical swelling or shrinkage. Asahipak ODP-50 is offered in Agilent's convenient cartridge column configuration.
Applications: basic compounds
Support Particle: Available in 5 mm particle size, 80 Å pore size
|
|
Product Tables |
|
C18 |
|
Purospher
An ultrapure spherical silica support, deactivated by an efficient bonding process, makes Purospher an excellent packing for basic compounds. Multistep bonding and deactivating processes provide high surface coverage, blocking residual silanol groups and reducing peak tailing.
Applications: basic compounds, metal sensitive compounds
Support Particle: Available in 5 mm particle size, 80 Å pore size
|
|
Product Tables |
|
C18 |
|
Superspher
Supersphere is a high performance 4 mm silica support. It offers excellent pressure/performance ratio for analysis of complex mixtures demanding high peak capacity.
Applications: adsorption, normal phase, reversed phase chromatography
Support Particle: Available in 4 mm particle size
|
|
Product Tables |
|
C8 |
|
C18 |
|
Synchropak
Synchropak columns are specifically designed for high performance separations of large biomolecules such as proteins and peptides. The support is a sperical silica with a 300 Å pore and 6.54 mm particle size.
Applications: reversed phase chromatography of large biomolecules such as proteins and peptides
pH range: 2.0 to 8.0 Temperature limits: 60 °C
Support Particle: Available in 6.5 mm particle size, 300 Å pore size
|
|
Product Tables |
|
C4, C8, C18 |
|
Chiral HPLC Columns
ChiraDex
Novel manufacturing process bonds B-cyclodextrin to spherical 5um silica gel by means of a chemical spacer. Enantiomeric separations have been achieved with ChiraDex using simple nonchiral solvent systems.
Application: Barbiturates, benzothioadiazines, calcium antagonists, PTH-amino acids
Support Particle: 5mm particle sizes
|
|
Product Tables |
|
ChiraDex |
|
Ultron Chiral
Separate enantiomers of pharmacuticals, such as hexobarbital, ibuprofen and profenamine, are complete with Ultron ES-OVM. Ultron ES-Pepsin Chiral columns are best suited to separate basic compounds that are difficult to separate by other columns.
Application: ES-OVM: enantiomers of fluoxetine, chlorpheniramine, cloperastin
pH Range: ES-OVM 3-7.5; ES-Pepsin 3-6
Pore Size: 120A
Support Particle: 5mm particle size
|
|
Product Tables |
|
|
|
ES-OVM |
|
ES-Pepsin |
|
Size Exclusion Columns
ZORBAX GF-250 and GF-450
Rapid separations and extended column lifetime - often twice that of other size exclusion columns. High recovery for most proteins (>90%). Silica surface is stabilized with zirconia, then coated with a monolayer diol phase providing a broad pH range of 3-8.5, a highly reproducible, hydrophilic column.
Application: GF-250 - proteins 4,000 to 400,000 Dalton; GF-450 - proteins 10,000 to 1,000,000 Dalton
pH Range: 3 to 8.5
Support Particle: Available in 4 and 6mm
Pore Size: GF-250 - 150A; GF-450 - 300A
|
|
Product Tables |
|
ZORBAX GF-250 and GF-450 |
|
TSK Gel Filtration
Silica based TSK SW and SW-XL columns are a popular choice for gel filtration chromatography. The small particle size (5 um) of TSK SW-XL columns results in fast analyses without compromising resolution.
Application: Polysaccharides, peptides, proteins
pH Range: 2 to 7.5
Support Particle: Available in 5, 10 and 13
mm
|
|
Product Tables |
|
TSK Gel Filtration |
|
|
|
Special Applications
ZORBAX Carbohydrate Analysis
Reproducible - each lot of this applications specific aminopropyl column packing material is use-tested for specific monosaccharide and disaccharide separations. Efficient - uses ZORBAX porous silica microsphere technology. Flexible - can handle high volume injections - as much as 50 ul on a 4.6 x 150mm column.
pH Range: 2 to 8.0
Pore Size: 70A
Support Particle: Available in 5
mm
|
|
Product Tables |
|
ZORBAX Carbohydrate Analysis |
|
ZORBAX Eclipse Amino Acid Analysis
ZORBAX Eclipse AAA utilizes the technologies of eXtra-Dense Bonding (XDB) to protect the ultra-pure (Type B) silica support from dissolution in mobile phases of intermediate and higher pH. Eclipse AAA is specially prepared using ultra-high purity (>99.995% SiO2), ZORBAX Rx-SIL porous silica support. Columns are packed to a stable, uniform bed density using a proprietary, high-pressure slurry-loading technique to give maximum column efficiency.
Application: Amino Acid Analysis protocol
pH Range: 7.8
Pore Size: 80A
Support Particle: Available in 3.5 and 5
mm
|
|
Product Tables |
|
ZORBAX Eclipse AAA |
|
|
|
Normal Phase
LiChrospher
For normal phase chromatography, Agilent supplies polar modified silica gel phases LiChrospher Si, LiChrospher NH2, LiChrosper DIOL and LiChrospher CN as convenient cartridge columns.
|
|
Product Tables |
|
LiChrospher CN |
|
LiChrospher DIOL |
|
LiChrospher NH2 |
|
LiChrospher Si |
ZORBAX CN
Equilibrates more rapidly than ZORBAX Rx-SIL, and is used for many of the same normal-phase applications. Less prone to fouling than silica.
Pore Size: 70A
Surface Area: 300 m2/g
Support Particle: Available in 5 and 7mm particle sizes
|
|
Product Tables |
|
ZORBAX CN |
|
ZORBAX NH2
Used for normal phase and weak anion-exchange, and reversed-phase HPLC of polar compounds. Propyl-amino silane phase bonded to ZORBAX SIL.
Application: Normal Phase - Vitamins A and D; Reversed-Phase - carbohydrates and sugars
Pore Size: 70A
Surface Area: 300 m2/g
Support Particle: Available in 5 and 7mm particle sizes
|
|
Product Tables |
|
ZORBAX NH2 |
|
Hypersil
Hypersil silica columns from Agilent combine a strong, high-purity silica and Agilent's superior packing processes. The strength and reproducibility of these silica particles are also available in an amino phase, Hypersil APS, for normal phase chromatography.
|
|
Product Tables |
|
Hypersil |
|
Hypersil APS |
|
|
|
|
|
HPLC Columns for DNA Separations
ZORBAX Eclipse dsDNA
Optimized for HPLC separations of dsDNA fragments in the 20-1500 bp range. Provide high resolution - as little as 1 bp depending on time and fragment size.
Application: PCR fragments, DHPLC, RAPD, Restriction digests, RFLP
pH Range: 2 to 9.0
Support Particle: Available in 3.5
mm particle sizes
|
|
Product Tables |
|
ZORBAX Eclipse dsDNA |
|
ZORBAX Bio Series Oligo
Mixed mode ion exchange and reversed phase columns specifically developed for oligonucleotide purification. Unique ligand is bonded to 5um, 150A silica that has been stabilized with zirconium oxide. Denaturants can be used to prevent self-hybridization.
Application: Heterodeoxyoligonucleotides, purification of oligonucleotides
pH Range: 2.5 to 8.5
Pore Size: 150A
Support Particle: Available in 5
mm
|
|
Product Tables |
|
ZORBAX Bio Series Oligo |
|
|
|
Ion Exchange Columns
ZORBAX PSM, SAX, and SCX
ZORBAX Bio Series Ion Exchange columns (300A SAX and 300A SCX) use a zirconium oxide-stabilized silica as the stationary phase support; ion exchange groups are attached to a diol backbone.
|
|
Product Tables |
|
ZORBAX SAX |
|
ZORBAX SCX |
|
TSK Non-Porous Columns
TSK Nonporous resin columns offer a high spped, high recovery, high sensitivity alternative to conventional porous HPLC columns for macromolecule separations.
|
|
Product Tables |
|
TSK Non-Porous |
|
|