/* SiteCatalyst code version: H.21.

REVISIONS:
09-26-2007
  - Changed report suite value to "agilentfrontierdev"
01-23-2008
  - Removed "." from s.linkInternalFilters & added "chem.agilent.com"
  - Updated to version H.14 code
  - Added Frontier library search term tracking
  - Added s.apl plugin
01-26-2008
  - Added Dynamic Account Selection
01-29-2008
  - Updated downloadLinkHandler logic
04-18-2008
  - Moved s.prop17 below s.campaign to fix getCustomPagePath
09-4-2008
  - Product Views, Cart Opens, Cart Views, Cart Checkouts, Purchases
  - Internal Searches
  - Product Group
  - Library Searches
  - Country-Language
11-7-2008
  - Product Detail Page SKU
  - Hourly Visits
11-18-2008
  - Fixed "event4"
03-05-2009
  - Fixed Campaign (CID) Pathing report issue
05-08-2009
  - Library Search Fixes (all search options)
  - Logged in/out
  - additional internal search parameters
07-14-2009
  - combined product and industry library search parameters
  - fixed 404 tracking
  - video views
09-21-2009
  - Google search ranking
17-02-2010
  - Page scraping code added to set event 15 on thank you page of request a quote
23-03-2010
  - Page Name copied to eVar13
5-Apr-2010
  - Added code to choose report suite based on domain and removed dynamic accounts code
  - Upgraded to H.21
  - fixed reference to pageName to s.pageName
  - added if statement to check URL for requestquote.aspx to make sure request a quote only happening on these pages
6-Apr-2010
  - added page scraping code to check if the user is logged in or not.
7-Apr-2010
  - added docx, xslx, ppt, and pptx file extensions
  
  
Copyright 1997-2007 Omniture, Inc. More info available at
http://www.omniture.com */
/************************ ADDITIONAL FEATURES ************************
     Plugins
*/
/* Specify the Report Suite ID(s) to track here */
var URL = location.href;
var s_account="test"
if(URL.indexOf('www.chem.agilent.com') > -1 || URL.indexOf('extranet.chem.agilent.com') > -1 || URL.indexOf('intranet.chem.agilent.com') > -1){
    s_account = 'agilentfrontierprod';
}else if(URL.indexOf('stgwww.cos.agilent.com') > -1 || URL.indexOf('stgextranetb.cos.agilent.com') > -1){
    s_account = 'agilentfrontierdev';
}else if(URL.indexOf('testwww.cos.agilent.com') > -1 || URL.indexOf('Testextranet.cos.agilent.com') > -1){
    s_account = 'agilentfrontiertest';
}
var s=s_gi(s_account)

/************************** CONFIG SECTION **************************/
/* You may add or alter any code config here. */

/* Link Tracking Config */
s.trackDownloadLinks=true
s.trackExternalLinks=true
s.trackInlineStats=true
s.linkDownloadFileTypes="exe,zip,wav,mp3,mov,mpg,avi,wmv,doc,pdf,xls,docx,xslx,ppt,pptx"
s.linkInternalFilters="javascript:,chem.agilent.com"
s.linkLeaveQueryString=false
s.linkTrackVars="None"
s.linkTrackEvents="None"

/* Page Name Plugin Config */
s.siteID=""         // leftmost value in pagename
s.defaultPage="index"   // filename to add when none exists
s.queryVarsList=""   	// query parameters to keep
s.pathExcludeDelim=";"	// portion of the path to exclude
s.pathConcatDelim=":"   // page name component separator
s.pathExcludeList=""	// elements to exclude from the path

/* DynamicObjectIDs config */
function s_getObjectID(o){
	var ID=o.href;
	return ID;
}
s.getObjectID=s_getObjectID

/* Plugin Config */
s.usePlugins=true
function s_doPlugins(s) {
	// set up dynamic object IDs for ClickMap
	s.setupDynamicObjectIDs();

	/* Pageview event - Track pageviews for conversion reporting */
	s.events=s.apl(s.events,'event12',',',2);
	
	/* Google search ranking */
	if(document.referrer&&document.referrer.indexOf('google.com')>-1){
		s.prop36=s.getQueryParam('cd','',document.referrer);
	}

	/* URL - Track current URL */
	s.prop1=location.href;
	s.prop1=s.prop1.toLowerCase();

	/* getQueryParam v2.1 - Captures the tracking code */
	s.campaign=s.getQueryParam('cid');

	/* Plugin Example: getPagename v2.1 */
	if(!s.pageType && !s.pageName) {
		s.pageName=s.getPageName();
		s.pageName=s.pageName.toLowerCase();
	}
	s.prevPage=s.getPreviousValue(s.pageName,'gpv_p9');
	
	var campPath=s.campaign?s.campaign:s.c_r('campPath');
	if(campPath){
		s.prop17="CID "+campPath+":"+s.pageName;
		s.c_w('campPath',campPath);
	}

	/* channelExtract - Gets the site hierarchy */
	if(!s.channel) s.channel=s.channelExtract(":",2,s.pageName);
		s.channel=s.channel.toLowerCase();
	if(!s.prop2) s.prop2=s.channelExtract(":",3,s.pageName);
		s.prop2=s.prop2.toLowerCase();
	if(!s.prop3) s.prop3=s.channelExtract(":",4,s.pageName);
		s.prop3=s.prop3.toLowerCase();
	if(!s.prop4) s.prop4=s.channelExtract(":",5,s.pageName);
		s.prop4=s.prop4.toLowerCase();
	if(!s.hier1) s.hier1=s.channelExtract(":",10,s.pageName,1);
		s.hier1=s.hier1.toLowerCase();

	/* Language */
	s.prop24=s.channelExtract(":",1,s.pageName);
	if(s.prop24.indexOf('-')==-1){
		s.prop21=s.prop22=s.prop24='';
	}else{
		s.prop21=s.prop24.substring(0,s.prop24.indexOf('-'));
		s.prop24=s.prop24.substring(0,s.prop24.length-1);
		s.prop22=s.prop24.substring(s.prop24.indexOf('-')+1);
		
	}

	/* Product Views */
	if(s.getQueryParam('productID')){
		s.products=";"+s.getQueryParam('productID');
		s.events=s.apl(s.events,'prodView,event7',',',2);
	}

	/* Cart Adds */
	s.cartBtn=s.linkHandler("lnkBtnAddToCart");
	if(s.cartBtn){
		s.events=s.apl(s.events,'scAdd',',',2);
		s.linkTrackVars="events";
		s.linkTrackEvents="scAdd";
		s.events=s.getCartOpen("s_scOpen");
		if(s.events.indexOf('scOpen')>-1 && s.linkTrackEvents.indexOf('scAdd')>-1) s.linkTrackEvents=s.apl(s.linkTrackEvents,'scOpen',',',1);
	}

	/* Cart Views */
	if(s.linkHandler("ViewCart")){
		s.events=s.apl(s.events,'scView',',',2);
		s.linkTrackVars="events";
		s.linkTrackEvents="scView";
	}  

	/* Cart Checkouts */
	if(location.href.toLowerCase().search(/billinginfo.aspx/)>-1){
		s.events=s.apl(s.events,'scCheckout',',',2);
	}

	/* Purchases */
	if(location.href.toLowerCase().indexOf("orderconfirmation.aspx")>-1){
		s.events=s.apl(s.events,'purchase',',',2);
		s.purchaseID=document.getElementById("ctl00_PlaceHolderMain_OrderConfirmationContainer1_OrderConfirmation1_lblSaleOrderInfo").innerHTML;
		s.purchaseID=s.purchaseID.substring(12,s.purchaseID.length);
	}

	/* Product Group */
	if(s.pageName.toLowerCase().indexOf("products")>-1){
		s.prop10=s.channelExtract(":",4,s.pageName);
		s.prop10=s.prop10.substring(s.prop10.indexOf("products")+9,s.prop10.length-1);
		s.eVar12=s.prop10;
	}
	
	/* Internal Searches - not library search results */
	var tSearch, srDiv;
	if(location.href.toLowerCase().indexOf("librarysearchresults")==-1){
		s.prop7=s.getQueryParam('k');
		s.prop7=s.eVar4=s.prop7.toLowerCase();
		var tSearch=s.getValOnce(s.eVar4,"v4",0);
		if(tSearch){
			s.events=s.apl(s.events,"event5",",",2);

			// search origination
			s.prop9=s.prevPage;
			
			srDiv=document.getElementById("SRST");
			if(srDiv){
				s.prop8=srDiv.innerHTML;
				s.prop8=s.prop8.toLowerCase();
				s.prop26=s.prop8.substring(s.prop8.indexOf("took")+5,s.prop8.indexOf("seconds")-1);
				s.prop8=s.prop8.substring(s.prop8.indexOf("of")+3,s.prop8.indexOf(".&nbsp"));
				if(!s.prop8){
					s.prop8='0';
					s.prop7=s.eVar7='null:'+s.prop7;
				}
				if(s.prop8.indexOf("about")>-1){
					s.prop8=s.prop8.substring(s.prop8.indexOf("about")+6,s.prop8.length);
				}
				if(s.prop8.indexOf("<div")>-1){
					s.prop8='';
				}
			}
		}
	}

	/* Library Searches */
	if(location.href.toLowerCase().indexOf("librarysearchresults")>-1){
		s.prop14=s.getQueryParam('k');
		s.prop14=s.eVar8=s.prop14.toLowerCase();
				
		srDiv=document.getElementById("SRST");
		if(srDiv){
			s.prop15=srDiv.innerHTML;
			s.prop15=s.prop15.toLowerCase();
			s.prop26=s.prop15.substring(s.prop15.indexOf("took")+5,s.prop15.indexOf("seconds")-1);
			s.prop15=s.prop15.substring(s.prop15.indexOf("of")+3,s.prop15.indexOf(".&nbsp"));
			s.prop15=s.trim(s.prop15);
			s.prop26=s.trim(s.prop26);
			if(!s.prop15){
				s.prop15='0';
				s.prop14=s.eVar14=s.prop14?('null:'+s.prop14):'';
			}
			if(s.prop15.indexOf("about")>-1){
				s.prop15=s.prop15.substring(s.prop15.indexOf("about")+6,s.prop15.length);
			}
			if(s.prop15.indexOf("<div")>-1){
				s.prop15='';
			}
		}
		
		// additional parameters
		s.prop11=s.getSearchToken('PartNumber');
		s.prop11=s.prop11?s.prop11.toLowerCase():'';
		s.prop12=s.getSearchToken('ContentType2');
		s.prop28=s.getSearchToken('IndustryGroup');
		s.prop29=s.getSearchToken('IndustryType');
		s.prop30=s.getSearchToken('Language');
		s.prop13=s.getSearchToken('ProductGroup');
		s.prop33=s.getSearchToken('ProductType');
		s.prop34=s.getSearchToken('Product');
		// combine product fields
		if(s.prop13&&s.prop33){
			s.prop33=s.prop13+':'+s.prop33;
			if(s.prop34)s.prop34=s.prop33+':'+s.prop34;
		}
		// combine industry fields
		if(s.prop28&&s.prop29){
			s.prop29=s.prop28+':'+s.prop29;
		}
		
		if(s.prop11||s.prop12||s.prop13||s.prop14||s.prop28||s.prop29||s.prop30||s.prop33||s.prop34){
			s.events=s.apl(s.events,"event14",",",2);
		} 
	}

	/* Product Detail Page SKUs */
	if (document.URL.indexOf('ProductDetail.aspx')!=-1) {
		s.prop25=s.getQueryParam('productID');
	}

	/* Hourly Visits */
	var gtp_date=new Date();
	var gtp_hour=s.getTimeParting('h','-5',gtp_date.getFullYear()); // Set hour
	var gtp_day =s.getTimeParting('d','-5',gtp_date.getFullYear()); // Set day
	s.prop27=gtp_day+" "+gtp_hour;
	
	/* Video Views */
	if(typeof(so)!='undefined'){
		var videoParams=so.getParams();
		s.eVar10=videoParams.flashvars?s.getQueryParam('file','','http://www.chem.agilent.com/?'+videoParams.flashvars):'';
		
		s.eVar10=s.eVar10?s.repl(s.eVar10,'http://download.chem.agilent.com/videos/',''):'';
		s.eVar10=s.eVar10?s.repl(s.eVar10,'https://download.chem.agilent.com/videos/',''):'';
		if(s.eVar10) s.events=s.apl(s.events,"event13",",",2);
	}
	/* Track File Downloads - downloadLinkHandler */
	s.url=s.downloadLinkHandler();
	if(s.url){
		s.events="event4";
		s.eVar3=s.url;
		s.eVar3=s.eVar3.toLowerCase();
		s.eVar3=s.eVar3.toLowerCase();
		s.linkTrackVars="events,eVar3";
		s.linkTrackEvents="event4";
		
		if(s.url.indexOf('.wmv')>-1){
			s.events=s.apl(s.events,"event13",",",2);
			s.eVar10=s.repl(s.url,'http://www.chem.agilent.com/Library/sales/Public/','');
			s.eVar10=decodeURI(s.eVar10);
			s.linkTrackEvents=s.apl(s.linkTrackEvents,"event13",",",2);
			s.linkTrackVars=s.apl(s.linkTrackVars,"eVar10",",",2);
		}
	}
	
	/* 404 error page */
	if(location.href.indexOf('Agilent404')>-1){
		s.pageType='errorPage';
		s.pageName='404 error page';
		s.prop35=document.referrer?document.referrer:document.location;
		s.channel=s.hier1=s.prop1=s.prop2=s.prop22=s.prop24='';
	}
	
	//Scrape page for data to see if this is the request a quote thank you page
	if (document.body.innerHTML.indexOf("Agilent Life Sciences and Chemical Analysis has received and will respond, or review the quote request you submitted today.  Thank you.") > -1){
		if(s.pageName.indexOf('requestquote.aspx') > -1)
            s.events=s.apl(s.events,"event15",",",2); 
	}
	
	if(s.pageName) s.eVar13=s.pageName;
	
	//Scrape page for data to see if this user is logged in or not
	if (document.body.innerHTML.indexOf("Logout") > -1 && document.body.innerHTML.indexOf("My Profile") > -1){
		s.prop18 = "logged in"; 
	}else{
        s.prop18 = "not logged in";
    }
}
s.doPlugins=s_doPlugins
/************************** PLUGINS SECTION *************************/
s.trim=function(str){ 
	// this will get rid of leading spaces 
	str=s.repl(str,'&nbsp;','');
	while(str.substring(0,1)==' ') 
		str=str.substring(1,str.length);

	// this will get rid of trailing spaces 
	while(str.substring(str.length-1,str.length)==' ')
		str=str.substring(0,str.length-1);

	return str;
}

s.getSearchToken=function(param){
	var libraryParams=s.getQueryParam('a'), searchToken;
	libraryParams=unescape(libraryParams);
	param=param+':'
	if(libraryParams.indexOf(param)>-1){
		searchToken=libraryParams.substring(libraryParams.indexOf(param));
		if(searchToken.charAt(param.length)=='"'){
			// 2nd quote+space
			if(searchToken.indexOf('" ')==-1){
				searchToken=searchToken.substring(searchToken.indexOf('"')+1,searchToken.lastIndexOf('"'));
			}else{
				searchToken=searchToken.substring(searchToken.indexOf('"')+1,searchToken.indexOf('" '));
			}
		}else if(searchToken.indexOf(' ')>-1){
			// space only
			searchToken=searchToken.substring(searchToken.indexOf(':')+1,searchToken.indexOf(' '));
		}else{
			// end of string
			searchToken=searchToken.substring(searchToken.indexOf(':')+1);
		}
	}
	return searchToken;
}

/*
 * Plugin: getQueryParam 2.3
 */
s.getQueryParam=new Function("p","d","u",""
+"var s=this,v='',i,t;d=d?d:'';u=u?u:(s.pageURL?s.pageURL:s.wd.locati"
+"on);if(u=='f')u=s.gtfs().location;while(p){i=p.indexOf(',');i=i<0?p"
+".length:i;t=s.p_gpv(p.substring(0,i),u+'');if(t){t=t.indexOf('#')>-"
+"1?t.substring(0,t.indexOf('#')):t;}if(t)v+=v?d+t:t;p=p.substring(i="
+"=p.length?i:i+1)}return v");
s.p_gpv=new Function("k","u",""
+"var s=this,v='',i=u.indexOf('?'),q;if(k&&i>-1){q=u.substring(i+1);v"
+"=s.pt(q,'&','p_gvf',k)}return v");
s.p_gvf=new Function("t","k",""
+"if(t){var s=this,i=t.indexOf('='),p=i<0?t:t.substring(0,i),v=i<0?'T"
+"rue':t.substring(i+1);if(p.toLowerCase()==k.toLowerCase())return s."
+"epa(v)}return ''");

/*
 * Plugin: getValOnce 0.2 - get a value once per session or number of days
 */
s.getValOnce=new Function("v","c","e",""
+"var s=this,k=s.c_r(c),a=new Date;e=e?e:0;if(v){a.setTime(a.getTime("
+")+e*86400000);s.c_w(c,v,e?a:0);}return v==k?'':v");

/*
 * Plugin: getPreviousValue_v1.0 - return previous value of designated
 *   variable (requires split utility)
 */
s.getPreviousValue=new Function("v","c","el",""
+"var s=this,t=new Date,i,j,r='';t.setTime(t.getTime()+1800000);if(el"
+"){if(s.events){i=s.split(el,',');j=s.split(s.events,',');for(x in i"
+"){for(y in j){if(i[x]==j[y]){if(s.c_r(c)) r=s.c_r(c);v?s.c_w(c,v,t)"
+":s.c_w(c,'no value',t);return r}}}}}else{if(s.c_r(c)) r=s.c_r(c);v?"
+"s.c_w(c,v,t):s.c_w(c,'no value',t);return r}");

/*                                                                                        
 * Plugin: channelExtract : 1.0 - returns site section based on delimiter 
 */
s.channelExtract=new Function("d","p","u","pv",""
+"var s=this,v='';u=u?u:(s.pageURL?s.pageURL:s.wd.location);if(u=='f'"
+")u=s.gtfs().location;u=u+'';li=u.lastIndexOf(d);if(li>0){u=u.substr"
+"ing(0,li);var i,n,a=s.split(u,d),al=a.length;if(al<p){if(pv==1) p=a"
+"l;else return '';}for(i=0;i<p;i++){n=a[i];v=v+n+d;}return v}return "
+"'';");
/*
 * Plugin: getPageName v2.1 - parse URL and return
 */
s.getPageName=new Function("u",""
+"var s=this,v=u?u:''+s.wd.location,x=v.indexOf(':'),y=v.indexOf('/',"
+"x+4),z=v.indexOf('?'),c=s.pathConcatDelim,e=s.pathExcludeDelim,g=s."
+"queryVarsList,d=s.siteID,n=d?d:'',q=z<0?'':v.substring(z+1),p=v.sub"
+"string(y+1,q?z:v.length);z=p.indexOf('#');p=z<0?p:s.fl(p,z);x=e?p.i"
+"ndexOf(e):-1;p=x<0?p:s.fl(p,x);p+=!p||p.charAt(p.length-1)=='/'?s.d"
+"efaultPage:'';y=c?c:'/';while(p){x=p.indexOf('/');x=x<0?p.length:x;"
+"z=s.fl(p,x);if(!s.pt(s.pathExcludeList,',','p_c',z))n+=n?y+z:z;p=p."
+"substring(x+1)}y=c?c:'?';while(g){x=g.indexOf(',');x=x<0?g.length:x"
+";z=s.fl(g,x);z=s.pt(q,'&','p_c',z);if(z){n+=n?y+z:z;y=c?c:'&'}g=g.s"
+"ubstring(x+1)}return n");

/*
 * Plugin: Custom Page Path v1.0 
 */
s.getCustomPagePath=new Function("v","c","p",""
+"var s=this;var pn=s.pageName;r='';"
+"var t=new Date;t.setTime(t.getTime()+1800000);"
+"if(v){if(s.c_w(c,v,t)){r=p+v+':'+pn}}"
+"else{v=s.c_r(c);if(v){s.c_w(c,v,t);r=pn;}}"
+"return r;");

/*
 * Plugin: getCartOpen v 1.1 - returns events string with scOpen added
 * the first time scAdd occurs during a visit.
 */
s.getCartOpen=new Function("c",""
+"var s=this,t=new Date,e=s.events?s.events:'',i=0;t.setTime(t.getTim"
+"e()+1800000);if(s.c_r(c)||e.indexOf('scOpen')>-1){if(!s.c_w(c,1,t))"
+"{s.c_w(c,1,0)}}else{if(e.indexOf('scAdd')>-1){if(s.c_w(c,1,t)){i=1}"
+"else if(s.c_w(c,1,0)){i=1}}}if(i){e=e+',scOpen'}return e");

/*
 * DynamicObjectIDs v1.4: Setup Dynamic Object IDs based on URL
 */
s.setupDynamicObjectIDs=new Function(""
+"var s=this;if(!s.doi){s.doi=1;if(s.apv>3&&(!s.isie||!s.ismac||s.apv"
+">=5)){if(s.wd.attachEvent)s.wd.attachEvent('onload',s.setOIDs);else"
+" if(s.wd.addEventListener)s.wd.addEventListener('load',s.setOIDs,fa"
+"lse);else{s.doiol=s.wd.onload;s.wd.onload=s.setOIDs}}s.wd.s_semapho"
+"re=1}");
s.setOIDs=new Function("e",""
+"var s=s_c_il["+s._in+"],b=s.eh(s.wd,'onload'),o='onclick',x,l,u,c,i"
+",a=new Array;if(s.doiol){if(b)s[b]=s.wd[b];s.doiol(e)}if(s.d.links)"
+"{for(i=0;i<s.d.links.length;i++){l=s.d.links[i];c=l[o]?''+l[o]:'';b"
+"=s.eh(l,o);z=l[b]?''+l[b]:'';u=s.getObjectID(l);if(u&&c.indexOf('s_"
+"objectID')<0&&z.indexOf('s_objectID')<0){u=s.repl(u,'\"','');u=s.re"
+"pl(u,'\\n','').substring(0,97);l.s_oc=l[o];a[u]=a[u]?a[u]+1:1;x='';"
+"if(c.indexOf('.t(')>=0||c.indexOf('.tl(')>=0||c.indexOf('s_gs(')>=0"
+")x='var x=\".tl(\";';x+='s_objectID=\"'+u+'_'+a[u]+'\";return this."
+"s_oc?this.s_oc(e):true';if(s.isns&&s.apv>=5)l.setAttribute(o,x);l[o"
+"]=new Function('e',x)}}}s.wd.s_semaphore=0;return true");

/*
 * Plugin: getTimeParting 1.3 - Set timeparting values based on time zone
 */
s.getTimeParting=new Function("t","z","y",""
+"dc=new Date('1/1/2000');f=15;ne=8;if(dc.getDay()!=6||"
+"dc.getMonth()!=0){return'Data Not Available'}else{;z=parseInt(z);"
+"if(y=='2009'){f=8;ne=1};gmar=new Date('3/1/'+y);dsts=f-gmar.getDay("
+");gnov=new Date('11/1/'+y);dste=ne-gnov.getDay();spr=new Date('3/'"
+"+dsts+'/'+y);fl=new Date('11/'+dste+'/'+y);cd=new Date();"
+"if(cd>spr&&cd<fl){z=z+1}else{z=z};utc=cd.getTime()+(cd.getTimezoneO"
+"ffset()*60000);tz=new Date(utc + (3600000*z));thisy=tz.getFullYear("
+");var days=['Sunday','Monday','Tuesday','Wednesday','Thursday','Fr"
+"iday','Saturday'];if(thisy!=y){return'Data Not Available'}else{;thi"
+"sh=tz.getHours();thismin=tz.getMinutes();thisd=tz.getDay();var dow="
+"days[thisd];var ap='AM';var dt='Weekday';var mint='00';if(thismin>3"
+"0){mint='30'}if(thish>=12){ap='PM';thish=thish-12};if (thish==0){th"
+"ish=12};if(thisd==6||thisd==0){dt='Weekend'};var timestring=thish+'"
+":'+mint+ap;var daystring=dow;var endstring=dt;if(t=='h'){return tim"
+"estring}if(t=='d'){return daystring};if(t=='w'){return en"
+"dstring}}};"
);

/*
 * Plugin: downloadLinkHandler 0.5 - identify and report download links
 */
s.downloadLinkHandler=new Function("p",""
+"var s=this,h=s.p_gh(),n='linkDownloadFileTypes',i,t;if(!h||(s.linkT"
+"ype&&(h||s.linkName)))return '';i=h.indexOf('?');t=s[n];s[n]=p?p:t;"
+"if(s.lt(h)=='d')s.linkType='d';else h='';s[n]=t;return h;");

/*
 * Plugin: linkHandler 0.5 - identify and report custom links
 */
s.linkHandler=new Function("p","t",""
+"var s=this,h=s.p_gh(),i,l;t=t?t:'o';if(!h||(s.linkType&&(h||s.linkN"
+"ame)))return '';i=h.indexOf('?');h=s.linkLeaveQueryString||i<0?h:h."
+"substring(0,i);l=s.pt(p,'|','p_gn',h.toLowerCase());if(l){s.linkNam"
+"e=l=='[['?'':l;s.linkType=t;return h;}return '';");
s.p_gn=new Function("t","h",""
+"var i=t?t.indexOf('~'):-1,n,x;if(t&&h){n=i<0?'':t.substring(0,i);x="
+"t.substring(i+1);if(h.indexOf(x.toLowerCase())>-1)return n?n:'[[';}"
+"return 0;");

/*
 * Plugin Utility: apl v1.1
 */
s.apl=new Function("L","v","d","u",""
+"var s=this,m=0;if(!L)L='';if(u){var i,n,a=s.split(L,d);for(i=0;i<a."
+"length;i++){n=a[i];m=m||(u==1?(n==v):(n.toLowerCase()==v.toLowerCas"
+"e()));}}if(!m)L=L?L+d+v:v;return L");

/*
 * Utility Function: split v1.5 - split a string (JS 1.0 compatible)
 */
s.split=new Function("l","d",""
+"var i,x=0,a=new Array;while(l){i=l.indexOf(d);i=i>-1?i:l.length;a[x"
+"++]=l.substring(0,i);l=l.substring(i+d.length);}return a");

/*
 * Plugin Utility: Replace v1.0
 */
s.repl=new Function("x","o","n",""
+"var i=x.indexOf(o),l=n.length;while(x&&i>=0){x=x.substring(0,i)+n+x."
+"substring(i+o.length);i=x.indexOf(o,i+l)}return x");

/*
 * Utility Function: p_c
 */
s.p_c=new Function("v","c",""
+"var x=v.indexOf('=');return c.toLowerCase()==v.substring(0,x<0?v.le"
+"ngth:x).toLowerCase()?v:0");

/*
 * Utility Function: p_gh
 */
s.p_gh=new Function(""
+"var s=this;if(!s.eo&&!s.lnk)return '';var o=s.eo?s.eo:s.lnk,y=s.ot("
+"o),n=s.oid(o),x=o.s_oidt;if(s.eo&&o==s.eo){while(o&&!n&&y!='BODY'){"
+"o=o.parentElement?o.parentElement:o.parentNode;if(!o)return '';y=s."
+"ot(o);n=s.oid(o);x=o.s_oidt}}return o.href?o.href:'';");

/*
 * Function - read combined cookies v 0.3
 */
if(!s.__ccucr){s.c_rr=s.c_r;s.__ccucr = true;
s.c_r=new Function("k",""
+"var s=this,d=new Date,v=s.c_rr(k),c=s.c_rr('s_pers'),i,m,e;if(v)ret"
+"urn v;k=s.ape(k);i=c.indexOf(' '+k+'=');c=i<0?s.c_rr('s_sess'):c;i="
+"c.indexOf(' '+k+'=');m=i<0?i:c.indexOf('|',i);e=i<0?i:c.indexOf(';'"
+",i);m=m>0?m:e;v=i<0?'':s.epa(c.substring(i+2+k.length,m<0?c.length:"
+"m));if(m>0&&m!=e)if(parseInt(c.substring(m+1,e<0?c.length:e))<d.get"
+"Time()){d.setTime(d.getTime()-60000);s.c_w(s.epa(k),'',d);v='';}ret"
+"urn v;");}
/*
 * Function - write combined cookies v 0.3
 */
if(!s.__ccucw){s.c_wr=s.c_w;s.__ccucw = true;
s.c_w=new Function("k","v","e",""
+"this.new2 = true;"
+"var s=this,d=new Date,ht=0,pn='s_pers',sn='s_sess',pc=0,sc=0,pv,sv,"
+"c,i,t;d.setTime(d.getTime()-60000);if(s.c_rr(k)) s.c_wr(k,'',d);k=s"
+".ape(k);pv=s.c_rr(pn);i=pv.indexOf(' '+k+'=');if(i>-1){pv=pv.substr"
+"ing(0,i)+pv.substring(pv.indexOf(';',i)+1);pc=1;}sv=s.c_rr(sn);i=sv"
+".indexOf(' '+k+'=');if(i>-1){sv=sv.substring(0,i)+sv.substring(sv.i"
+"ndexOf(';',i)+1);sc=1;}d=new Date;if(e){if(e.getTime()>d.getTime())"
+"{pv+=' '+k+'='+s.ape(v)+'|'+e.getTime()+';';pc=1;}}else{sv+=' '+k+'"
+"='+s.ape(v)+';';sc=1;}if(sc) s.c_wr(sn,sv,0);if(pc){t=pv;while(t&&t"
+".indexOf(';')!=-1){var t1=parseInt(t.substring(t.indexOf('|')+1,t.i"
+"ndexOf(';')));t=t.substring(t.indexOf(';')+1);ht=ht<t1?t1:ht;}d.set"
+"Time(ht);s.c_wr(pn,pv,d);}return v==s.c_r(s.epa(k));");}

/* WARNING: Changing any of the below variables will cause drastic
changes to how your visitor data is collected.  Changes should only be
made when instructed to do so by your account manager.*/
s.visitorNamespace='agilentlsca';
s.dc=112

/************* DO NOT ALTER ANYTHING BELOW THIS LINE ! **************/
var s_code='',s_objectID;function s_gi(un,pg,ss){var c="s._c='s_c';s.wd=window;if(!s.wd.s_c_in){s.wd.s_c_il=new Array;s.wd.s_c_in=0;}s._il=s.wd.s_c_il;s._in=s.wd.s_c_in;s._il[s._in]=s;s.wd.s_c_in++;s"
+".an=s_an;s.cls=function(x,c){var i,y='';if(!c)c=this.an;for(i=0;i<x.length;i++){n=x.substring(i,i+1);if(c.indexOf(n)>=0)y+=n}return y};s.fl=function(x,l){return x?(''+x).substring(0,l):x};s.co=func"
+"tion(o){if(!o)return o;var n=new Object,x;for(x in o)if(x.indexOf('select')<0&&x.indexOf('filter')<0)n[x]=o[x];return n};s.num=function(x){x=''+x;for(var p=0;p<x.length;p++)if(('0123456789').indexO"
+"f(x.substring(p,p+1))<0)return 0;return 1};s.rep=s_rep;s.sp=s_sp;s.jn=s_jn;s.ape=function(x){var s=this,h='0123456789ABCDEF',i,c=s.charSet,n,l,e,y='';c=c?c.toUpperCase():'';if(x){x=''+x;if(c=='AUTO"
+"'&&('').charCodeAt){for(i=0;i<x.length;i++){c=x.substring(i,i+1);n=x.charCodeAt(i);if(n>127){l=0;e='';while(n||l<4){e=h.substring(n%16,n%16+1)+e;n=(n-n%16)/16;l++}y+='%u'+e}else if(c=='+')y+='%2B';"
+"else y+=escape(c)}x=y}else{x=x?s.rep(escape(''+x),'+','%2B'):x;if(x&&c&&s.em==1&&x.indexOf('%u')<0&&x.indexOf('%U')<0){i=x.indexOf('%');while(i>=0){i++;if(h.substring(8).indexOf(x.substring(i,i+1)."
+"toUpperCase())>=0)return x.substring(0,i)+'u00'+x.substring(i);i=x.indexOf('%',i)}}}}return x};s.epa=function(x){var s=this;return x?unescape(s.rep(''+x,'+',' ')):x};s.pt=function(x,d,f,a){var s=th"
+"is,t=x,z=0,y,r;while(t){y=t.indexOf(d);y=y<0?t.length:y;t=t.substring(0,y);r=s[f](t,a);if(r)return r;z+=y+d.length;t=x.substring(z,x.length);t=z<x.length?t:''}return ''};s.isf=function(t,a){var c=a"
+".indexOf(':');if(c>=0)a=a.substring(0,c);if(t.substring(0,2)=='s_')t=t.substring(2);return (t!=''&&t==a)};s.fsf=function(t,a){var s=this;if(s.pt(a,',','isf',t))s.fsg+=(s.fsg!=''?',':'')+t;return 0}"
+";s.fs=function(x,f){var s=this;s.fsg='';s.pt(x,',','fsf',f);return s.fsg};s.si=function(){var s=this,i,k,v,c=s_gi+'var s=s_gi(\"'+s.oun+'\");s.sa(\"'+s.un+'\");';for(i=0;i<s.va_g.length;i++){k=s.va"
+"_g[i];v=s[k];if(v!=undefined){if(typeof(v)=='string')c+='s.'+k+'=\"'+s_fe(v)+'\";';else c+='s.'+k+'='+v+';'}}c+=\"s.lnk=s.eo=s.linkName=s.linkType=s.wd.s_objectID=s.ppu=s.pe=s.pev1=s.pev2=s.pev3=''"
+";\";return c};s.c_d='';s.c_gdf=function(t,a){var s=this;if(!s.num(t))return 1;return 0};s.c_gd=function(){var s=this,d=s.wd.location.hostname,n=s.fpCookieDomainPeriods,p;if(!n)n=s.cookieDomainPerio"
+"ds;if(d&&!s.c_d){n=n?parseInt(n):2;n=n>2?n:2;p=d.lastIndexOf('.');if(p>=0){while(p>=0&&n>1){p=d.lastIndexOf('.',p-1);n--}s.c_d=p>0&&s.pt(d,'.','c_gdf',0)?d.substring(p):d}}return s.c_d};s.c_r=funct"
+"ion(k){var s=this;k=s.ape(k);var c=' '+s.d.cookie,i=c.indexOf(' '+k+'='),e=i<0?i:c.indexOf(';',i),v=i<0?'':s.epa(c.substring(i+2+k.length,e<0?c.length:e));return v!='[[B]]'?v:''};s.c_w=function(k,v"
+",e){var s=this,d=s.c_gd(),l=s.cookieLifetime,t;v=''+v;l=l?(''+l).toUpperCase():'';if(e&&l!='SESSION'&&l!='NONE'){t=(v!=''?parseInt(l?l:0):-60);if(t){e=new Date;e.setTime(e.getTime()+(t*1000))}}if(k"
+"&&l!='NONE'){s.d.cookie=k+'='+s.ape(v!=''?v:'[[B]]')+'; path=/;'+(e&&l!='SESSION'?' expires='+e.toGMTString()+';':'')+(d?' domain='+d+';':'');return s.c_r(k)==v}return 0};s.eh=function(o,e,r,f){var"
+" s=this,b='s_'+e+'_'+s._in,n=-1,l,i,x;if(!s.ehl)s.ehl=new Array;l=s.ehl;for(i=0;i<l.length&&n<0;i++){if(l[i].o==o&&l[i].e==e)n=i}if(n<0){n=i;l[n]=new Object}x=l[n];x.o=o;x.e=e;f=r?x.b:f;if(r||f){x."
+"b=r?0:o[e];x.o[e]=f}if(x.b){x.o[b]=x.b;return b}return 0};s.cet=function(f,a,t,o,b){var s=this,r,tcf;if(s.apv>=5&&(!s.isopera||s.apv>=7)){tcf=new Function('s','f','a','t','var e,r;try{r=s[f](a)}cat"
+"ch(e){r=s[t](e)}return r');r=tcf(s,f,a,t)}else{if(s.ismac&&s.u.indexOf('MSIE 4')>=0)r=s[b](a);else{s.eh(s.wd,'onerror',0,o);r=s[f](a);s.eh(s.wd,'onerror',1)}}return r};s.gtfset=function(e){var s=th"
+"is;return s.tfs};s.gtfsoe=new Function('e','var s=s_c_il['+s._in+'],c;s.eh(window,\"onerror\",1);s.etfs=1;c=s.t();if(c)s.d.write(c);s.etfs=0;return true');s.gtfsfb=function(a){return window};s.gtfs"
+"f=function(w){var s=this,p=w.parent,l=w.location;s.tfs=w;if(p&&p.location!=l&&p.location.host==l.host){s.tfs=p;return s.gtfsf(s.tfs)}return s.tfs};s.gtfs=function(){var s=this;if(!s.tfs){s.tfs=s.wd"
+";if(!s.etfs)s.tfs=s.cet('gtfsf',s.tfs,'gtfset',s.gtfsoe,'gtfsfb')}return s.tfs};s.mrq=function(u){var s=this,l=s.rl[u],n,r;s.rl[u]=0;if(l)for(n=0;n<l.length;n++){r=l[n];s.mr(0,0,r.r,0,r.t,r.u)}};s."
+"br=function(id,rs){var s=this;if(s.disableBufferedRequests||!s.c_w('s_br',rs))s.brl=rs};s.flushBufferedRequests=function(){this.fbr(0)};s.fbr=function(id){var s=this,br=s.c_r('s_br');if(!br)br=s.br"
+"l;if(br){if(!s.disableBufferedRequests)s.c_w('s_br','');s.mr(0,0,br)}s.brl=0};s.mr=function(sess,q,rs,id,ta,u){var s=this,dc=s.dc,t1=s.trackingServer,t2=s.trackingServerSecure,tb=s.trackingServerBa"
+"se,p='.sc',ns=s.visitorNamespace,un=s.cls(u?u:(ns?ns:s.fun)),r=new Object,l,imn='s_i_'+(un),im,b,e;if(!rs){if(t1){if(t2&&s.ssl)t1=t2}else{if(!tb)tb='2o7.net';if(dc)dc=(''+dc).toLowerCase();else dc="
+"'d1';if(tb=='2o7.net'){if(dc=='d1')dc='112';else if(dc=='d2')dc='122';p=''}t1=un+'.'+dc+'.'+p+tb}rs='http'+(s.ssl?'s':'')+'://'+t1+'/b/ss/'+s.un+'/'+(s.mobile?'5.1':'1')+'/H.21/'+sess+'?AQB=1&ndh=1"
+"'+(q?q:'')+'&AQE=1';if(s.isie&&!s.ismac){if(s.apv>5.5)rs=s.fl(rs,4095);else rs=s.fl(rs,2047)}if(id){s.br(id,rs);return}}if(s.d.images&&s.apv>=3&&(!s.isopera||s.apv>=7)&&(s.ns6<0||s.apv>=6.1)){if(!s"
+".rc)s.rc=new Object;if(!s.rc[un]){s.rc[un]=1;if(!s.rl)s.rl=new Object;s.rl[un]=new Array;setTimeout('if(window.s_c_il)window.s_c_il['+s._in+'].mrq(\"'+un+'\")',750)}else{l=s.rl[un];if(l){r.t=ta;r.u"
+"=un;r.r=rs;l[l.length]=r;return ''}imn+='_'+s.rc[un];s.rc[un]++}im=s.wd[imn];if(!im)im=s.wd[imn]=new Image;im.s_l=0;im.onload=new Function('e','this.s_l=1;var wd=window,s;if(wd.s_c_il){s=wd.s_c_il["
+"'+s._in+'];s.mrq(\"'+un+'\");s.nrs--;if(!s.nrs)s.m_m(\"rr\")}');if(!s.nrs){s.nrs=1;s.m_m('rs')}else s.nrs++;im.src=rs;if(rs.indexOf('&pe=')>=0&&(!ta||ta=='_self'||ta=='_top'||(s.wd.name&&ta==s.wd.n"
+"ame))){b=e=new Date;while(!im.s_l&&e.getTime()-b.getTime()<500)e=new Date}return ''}return '<im'+'g sr'+'c=\"'+rs+'\" width=1 height=1 border=0 alt=\"\">'};s.gg=function(v){var s=this;if(!s.wd['s_'"
+"+v])s.wd['s_'+v]='';return s.wd['s_'+v]};s.glf=function(t,a){if(t.substring(0,2)=='s_')t=t.substring(2);var s=this,v=s.gg(t);if(v)s[t]=v};s.gl=function(v){var s=this;if(s.pg)s.pt(v,',','glf',0)};s."
+"rf=function(x){var s=this,y,i,j,h,l,a,b='',c='',t;if(x){y=''+x;i=y.indexOf('?');if(i>0){a=y.substring(i+1);y=y.substring(0,i);h=y.toLowerCase();i=0;if(h.substring(0,7)=='http://')i+=7;else if(h.sub"
+"string(0,8)=='https://')i+=8;h=h.substring(i);i=h.indexOf(\"/\");if(i>0){h=h.substring(0,i);if(h.indexOf('google')>=0){a=s.sp(a,'&');if(a.length>1){l=',q,ie,start,search_key,word,kw,cd,';for(j=0;j<"
+"a.length;j++){t=a[j];i=t.indexOf('=');if(i>0&&l.indexOf(','+t.substring(0,i)+',')>=0)b+=(b?'&':'')+t;else c+=(c?'&':'')+t}if(b&&c){y+='?'+b+'&'+c;if(''+x!=y)x=y}}}}}}return x};s.hav=function(){var "
+"s=this,qs='',fv=s.linkTrackVars,fe=s.linkTrackEvents,mn,i;if(s.pe){mn=s.pe.substring(0,1).toUpperCase()+s.pe.substring(1);if(s[mn]){fv=s[mn].trackVars;fe=s[mn].trackEvents}}fv=fv?fv+','+s.vl_l+','+"
+"s.vl_l2:'';for(i=0;i<s.va_t.length;i++){var k=s.va_t[i],v=s[k],b=k.substring(0,4),x=k.substring(4),n=parseInt(x),q=k;if(v&&k!='linkName'&&k!='linkType'){if(s.pe||s.lnk||s.eo){if(fv&&(','+fv+',').in"
+"dexOf(','+k+',')<0)v='';if(k=='events'&&fe)v=s.fs(v,fe)}if(v){if(k=='dynamicVariablePrefix')q='D';else if(k=='visitorID')q='vid';else if(k=='pageURL'){q='g';v=s.fl(v,255)}else if(k=='referrer'){q='"
+"r';v=s.fl(s.rf(v),255)}else if(k=='vmk'||k=='visitorMigrationKey')q='vmt';else if(k=='visitorMigrationServer'){q='vmf';if(s.ssl&&s.visitorMigrationServerSecure)v=''}else if(k=='visitorMigrationServ"
+"erSecure'){q='vmf';if(!s.ssl&&s.visitorMigrationServer)v=''}else if(k=='charSet'){q='ce';if(v.toUpperCase()=='AUTO')v='ISO8859-1';else if(s.em==2)v='UTF-8'}else if(k=='visitorNamespace')q='ns';else"
+" if(k=='cookieDomainPeriods')q='cdp';else if(k=='cookieLifetime')q='cl';else if(k=='variableProvider')q='vvp';else if(k=='currencyCode')q='cc';else if(k=='channel')q='ch';else if(k=='transactionID'"
+")q='xact';else if(k=='campaign')q='v0';else if(k=='resolution')q='s';else if(k=='colorDepth')q='c';else if(k=='javascriptVersion')q='j';else if(k=='javaEnabled')q='v';else if(k=='cookiesEnabled')q="
+"'k';else if(k=='browserWidth')q='bw';else if(k=='browserHeight')q='bh';else if(k=='connectionType')q='ct';else if(k=='homepage')q='hp';else if(k=='plugins')q='p';else if(s.num(x)){if(b=='prop')q='c"
+"'+n;else if(b=='eVar')q='v'+n;else if(b=='list')q='l'+n;else if(b=='hier'){q='h'+n;v=s.fl(v,255)}}if(v)qs+='&'+q+'='+(k.substring(0,3)!='pev'?s.ape(v):v)}}}return qs};s.ltdf=function(t,h){t=t?t.toL"
+"owerCase():'';h=h?h.toLowerCase():'';var qi=h.indexOf('?');h=qi>=0?h.substring(0,qi):h;if(t&&h.substring(h.length-(t.length+1))=='.'+t)return 1;return 0};s.ltef=function(t,h){t=t?t.toLowerCase():''"
+";h=h?h.toLowerCase():'';if(t&&h.indexOf(t)>=0)return 1;return 0};s.lt=function(h){var s=this,lft=s.linkDownloadFileTypes,lef=s.linkExternalFilters,lif=s.linkInternalFilters;lif=lif?lif:s.wd.locatio"
+"n.hostname;h=h.toLowerCase();if(s.trackDownloadLinks&&lft&&s.pt(lft,',','ltdf',h))return 'd';if(s.trackExternalLinks&&h.substring(0,1)!='#'&&(lef||lif)&&(!lef||s.pt(lef,',','ltef',h))&&(!lif||!s.pt"
+"(lif,',','ltef',h)))return 'e';return ''};s.lc=new Function('e','var s=s_c_il['+s._in+'],b=s.eh(this,\"onclick\");s.lnk=s.co(this);s.t();s.lnk=0;if(b)return this[b](e);return true');s.bc=new Functi"
+"on('e','var s=s_c_il['+s._in+'],f,tcf;if(s.d&&s.d.all&&s.d.all.cppXYctnr)return;s.eo=e.srcElement?e.srcElement:e.target;tcf=new Function(\"s\",\"var e;try{if(s.eo&&(s.eo.tagName||s.eo.parentElement"
+"||s.eo.parentNode))s.t()}catch(e){}\");tcf(s);s.eo=0');s.oh=function(o){var s=this,l=s.wd.location,h=o.href?o.href:'',i,j,k,p;i=h.indexOf(':');j=h.indexOf('?');k=h.indexOf('/');if(h&&(i<0||(j>=0&&i"
+">j)||(k>=0&&i>k))){p=o.protocol&&o.protocol.length>1?o.protocol:(l.protocol?l.protocol:'');i=l.pathname.lastIndexOf('/');h=(p?p+'//':'')+(o.host?o.host:(l.host?l.host:''))+(h.substring(0,1)!='/'?l."
+"pathname.substring(0,i<0?0:i)+'/':'')+h}return h};s.ot=function(o){var t=o.tagName;t=t&&t.toUpperCase?t.toUpperCase():'';if(t=='SHAPE')t='';if(t){if((t=='INPUT'||t=='BUTTON')&&o.type&&o.type.toUppe"
+"rCase)t=o.type.toUpperCase();else if(!t&&o.href)t='A';}return t};s.oid=function(o){var s=this,t=s.ot(o),p,c,n='',x=0;if(t&&!o.s_oid){p=o.protocol;c=o.onclick;if(o.href&&(t=='A'||t=='AREA')&&(!c||!p"
+"||p.toLowerCase().indexOf('javascript')<0))n=s.oh(o);else if(c){n=s.rep(s.rep(s.rep(s.rep(''+c,\"\\r\",''),\"\\n\",''),\"\\t\",''),' ','');x=2}else if(t=='INPUT'||t=='SUBMIT'){if(o.value)n=o.value;"
+"else if(o.innerText)n=o.innerText;else if(o.textContent)n=o.textContent;x=3}else if(o.src&&t=='IMAGE')n=o.src;if(n){o.s_oid=s.fl(n,100);o.s_oidt=x}}return o.s_oid};s.rqf=function(t,un){var s=this,e"
+"=t.indexOf('='),u=e>=0?','+t.substring(0,e)+',':'';return u&&u.indexOf(','+un+',')>=0?s.epa(t.substring(e+1)):''};s.rq=function(un){var s=this,c=un.indexOf(','),v=s.c_r('s_sq'),q='';if(c<0)return s"
+".pt(v,'&','rqf',un);return s.pt(un,',','rq',0)};s.sqp=function(t,a){var s=this,e=t.indexOf('='),q=e<0?'':s.epa(t.substring(e+1));s.sqq[q]='';if(e>=0)s.pt(t.substring(0,e),',','sqs',q);return 0};s.s"
+"qs=function(un,q){var s=this;s.squ[un]=q;return 0};s.sq=function(q){var s=this,k='s_sq',v=s.c_r(k),x,c=0;s.sqq=new Object;s.squ=new Object;s.sqq[q]='';s.pt(v,'&','sqp',0);s.pt(s.un,',','sqs',q);v='"
+"';for(x in s.squ)if(x&&(!Object||!Object.prototype||!Object.prototype[x]))s.sqq[s.squ[x]]+=(s.sqq[s.squ[x]]?',':'')+x;for(x in s.sqq)if(x&&(!Object||!Object.prototype||!Object.prototype[x])&&s.sqq["
+"x]&&(x==q||c<2)){v+=(v?'&':'')+s.sqq[x]+'='+s.ape(x);c++}return s.c_w(k,v,0)};s.wdl=new Function('e','var s=s_c_il['+s._in+'],r=true,b=s.eh(s.wd,\"onload\"),i,o,oc;if(b)r=this[b](e);for(i=0;i<s.d.l"
+"inks.length;i++){o=s.d.links[i];oc=o.onclick?\"\"+o.onclick:\"\";if((oc.indexOf(\"s_gs(\")<0||oc.indexOf(\".s_oc(\")>=0)&&oc.indexOf(\".tl(\")<0)s.eh(o,\"onclick\",0,s.lc);}return r');s.wds=functio"
+"n(){var s=this;if(s.apv>3&&(!s.isie||!s.ismac||s.apv>=5)){if(s.b&&s.b.attachEvent)s.b.attachEvent('onclick',s.bc);else if(s.b&&s.b.addEventListener)s.b.addEventListener('click',s.bc,false);else s.e"
+"h(s.wd,'onload',0,s.wdl)}};s.vs=function(x){var s=this,v=s.visitorSampling,g=s.visitorSamplingGroup,k='s_vsn_'+s.un+(g?'_'+g:''),n=s.c_r(k),e=new Date,y=e.getYear();e.setYear(y+10+(y<1900?1900:0));"
+"if(v){v*=100;if(!n){if(!s.c_w(k,x,e))return 0;n=x}if(n%10000>v)return 0}return 1};s.dyasmf=function(t,m){if(t&&m&&m.indexOf(t)>=0)return 1;return 0};s.dyasf=function(t,m){var s=this,i=t?t.indexOf('"
+"='):-1,n,x;if(i>=0&&m){var n=t.substring(0,i),x=t.substring(i+1);if(s.pt(x,',','dyasmf',m))return n}return 0};s.uns=function(){var s=this,x=s.dynamicAccountSelection,l=s.dynamicAccountList,m=s.dyna"
+"micAccountMatch,n,i;s.un=s.un.toLowerCase();if(x&&l){if(!m)m=s.wd.location.host;if(!m.toLowerCase)m=''+m;l=l.toLowerCase();m=m.toLowerCase();n=s.pt(l,';','dyasf',m);if(n)s.un=n}i=s.un.indexOf(',');"
+"s.fun=i<0?s.un:s.un.substring(0,i)};s.sa=function(un){var s=this;s.un=un;if(!s.oun)s.oun=un;else if((','+s.oun+',').indexOf(','+un+',')<0)s.oun+=','+un;s.uns()};s.m_i=function(n,a){var s=this,m,f=n"
+".substring(0,1),r,l,i;if(!s.m_l)s.m_l=new Object;if(!s.m_nl)s.m_nl=new Array;m=s.m_l[n];if(!a&&m&&m._e&&!m._i)s.m_a(n);if(!m){m=new Object,m._c='s_m';m._in=s.wd.s_c_in;m._il=s._il;m._il[m._in]=m;s."
+"wd.s_c_in++;m.s=s;m._n=n;m._l=new Array('_c','_in','_il','_i','_e','_d','_dl','s','n','_r','_g','_g1','_t','_t1','_x','_x1','_rs','_rr','_l');s.m_l[n]=m;s.m_nl[s.m_nl.length]=n}else if(m._r&&!m._m)"
+"{r=m._r;r._m=m;l=m._l;for(i=0;i<l.length;i++)if(m[l[i]])r[l[i]]=m[l[i]];r._il[r._in]=r;m=s.m_l[n]=r}if(f==f.toUpperCase())s[n]=m;return m};s.m_a=new Function('n','g','e','if(!g)g=\"m_\"+n;var s=s_c"
+"_il['+s._in+'],c=s[g+\"_c\"],m,x,f=0;if(!c)c=s.wd[\"s_\"+g+\"_c\"];if(c&&s_d)s[g]=new Function(\"s\",s_ft(s_d(c)));x=s[g];if(!x)x=s.wd[\\'s_\\'+g];if(!x)x=s.wd[g];m=s.m_i(n,1);if(x&&(!m._i||g!=\"m_"
+"\"+n)){m._i=f=1;if((\"\"+x).indexOf(\"function\")>=0)x(s);else s.m_m(\"x\",n,x,e)}m=s.m_i(n,1);if(m._dl)m._dl=m._d=0;s.dlt();return f');s.m_m=function(t,n,d,e){t='_'+t;var s=this,i,x,m,f='_'+t,r=0,"
+"u;if(s.m_l&&s.m_nl)for(i=0;i<s.m_nl.length;i++){x=s.m_nl[i];if(!n||x==n){m=s.m_i(x);u=m[t];if(u){if((''+u).indexOf('function')>=0){if(d&&e)u=m[t](d,e);else if(d)u=m[t](d);else u=m[t]()}}if(u)r=1;u="
+"m[t+1];if(u&&!m[f]){if((''+u).indexOf('function')>=0){if(d&&e)u=m[t+1](d,e);else if(d)u=m[t+1](d);else u=m[t+1]()}}m[f]=1;if(u)r=1}}return r};s.m_ll=function(){var s=this,g=s.m_dl,i,o;if(g)for(i=0;"
+"i<g.length;i++){o=g[i];if(o)s.loadModule(o.n,o.u,o.d,o.l,o.e,1);g[i]=0}};s.loadModule=function(n,u,d,l,e,ln){var s=this,m=0,i,g,o=0,f1,f2,c=s.h?s.h:s.b,b,tcf;if(n){i=n.indexOf(':');if(i>=0){g=n.sub"
+"string(i+1);n=n.substring(0,i)}else g=\"m_\"+n;m=s.m_i(n)}if((l||(n&&!s.m_a(n,g)))&&u&&s.d&&c&&s.d.createElement){if(d){m._d=1;m._dl=1}if(ln){if(s.ssl)u=s.rep(u,'http:','https:');i='s_s:'+s._in+':'"
+"+n+':'+g;b='var s=s_c_il['+s._in+'],o=s.d.getElementById(\"'+i+'\");if(s&&o){if(!o.l&&s.wd.'+g+'){o.l=1;if(o.i)clearTimeout(o.i);o.i=0;s.m_a(\"'+n+'\",\"'+g+'\"'+(e?',\"'+e+'\"':'')+')}';f2=b+'o.c+"
+"+;if(!s.maxDelay)s.maxDelay=250;if(!o.l&&o.c<(s.maxDelay*2)/100)o.i=setTimeout(o.f2,100)}';f1=new Function('e',b+'}');tcf=new Function('s','c','i','u','f1','f2','var e,o=0;try{o=s.d.createElement("
+"\"script\");if(o){o.type=\"text/javascript\";'+(n?'o.id=i;o.defer=true;o.onload=o.onreadystatechange=f1;o.f2=f2;o.l=0;':'')+'o.src=u;c.appendChild(o);'+(n?'o.c=0;o.i=setTimeout(f2,100)':'')+'}}catc"
+"h(e){o=0}return o');o=tcf(s,c,i,u,f1,f2)}else{o=new Object;o.n=n+':'+g;o.u=u;o.d=d;o.l=l;o.e=e;g=s.m_dl;if(!g)g=s.m_dl=new Array;i=0;while(i<g.length&&g[i])i++;g[i]=o}}else if(n){m=s.m_i(n);m._e=1}"
+"return m};s.vo1=function(t,a){if(a[t]||a['!'+t])this[t]=a[t]};s.vo2=function(t,a){if(!a[t]){a[t]=this[t];if(!a[t])a['!'+t]=1}};s.dlt=new Function('var s=s_c_il['+s._in+'],d=new Date,i,vo,f=0;if(s.d"
+"ll)for(i=0;i<s.dll.length;i++){vo=s.dll[i];if(vo){if(!s.m_m(\"d\")||d.getTime()-vo._t>=s.maxDelay){s.dll[i]=0;s.t(vo)}else f=1}}if(s.dli)clearTimeout(s.dli);s.dli=0;if(f){if(!s.dli)s.dli=setTimeout"
+"(s.dlt,s.maxDelay)}else s.dll=0');s.dl=function(vo){var s=this,d=new Date;if(!vo)vo=new Object;s.pt(s.vl_g,',','vo2',vo);vo._t=d.getTime();if(!s.dll)s.dll=new Array;s.dll[s.dll.length]=vo;if(!s.max"
+"Delay)s.maxDelay=250;s.dlt()};s.t=function(vo,id){var s=this,trk=1,tm=new Date,sed=Math&&Math.random?Math.floor(Math.random()*10000000000000):tm.getTime(),sess='s'+Math.floor(tm.getTime()/10800000)"
+"%10+sed,y=tm.getYear(),vt=tm.getDate()+'/'+tm.getMonth()+'/'+(y<1900?y+1900:y)+' '+tm.getHours()+':'+tm.getMinutes()+':'+tm.getSeconds()+' '+tm.getDay()+' '+tm.getTimezoneOffset(),tcf,tfs=s.gtfs(),"
+"ta='',q='',qs='',code='',vb=new Object;s.gl(s.vl_g);s.uns();s.m_ll();if(!s.td){var tl=tfs.location,a,o,i,x='',c='',v='',p='',bw='',bh='',j='1.0',k=s.c_w('s_cc','true',0)?'Y':'N',hp='',ct='',pn=0,ps"
+";if(String&&String.prototype){j='1.1';if(j.match){j='1.2';if(tm.setUTCDate){j='1.3';if(s.isie&&s.ismac&&s.apv>=5)j='1.4';if(pn.toPrecision){j='1.5';a=new Array;if(a.forEach){j='1.6';i=0;o=new Objec"
+"t;tcf=new Function('o','var e,i=0;try{i=new Iterator(o)}catch(e){}return i');i=tcf(o);if(i&&i.next)j='1.7'}}}}}if(s.apv>=4)x=screen.width+'x'+screen.height;if(s.isns||s.isopera){if(s.apv>=3){v=s.n."
+"javaEnabled()?'Y':'N';if(s.apv>=4){c=screen.pixelDepth;bw=s.wd.innerWidth;bh=s.wd.innerHeight}}s.pl=s.n.plugins}else if(s.isie){if(s.apv>=4){v=s.n.javaEnabled()?'Y':'N';c=screen.colorDepth;if(s.apv"
+">=5){bw=s.d.documentElement.offsetWidth;bh=s.d.documentElement.offsetHeight;if(!s.ismac&&s.b){tcf=new Function('s','tl','var e,hp=0;try{s.b.addBehavior(\"#default#homePage\");hp=s.b.isHomePage(tl)?"
+"\"Y\":\"N\"}catch(e){}return hp');hp=tcf(s,tl);tcf=new Function('s','var e,ct=0;try{s.b.addBehavior(\"#default#clientCaps\");ct=s.b.connectionType}catch(e){}return ct');ct=tcf(s)}}}else r=''}if(s.p"
+"l)while(pn<s.pl.length&&pn<30){ps=s.fl(s.pl[pn].name,100)+';';if(p.indexOf(ps)<0)p+=ps;pn++}s.resolution=x;s.colorDepth=c;s.javascriptVersion=j;s.javaEnabled=v;s.cookiesEnabled=k;s.browserWidth=bw;"
+"s.browserHeight=bh;s.connectionType=ct;s.homepage=hp;s.plugins=p;s.td=1}if(vo){s.pt(s.vl_g,',','vo2',vb);s.pt(s.vl_g,',','vo1',vo)}if(s.usePlugins)s.doPlugins(s);var l=s.wd.location,r=tfs.document."
+"referrer;if(!s.pageURL)s.pageURL=l.href?l.href:l;if(!s.referrer&&!s._1_referrer){s.referrer=r;s._1_referrer=1}if((vo&&vo._t)||!s.m_m('d')){s.m_m('g');if(s.lnk||s.eo){var o=s.eo?s.eo:s.lnk;if(!o)ret"
+"urn '';var p=s.pageName,w=1,t=s.ot(o),n=s.oid(o),x=o.s_oidt,h,l,i,oc;if(s.eo&&o==s.eo){while(o&&!n&&t!='BODY'){o=o.parentElement?o.parentElement:o.parentNode;if(!o)return '';t=s.ot(o);n=s.oid(o);x="
+"o.s_oidt}oc=o.onclick?''+o.onclick:'';if((oc.indexOf(\"s_gs(\")>=0&&oc.indexOf(\".s_oc(\")<0)||oc.indexOf(\".tl(\")>=0)return ''}ta=n?o.target:1;h=s.oh(o);i=h.indexOf('?');h=s.linkLeaveQueryString|"
+"|i<0?h:h.substring(0,i);l=s.linkName;t=s.linkType?s.linkType.toLowerCase():s.lt(h);if(t&&(h||l))q+='&pe=lnk_'+(t=='d'||t=='e'?s.ape(t):'o')+(h?'&pev1='+s.ape(h):'')+(l?'&pev2='+s.ape(l):'');else tr"
+"k=0;if(s.trackInlineStats){if(!p){p=s.pageURL;w=0}t=s.ot(o);i=o.sourceIndex;if(s.gg('objectID')){n=s.gg('objectID');x=1;i=1}if(p&&n&&t)qs='&pid='+s.ape(s.fl(p,255))+(w?'&pidt='+w:'')+'&oid='+s.ape("
+"s.fl(n,100))+(x?'&oidt='+x:'')+'&ot='+s.ape(t)+(i?'&oi='+i:'')}}if(!trk&&!qs)return '';s.sampled=s.vs(sed);if(trk){if(s.sampled)code=s.mr(sess,(vt?'&t='+s.ape(vt):'')+s.hav()+q+(qs?qs:s.rq(s.un)),0"
+",id,ta);qs='';s.m_m('t');if(s.p_r)s.p_r();s.referrer=''}s.sq(qs);}else{s.dl(vo);}if(vo)s.pt(s.vl_g,',','vo1',vb);s.lnk=s.eo=s.linkName=s.linkType=s.wd.s_objectID=s.ppu=s.pe=s.pev1=s.pev2=s.pev3='';"
+"if(s.pg)s.wd.s_lnk=s.wd.s_eo=s.wd.s_linkName=s.wd.s_linkType='';if(!id&&!s.tc){s.tc=1;s.flushBufferedRequests()}return code};s.tl=function(o,t,n,vo){var s=this;s.lnk=s.co(o);s.linkType=t;s.linkName"
+"=n;s.t(vo)};if(pg){s.wd.s_co=function(o){var s=s_gi(\"_\",1,1);return s.co(o)};s.wd.s_gs=function(un){var s=s_gi(un,1,1);return s.t()};s.wd.s_dc=function(un){var s=s_gi(un,1);return s.t()}}s.ssl=(s"
+".wd.location.protocol.toLowerCase().indexOf('https')>=0);s.d=document;s.b=s.d.body;if(s.d.getElementsByTagName){s.h=s.d.getElementsByTagName('HEAD');if(s.h)s.h=s.h[0]}s.n=navigator;s.u=s.n.userAgen"
+"t;s.ns6=s.u.indexOf('Netscape6/');var apn=s.n.appName,v=s.n.appVersion,ie=v.indexOf('MSIE '),o=s.u.indexOf('Opera '),i;if(v.indexOf('Opera')>=0||o>0)apn='Opera';s.isie=(apn=='Microsoft Internet Exp"
+"lorer');s.isns=(apn=='Netscape');s.isopera=(apn=='Opera');s.ismac=(s.u.indexOf('Mac')>=0);if(o>0)s.apv=parseFloat(s.u.substring(o+6));else if(ie>0){s.apv=parseInt(i=v.substring(ie+5));if(s.apv>3)s."
+"apv=parseFloat(i)}else if(s.ns6>0)s.apv=parseFloat(s.u.substring(s.ns6+10));else s.apv=parseFloat(v);s.em=0;if(String.fromCharCode){i=escape(String.fromCharCode(256)).toUpperCase();s.em=(i=='%C4%80"
+"'?2:(i=='%U0100'?1:0))}s.sa(un);s.vl_l='dynamicVariablePrefix,visitorID,vmk,visitorMigrationKey,visitorMigrationServer,visitorMigrationServerSecure,ppu,charSet,visitorNamespace,cookieDomainPeriods,"
+"cookieLifetime,pageName,pageURL,referrer,currencyCode';s.va_l=s.sp(s.vl_l,',');s.vl_t=s.vl_l+',variableProvider,channel,server,pageType,transactionID,purchaseID,campaign,state,zip,events,products,l"
+"inkName,linkType';for(var n=1;n<51;n++)s.vl_t+=',prop'+n+',eVar'+n+',hier'+n+',list'+n;s.vl_l2=',tnt,pe,pev1,pev2,pev3,resolution,colorDepth,javascriptVersion,javaEnabled,cookiesEnabled,browserWidt"
+"h,browserHeight,connectionType,homepage,plugins';s.vl_t+=s.vl_l2;s.va_t=s.sp(s.vl_t,',');s.vl_g=s.vl_t+',trackingServer,trackingServerSecure,trackingServerBase,fpCookieDomainPeriods,disableBuffered"
+"Requests,mobile,visitorSampling,visitorSamplingGroup,dynamicAccountSelection,dynamicAccountList,dynamicAccountMatch,trackDownloadLinks,trackExternalLinks,trackInlineStats,linkLeaveQueryString,linkD"
+"ownloadFileTypes,linkExternalFilters,linkInternalFilters,linkTrackVars,linkTrackEvents,linkNames,lnk,eo,_1_referrer';s.va_g=s.sp(s.vl_g,',');s.pg=pg;s.gl(s.vl_g);if(!ss)s.wds()",
w=window,l=w.s_c_il,n=navigator,u=n.userAgent,v=n.appVersion,e=v.indexOf('MSIE '),m=u.indexOf('Netscape6/'),a,i,s;if(un){un=un.toLowerCase();if(l)for(i=0;i<l.length;i++){s=l[i];if(!s._c||s._c=='s_c'){if(s.oun==un)return s;else if(s.fs&&s.sa&&s.fs(s.oun,un)){s.sa(un);return s}}}}w.s_an='0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz';
w.s_sp=new Function("x","d","var a=new Array,i=0,j;if(x){if(x.split)a=x.split(d);else if(!d)for(i=0;i<x.length;i++)a[a.length]=x.substring(i,i+1);else while(i>=0){j=x.indexOf(d,i);a[a.length]=x.subst"
+"ring(i,j<0?x.length:j);i=j;if(i>=0)i+=d.length}}return a");
w.s_jn=new Function("a","d","var x='',i,j=a.length;if(a&&j>0){x=a[0];if(j>1){if(a.join)x=a.join(d);else for(i=1;i<j;i++)x+=d+a[i]}}return x");
w.s_rep=new Function("x","o","n","return s_jn(s_sp(x,o),n)");
w.s_d=new Function("x","var t='`^@$#',l=s_an,l2=new Object,x2,d,b=0,k,i=x.lastIndexOf('~~'),j,v,w;if(i>0){d=x.substring(0,i);x=x.substring(i+2);l=s_sp(l,'');for(i=0;i<62;i++)l2[l[i]]=i;t=s_sp(t,'');d"
+"=s_sp(d,'~');i=0;while(i<5){v=0;if(x.indexOf(t[i])>=0) {x2=s_sp(x,t[i]);for(j=1;j<x2.length;j++){k=x2[j].substring(0,1);w=t[i]+k;if(k!=' '){v=1;w=d[b+l2[k]]}x2[j]=w+x2[j].substring(1)}}if(v)x=s_jn("
+"x2,'');else{w=t[i]+' ';if(x.indexOf(w)>=0)x=s_rep(x,w,t[i]);i++;b+=62}}}return x");
w.s_fe=new Function("c","return s_rep(s_rep(s_rep(c,'\\\\','\\\\\\\\'),'\"','\\\\\"'),\"\\n\",\"\\\\n\")");
w.s_fa=new Function("f","var s=f.indexOf('(')+1,e=f.indexOf(')'),a='',c;while(s>=0&&s<e){c=f.substring(s,s+1);if(c==',')a+='\",\"';else if((\"\\n\\r\\t \").indexOf(c)<0)a+=c;s++}return a?'\"'+a+'\"':"
+"a");
w.s_ft=new Function("c","c+='';var s,e,o,a,d,q,f,h,x;s=c.indexOf('=function(');while(s>=0){s++;d=1;q='';x=0;f=c.substring(s);a=s_fa(f);e=o=c.indexOf('{',s);e++;while(d>0){h=c.substring(e,e+1);if(q){i"
+"f(h==q&&!x)q='';if(h=='\\\\')x=x?0:1;else x=0}else{if(h=='\"'||h==\"'\")q=h;if(h=='{')d++;if(h=='}')d--}if(d>0)e++}c=c.substring(0,s)+'new Function('+(a?a+',':'')+'\"'+s_fe(c.substring(o+1,e))+'\")"
+"'+c.substring(e+1);s=c.indexOf('=function(')}return c;");
c=s_d(c);if(e>0){a=parseInt(i=v.substring(e+5));if(a>3)a=parseFloat(i)}else if(m>0)a=parseFloat(u.substring(m+10));else a=parseFloat(v);if(a>=5&&v.indexOf('Opera')<0&&u.indexOf('Opera')<0){w.s_c=new Function("un","pg","ss","var s=this;"+c);return new s_c(un,pg,ss)}else s=new Function("un","pg","ss","var s=new Object;"+s_ft(c)+";return s");return s(un,pg,ss)}


