Specifications - 1260 Infinity Fraction Collectors 

white
clear clear clear clear clear

grey1
Literature Library
Technical Support
Education & Events

grey1


 

Agilent 1260 Infinity Analytical-scale Fraction Collector

Agilent 1260 Infinity Preparative-scale Fraction Collector

Delay volume

Approximately 50 μL

Approximately 500 μL

Maximum system flow

10 mL/min, or up to 100 mL/min with semiprep needle and 0.8 mm tubing

100 mL/min

Fraction containers

  • Shallow or deep well plates up to 48 mm height (96 or 384 format)
  • Test tubes up to 48 mm height, or up to 75 mm height with semiprep needle
  • Autosampler vials (2 mL and 6 mL)
  • Eppendorf safe-lock tubes (0.5 mL, 1.5 mL , 2.5 mL)
  • 96 deep well plates up to 48 mm height
  • Test tubes, minimum 48 mm up to maximum 100 mm height (up to
    45 mL)
  • Autosampler vials (2 mL and 6 mL)

Fraction trays

Full trays

  • 4 well plates
  • 40 x 20 mL test tubes (30 mm od, 48 mm height)
  • 60 x 15mL test tubes (25 mm od, 48 mm height)
  • 126 x 8mL test tubes (16 mm od, 48 mm height)
  • 215 x 5 mL test tubes (12 mm od, 48 mm height)
  • 2 well plates + 10 x 2 mL vials
    (+ one possible additional half tray)
     
     
     
  • 2 well plates + 10 funnels for collection in external containers
    (+ one additional half tray)
  • 100 x 2 mL vials (+ one possible additional half tray)

Half trays (up to 3 per fraction collector)

  • 40 funnel tray
  • 15 x 6 mL vial
  • 40 x 2 ml vial

Tube plates for well plate trays

(2 or 4 per fraction collector depending on well plate tray):
Eppendorf safe-lock tubes (27 x 0.5 ml, 1.5 ml or 2.5 ml)
24 test tubes (18 mm OD)
54 x 2 ml vial
15 x 6 ml vial

Full trays

  • 4 well plates
  • 40 x 45 mL test tubes (30 mm OD, 100 mm height)
  • 60 x 32 mL test tubes (25 mm OD, 100 mm height)
  • 126 x 13 mL test tubes (16 mm OD, 100 mm height)
  • 215 x 7.5 mL test tubes (12 mm OD, 100 mm height)
  • 2 well plates + 10 x 2 mL vials
    (+ one possible additional half tray)
  • 100 x 2 mL
    (+ one possible additional half tray)
     
     
     
     
     

 
Half trays (up to 3 per fraction collector)

  • 15 x 6 mL vial
  • 40 x 2 ml vial
     

Tube plates for well plate trays

(2 or 4 per fraction collector depending on well plate tray):
Eppendorf safe-lock tubes (27 x 0.5 ml, 1.5 ml or 2.5 ml)
24 test tubes (18 mm OD)
54 x 2 ml vial
15 x 6 ml vial

Cooling

Optional

Optional

Note: 2 mL vials are possible with preparative fraction collector but not recommended

Specifications common to both 1260 Infinity Fraction Collectors

Trigger modes

Time slices and peak (threshold, up-/downslope, upper threshold and timetable), Boolean logic for different detector signals, combination of different modes, manual trigger (supported with 1200 Series Instant Pilot)

Trigger source

Agilent 1200 Series VWD (only for analytical scale), MWD and DAD detectors, Agilent 6100 Series Quadrupole LC/MS, third party detectors (require UIB)

Diverter valve

3/2 valve, switching time < 100 ms

Maximum pressure

6 bar

Maximum capacity

3 fraction collectors connected in parallel through a 12-position/13-port selection valve

Environment

4 – 55 °C constant temperature, < 95% humidity (non-condensing)

 
 