CE Capillary Solution Kits The CE Capillary Solution Kits include all you need to begin your CE analyses: buffers, capillaries, conditioning solutions, test samples, and methods. Each kit is designed to take advantage of the automation of the Agilent CE system to make your time in the laboratory more efficient. All kits are prepared using the same quality procedures as for our buffers and are thoroughly tested and supported.
| Description |
Product number |
Plating Bath Analysis Kit This kit is intended for the analysis of inorganic and organic anions together with some metal cations (e.g. Ni 2+, Cu2+, Co2+) in electroless plating bath solutions. The anionic background electrolyte forms negatively charged complexes with metal cations. These complexes migrate towards the positive electrode and can therefore be analyzed together with other anions in a single run. Indirect UV detection is employed with this kit to visualize anions which have little or no chromophore. Metal cations, which have UV-absorbance, are therefore recorded as negative peaks.The kit is also suitable for the analysis of electro-iron plating solutions, where different levels of Fe2+ and Fe3+ need to be monitored. |
5064-8228 |
Forensic Anion Solutions Kit This kit contains everything needed for the analysis of toxic anions such as arsenate, arsenite, azide or cyanide. Other inorganic and organic anions can also be analyzed. Since most analytes of these types do not have significant UV absorption, the method uses indirect UV detection. |
5064-8208 |
Cation Solutions Kit This kit provides everything needed for the analysis of inorganic and low molecular-mass organic cations. It has been specially designed for the analysis of alkali metal ions, alkaline-earth metal ions and alkyl amines in a wide range of matrices. The kit can be used in various application areas, such as water analysis, for determining cations in food and beverages (beer, wine, juice, milk) and OTC (over-the counter) drugs. In addition, alkylamines in industrial chemicals, such as cooling liquids, can be determined. |
5064-8206 |
Chiral Methods Development This Application Note helps to simplify the methods development process for chiral analytes. The note describes a variety of cyclodextrins and buffers together with a rational methods development process and is suitable for a broad range of chiral analytes. |
5988-4305EN |
Inorganic Anions Solutions Kit This kit contains all components needed for the analysis of common inorganic anions such as chloride, bromide, iodide, fluoride, sulfate, and phosphate. Indirect UV-detection is used to visualize anions with little or no chromphore. The kit can be used in various application areas, e.g. chemical, food and environmental analysis. |
5063-6511 |
Organic Acids Solutions Kit This kit is ideal for the analysis of short alkyl-chain carboxylic acids. Employing an indirect UV detection agent optimized for organic acids, the methodology is simple, sensitive, and provides accurate quantitative analysis. Suited for analysis of organic acids in a wide range of matrices, it is especially useful for determination of organic acids in beer, wine, juice and food. |
5063-6510 |
Double Stranded DNA and PCR Analysis This Application Note describes a convenient method for analyzing double stranded DNA by capillary electrophoresis. Using a dissolved polymer sieving system, size-dependent DNA separations are simple, efficient, and highly automated. The separation buffer can be rapidly flushed from the capillary to maintain reproducible separations and prevent fouling from run to run. |
5988-4304EN |
Oligonucleotide Analysis This Application Note contains everything needed to analyze short oligonucleotides of DNA and RNA, and antisense oligonucleotides. In addition, single-stranded and double-stranded oligonucleotides can be analyzed in a single run. The analysis is fast, reproducible and highly automated, making it ideally suited for quality control applications in oligonucleotides core facilities as well as in many phases of bio-pharmaceutical drug development. The Agilent CE system allows automated fraction collection for subsequent MALDI-TOF MS or other offline analysis. |
5988-4303EN |
µPage Gel-filled Capillaries for High Resolution DNA Fragments Analysis
| µPAGE poly-acrylamide gel-filled capillaries are the most direct vehicles to transfer all of your applications from slab gel to CE, enjoying the automation, high speed, high resolution, and quantitative advantages of CE. The capillaries are ideal for high resolution separations of oligonucleotides, single-stranded and double-stranded DNA fragments, polymerase chain reaction (PCR) products, sequencing reaction products and oligosaccharides. |
µPAGE Starter Kit Includes 3 µPAGE capillaries, 75 cm total length, 50 cm effective length, µPAGE pd(A)25-30, 40-60 oligonucleotide standard for µPAGE-3 and µPage-5 kits, µPAGE pd(A)25-30 oligonucleotide standard for µPAGE-10 kit, µPAGE buffer, 2 x 237 mL |
| µPAGE-10 (10 % T, 0 %C), 100 µm id |
192-1311 |
| µPAGE-5 (5 % T, 5 %C), 75 µm id |
192-5211 |
| µPAGE-3 (3 % T, 3 %C), 75 µm id |
192-3211 |
µPAGE Basic Kit Includes 3 µPAGE capillaries, 75 cm total length, 50 cm effective length, µPAGE pd(A)25-30, 40-60 oligonucleotide standard for µPAGE-3 and µPage-5 kits, µPAGE pd(A)25-30 oligonucleotide standard for µPAGE-10 kit |
| µPAGE-10 (10 % T, 0 %C), 100 µm id |
191-1311 |
| µPAGE-5 (5 % T, 5 %C), 75 µm id |
191-5211 |
| µPAGE-3 (3 % T, 3 %C), 75 µm id |
191-3211 |
CE Solution Kits Overview
|
|