HP Expands HPLC Column Selection with ZORBAX®
Hewlett-Packard recently announced the acquisition of Rockland Technologies,
Inc. (RTI), a leading research and manufacturing company dedicated to providing
analytical chemists and biochemists with high-quality ZORBAX HPLC columns. RTI's
facility and all employees, now HP's Little Falls Analytical Division Newport Site,
will continue to produce high-purity silica particles, perform proprietary bonding
chemistries, and pack superior-quality ZORBAX HPLC columns.

Figure 1. Sterically protected, monolayer bonding. |
The ZORBAX product line is built on high-purity, robust silica-based stationary phases. Column
reproducibility is ensured by the mechanical strength and stability from patented
porous silica microspheres. By using only high-purity materials with low metal contamination,
ZORBAX packings are ultrapure (>99.995 %) silica, eliminating peak tailing due to solute
interaction with trace impurities and more acidic silanols. The silica is also enriched for
less acidic associated silanols, also minimizing tailing of basic compounds.
Designed for use at low pH, ZORBAX StableBond columns use a patented bonding chemistry that insures long
column life. This chemistry uses unique silanes to sterically protect the siloxane bond at
low pH. StableBond phases are extremely acid-stable, even for short-chain CN and C3, allowing
a wide range of reliable selectivity. These stable, shorter chain phases are often effectively
used for separations not possible using either C8 or C18 phases. StableBond's unique chemistry
is stable at low pH even at high temperatures, which can be used to enhance selectivity for
particularly difficult separations.
| Mobile Phase: |
60% ACN 40% 10 mM
phosphate buffer pH 7.0 |
| Flow Rate: |
1.5 mL/min |
| Temperature: |
40°C |
| Sample: |
- Notriptyline
- Doxepin
- Amitriptyline
- Trimipramine
|
|

Figure 2. Double-endcapped Eclipse XDB-C8 column. |
ZORBAX Eclipse XDB reverse-phase columns offer
excellent, symmetrical peak shapes and extended column life in the mid-pH range.
These columns are recommended for compounds that are labile at low pH, or with methods
specifying mid-pH
conditions. Eclipse XDB columns combine extra dense bonding to the
ultrapure silica surface, followed by endcapping with two different reagents to increase
stability while improving peak shape for acidic, neutral, and basic compounds.
For the biotechnology lab, the high efficiency and physical stability of ZORBAX GF-250 and GF-450
size-exclusion columns accommodate high flow rates, greatly reducing analysis time.
A patented zirconium-modified silica surface extends the pH range of these columns providing
more flexibility. ZORBAX Bio Series columns also include ion exchange and oligo mixed-mode
columns.
ZORBAX products address a
wide range of HPLC applications, including
pharmaceuticals, proteins, peptides, and nucleic acids. In addition to popular StableBond
and Eclipse reverse-phase columns, ZORBAX technology is available in normal-phase,
size-exclusion, gel-filtration, ion-exchange, and oligo columns.