Agilent Technologies

List of measurement possibilities for Ethylene

Ethylene
Method Provider Description
ASTM
D2504-88
(1993)e1
Agilent
AC
SSI
Wasson
Noncondensable Gases in C2 and Lighter Hydrocarbons
ASTM
D2505-88
(1993)e1
Agilent
AC
Wasson
Ethylene, Other Hydrocarbons, and Carbon Dioxide in High-Purity Ethylene
ASTM
D2650-93
MMS Chemical Composition of Gases by Mass Spectrometry
ASTM
D5504-94
AC
OI
Sievers
Wasson
Sulfur Compounds in Natural Gas and Gaseous Fuels
ASTM
D5623-94
Agilent
AC
Sievers
Sulfur Compounds in Light Petroleum Liquids by GC and Sulfur Selective Detection
ASTM
D6159-97
Agilent
AC
SSI
Wasson
Hydrocarbon Impurities in Ethylene
IP CD/97 Wasson Hydrocarbon Impurities in Ethylene
IP CD/97
(proposed)
Agilent
AC
Wasson
Composition of Liquefied Petroleum Gases
462-00 Wasson Contaminates in High Purity Ethylene and Propylene by GC/MS
260-00 Wasson Impurities in Polymer Grade Ethylene
262-00 Wasson Impurities in Polymer Grade Ethylene and Propylene
  Agilent Analysis of Fixed Gases, Alkanes, Alkenes, Alkynes and Dienes in Refinery Gases Within 160 seconds
  Agilent Oxygen, Nitrogen, Methane, Carbon Dioxide, Acetylene, Ethylene and Ethane Within 90 seconds
  Agilent High Speed Analysis of Impurities in Ethane, Ethylene, Propane, Propylene and Butane
  Sievers Determination of Sulfur Compounds in Propylene and Ethylene by Gas Chromatography and Chemiluminescence detection
  Agilent Sulfur and Nitrogen Compounds in Gasoline through Diesel Range Liquids by GC-AED
  Agilent Impurities in Polymer Grade Ethylene and Propylene By GC-AED
  Agilent Multi-Element Analysis of Heteroatomic Compounds in Gasoline through Diesel Range Liquids by GC-AED
  AC Determination of Sulfur Traces in Ethylene and Propylene
  Wasson Standard Refinery Gases
  Wasson Extended Refinery Gases
  AC Traces of ethers and alcohols in gasoline
  AC Determination of Sulfur Traces in Ethylenen and Propylene
  SSI Analysis of Trace Methanol in Ethylene, Propylene and Butadiene by Gas Chromatograph
  SSI Trace Analysis of CO and CO2 in Ethylene and Propylene
  SSI Determination of Trace Hydrogen Impurities in Polymer Grade Ethylene and Propylene by Gas Chromatography
  OI Low level S analysis -ppm to sub-ppb
  OI Low Level Arsenic in LPG Streams
  Agilent C1-C10 Hydrocarbon Analysis Within 8 Minutes
  Agilent Ethylene Purity Analysis by GC
  Sievers Separation and Detection of Carbonyl Sulfide and Hydrogen Sulfide
  MMS High Speed Contaminant Analysis Using Mass Spectrometry with Matrix Deconvolution