Agilent Technologies

List of measurement possibilities for Aromatics

Aromatics
Method Provider Description
ASTM
D2306-96
Agilent
AC
Wasson
C8 Aromatic Hydrocarbons
ASTM
D2360-95e1
Agilent
AC
Wasson
Trace Impurities in Monocyclic Aromatic Hydrocarbons and Total Aromatic Determination
ASTM
D2789-25
MMS Hydrocarbon Types in Low Olefinic Gasoline by Mass Spectrometry
ASTM
D3760-93e1
Agilent
AC
Wasson
Analysis of Isopropylbenzene (Cumene)
ASTM
D3797-96
Agilent
AC
Wasson
Analysis of o-Xylene
ASTM
D3798-96b
Agilent
AC
Wasson
Analysis of p-Xylene
ASTM
D4492-96
Agilent
AC
Wasson
Analysis of Benzene
ASTM
D4534
Wasson
Agilent
Benzene Content of Cyclic Products
ASTM
D4735-96
Agilent
AC
OI
Wasson
Trace Thiophene in Refined Benzene
ASTM
D5060-95
Agilent
AC
Wasson
Impurities in High-Purity Ethylbenzene
ASTM
D5134-92
AC
SSI
Wasson
Detailed Analysis of Petroleum Naphtha through n-Nonane by Capillary GC
ASTM
D5135-95
Agilent
AC
Wasson
Styrene Analysis
ASTM
D5399-95
SSI
Wasson
Boiling Point Distribution of Hydrocarbon Solvents
ASTM
D5623-94
Agilent
AC
Sievers
Sulfur Compounds in Light Petroleum Liquids by GC and Sulfur Selective Detection
ASTM
D5713-96
Agilent
AC
Analysis of High-Purity benzene for Cyclohexane Feedstock by Capillary GC
ASTM
D5769-95
Agilent
AC
Wasson
Determination of Benzene, Toluene and Total Aromatics in Finished Gasoline by GC/MS
ASTM
D5917
Agilent
AC
Trace Impurities in Monocyclic Aromatic Hydrocarbons by GC and external calibration
ASTM
D5917-96
Wasson Trace Impurities in Monocyclic Aromatic Hydrocarbons by GC and external calibration
ASTM proposed Sievers Determination of Thiophene in Benzene
  Agilent High Speed Simulated Distillation of Light Hydrocarbons, Gasoline and Gasoline Feedstocks
  Agilent High Speed Detailed Hydrocarbon Analysis of Non-Oxygenated Gasoline and Hydrocarbon Liquids
  Agilent Sulfur and Nitrogen Compounds in Gasoline through Diesel Range Liquids by GC-AED
  Agilent Multi-Element Analysis of Heteroatomic Compounds in Gasoline through Diesel Range Liquids by GC-AED - C, H, S, N, F, O, Pb, and Mn compounds measured with GC-Atomic Emission Detection
  Agilent Aromatic Hydrocarbon Analysis
  AC High Speed Detailed Hydrocarbon Analysis of Non-Oxygenated Gasoline and Hydrocarbon Liquids
  Sievers Sulfur Simulated Distillation of Petrochemical Products by Gas Chromatography and Chemiluminescence Detection
  Sievers Simultaneous Nitrogen and Hydrocarbon Analysis by GC with Flame Ionization and Chemiluminescence Detection in Light Petroleum Liquids
  Antek Simultaneous Nitrogen, Sulfur and Carbon Determination in Light Petroleum Liquids by GC-Chemiluminescence and Flame Ionization Detection
  Antek Nitrogen, Sulfur and Carbon Distribution in Distillates by GC-Chemiluminescence and Flame Ionization Detection
 Sievers Total Sulfur Analysis in Liquid Fuels by GC with Sulfur Chemiluminescence
 MMS High Speed Contaminant Analysis Using Mass Spectrometry with Matrix Deconvolution
 MMS Aromatic and Saturate Types in Petroleum Distillates