Kerosene
Method Provider Description
ASTM
D2887-97
AC
SSI
Boiling Range Distribution of Petroleum Fractions
ASTM
D2425-93
MMS Hydrocarbon Types in Middle Distillates by Mass Spectrometry
ASTM
D2887
AC
Wasson
High Speed Simulated Distillation of Petroleum fractions boiling up to 538°C - Fast ASTM D 2887
ASTM
D6352
AC Boiling Range Distribution of Petroleum Distillates in boiling range from 174 - 700°C by gas chromatography
IP 343/80(93) Agilent 2,4-Dimethyl-6-tertiary-butylphenol (24M6B) Content of Aviation Turbine Fuel by HPLC
IP 406/95 AC Determination of Boiling Range Distribution of Petroleum Products
IP 424/96 Agilent Fuel System Icing Inhibitor in Aviation Turbine Kerosines by HPLC
IP PM-CF/98 AC Boiling Range Distribution of Petroleum Distillates in boiling range from 174 - 700°C by gas chromatography
ISO
3924
AC
Wasson
Determination of Boiling Range Distribution of Petroleum Products
DIN
51.435
part 1
AC Determination of Boiling Range Distribution of Petroleum Products
  Agilent
AC
SSI
High Speed Simulated Distillation of Petroleum fractions boiling up to 538 °C
  Agilent Dyes in Diesel Fuel
  Sievers Sulfur Simulated Distillation of Petrochemical Products by Gas Chromatography and Chemiluminescence Detection
  Sievers Analysis of Jet and other Distillate Fuels by Simultaneous GC-FID/SCD
  Sievers Simultaneous Nitrogen and Hydrocarbon Analysis by GC with Flame Ionization and Chemiluminescence Detection in Light Petroleum Liquids
  Antek Sulfur Compounds in Distillates by GC-Chemiluminescence Detection
  Antek Simultaneous Sulfur and Carbon Distribution in Mid-distillates Under D 2887 SimDis Conditions by GC-Chemiluminescence and Flame Ionization Detection
  Antek Sulfur Distribution in Petroleum Distillates by Simultaneous HPLC-UV and Chemiluminescence Detection
  Antek Nitrogen, Sulfur and Carbon Distribution in DIstillates by GC-Chemiluminescence and Flame Ionization detection
  SSI Sulfur and Carbon Distribution in Light Petroleum Products by Simultaneous GC-FID and GC-Sulfur Specific Detection
  OI Low level S analysis -ppm to sub-ppb
  SSI Analysis of Paraffins in Kerosene (C5-C20) by Subtractive Gas Chromatography
  Sievers Total Sulfur Analysis in Liquid Fuels by GC with Sulfur Chemiluminescence