Agilent Technologies

List of measurement possibilities for Diesel

Email a Page

*Required fields are marked with a red dot and are in bold text.

*Recipient's Email Address:
Separate multiple addresses using a semi-colon (;).
Your Name:
*Your Email Address:
Comments:
Please be assured that your name, comments and the email addresses you provide will not be used for any other purpose than to complete this forwarding transaction.
   

The following will be sent with your comments


Diesel
Method Provider Description
ASTM
D2887-97
AC
SSI
Boiling Range Distribution of Petroleum Fractions
ASTM
D2425-93
MMS Hydrocarbon Types in Middle Distillates by Mass Spectrometry
ASTM
D2887
AC
Wasson
High Speed Simulated Distillation of Petroleum fractions boiling up to 538°C - Fast ASTM D 2887
ASTM
D6352
AC Boiling Range Distribution of Petroleum Distillates in boiling range from 174 - 700°C by gas chromatography
IP 391/95 Agilent
AC
Aromatic Hydrocarbon Types in Diesel Fuels and Distillates by HPLC
IP 406/95 AC
Wasson
Determination of Boiling Range Distribution of Petroleum Products
IP PM-CF/98 AC Boiling Range Distribution of Petroleum Distillates in boiling range from 174 - 700°C by gas chromatography
ISO
3924
AC
Wasson
Determination of Boiling Range Distribution of Petroleum Products
DIN
51.435
part 1
AC Determination of Boiling Range Distribution of Petroleum Products
  Agilent
AC
SSI
High Speed Simulated Distillation of Petroleum fractions boiling up to 538 °C
  Agilent Dyes in Diesel Fuel
  Sievers Sulfur Simulated Distillation of Petrochemical Products by Gas Chromatography and Chemiluminescence Detection
  Sievers Analysis of Jet and other Distillate Fuels by Simultaneous GC-FID/SCD
  Sievers Simultaneous Nitrogen and Hydrocarbon Analysis by GC with Flame Ionization and Chemiluminescence Detection in Light Petroleum Liquids
  Antek Simultaneous Sulfur and Carbon Distribution in Mid-distillates Under D 2887 SimDis Conditions by GC-Chemiluminescence and Flame Ionization Detection
  Antek Sulfur Distribution in Petroleum Distillates by Simultaneous HPLC-UV and Chemiluminescence Detection
  Antek Nitrogen, Sulfur and Carbon Distribution in DIstillates by GC-Chemiluminescence and Flame Ionization detection
  SSI Sulfur and Carbon Distribution in Light Petroleum Products by Simultaneous GC-FID and GC-Sulfur Specific Detection
 Sievers Total Sulfur Analysis in Liquid Fuels by GC with Sulfur Chemiluminescence



© Agilent 2002-2005